If NO end positions are set, the product will move in the pulse / step operation. Go then to STEP 3.
If end positions are set, the product will continue to its end position. Go then to STEP 5.
WARNING: It is possible that the correct end positions have not been set. Go then to OPTION A.
Establishing connection
Step 2
In the procedures described here is a maximum interval of 10 seconds to complete each
subsequent action: if you wait any longer, the system will leave the edit mode.
Normally a button only needs to be pressed shortly. If you need to press and hold a button for
several seconds this will be state clearly.
The system will confirm each completed step with moving the blind up and down ( ).
If a procedure does not play out as described, wait for 20 seconds and start again
from the beginning of that step/procedure.
STOP
Press the P1 button Press the STOP button Transmitter/ channel
has been added
LED blinks
1x
Release the
button
LED blinks
5x
Page 5
Adjusting the direction of rotation (Only if the direction of rotation is not correct)
Step 3
Only possible if no end positions are set.
Press ±10 sec. P1 Release P1 when LED Flashes The direction of rotation is
changed successfully
LED Flashes
5x Beeps 3x
Setting the End Limits
Step 4
Press 1x
OPEN Button The curtain opens and
will in the end automatically
stop and save the setting
The curtain
closes and stop.
LED Flashes
5x Beeps 3x
Press 1x
CLOSE Button End positions
are set
The curtains are now ready for use.
If you are not satisfied with the result of setting the end positions, go to Option A - adjusting positions
or Resetting factory settings.