Bosch DVR-3000 User manual

DIVAR 3000/5000 Digital Video Recorder
DVR-3000/5000
en Operator Manual


Table of contents
1Safety 7
1.1 Safety precautions 7
1.2 Important safety instructions 7
1.3 Important Notices 9
1.4 FCC and UL 11
1.5 Bosch notices 11
2Short information 13
2.1 960H high resolution 13
2.2 Compression technology 13
3Introduction 14
3.1 Digital video recorder applications 14
3.1.1 Versions 14
3.1.2 Manuals 14
3.1.3 Features 15
3.2 Unpacking 15
3.2.1 Package contents 15
3.3 Installation environment 16
3.3.1 Mounting 16
3.3.2 Ventilation 16
3.3.3 Temperature 16
3.3.4 Power Supply 16
3.3.5 Environment 16
3.4 Associated equipment 16
3.5 Warranty 16
4Quick install 17
4.1 Connections 17
4.1.1 Primary connections 19
4.1.2 Optional connections 19
4.2 Powering up 20
4.3 Login 21
4.4 Startup Wizard 21
4.4.1 Reset startup wizard 23
4.4.2 General 23
4.4.3 Encoder 24
4.4.4 Schedule 25
4.4.5 Record 25
4.4.6 Network 26
4.5 Shutdown/Logout 26
5Hardware setup 28
5.1 Camera connections 28
5.2 Audio connections 28
5.3 Monitor connections 28
5.3.1 VGA output 28
5.3.2 CVBS 29
5.3.3 HDMI 29
5.4 Keyboard connection (only DIVAR 5000) 29
5.5 Ethernet connection 30
DIVAR 3000/5000 Digital Video
Recorder Table of Contents | en 3
Bosch Security Systems Operator Manual 2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder

5.6 RS485 port connection 31
5.7 RS232 port connections 31
5.8 USB connectors 32
5.9 e-SATA connector (only DIVAR 5000) 32
5.10 Alarm I/O connections 33
5.10.1 Connecting the alarm input 33
5.10.2 Connecting the alarm output 34
5.11 Power supply 34
6Configuration 35
6.1 Setting 36
6.2 General 37
6.3 Encode 39
6.3.1 Overlay 40
6.3.2 Snapshot 40
6.3.3 Copy 41
6.4 Schedule 43
6.5 Serial port 45
6.6 Network 46
6.6.1 Network settings 47
6.6.2 IP filter 48
6.6.3 NTP 49
6.6.4 PPPoE 49
6.6.5 DDNS 50
6.6.6 UPnP 51
6.6.7 EMail 52
6.6.8 FTP server 53
6.6.9 SNMP 54
6.7 Alarm 55
6.8 Detect 57
6.8.1 Motion detect region setup 59
6.8.2 Period 60
6.8.3 PTZ activation 61
6.9 Pan/Tilt/Zoom 62
6.10 Display 63
6.10.1 Tour setup 64
6.11 Default 65
6.12 Advanced 66
6.13 Hard Disk (HDD) 67
6.14 System events 68
6.15 Alarm Output 69
6.16 Record 70
6.17 Account/Users 71
6.17.1 Add user 72
6.17.2 Modify/Delete a user 73
6.17.3 Modify password 74
6.18 Auto maintain 75
6.19 TV adjust 76
6.20 Text data overlay 77
6.21 Configuration/Backup 79
4en | Table of Contents DIVAR 3000/5000 Digital Video
Recorder
2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder
Operator Manual Bosch Security Systems

6.22 Sequence Mon B 79
7Operating instructions 80
7.1 User controls and menus 80
7.1.1 Mouse Controls 81
7.1.2 Front panel controls 82
7.1.3 Remote control 85
7.1.4 Quick menu 87
7.1.5 Main menu 88
7.2 Live and playback 89
7.2.1 Live mode 90
7.2.2 PTZ 92
7.2.3 Sequence 92
7.2.4 Monitor A 93
7.2.5 Monitor B 93
7.3 Search/Play 93
7.4 Backup 98
7.5 Info 101
7.5.1 HDD info 102
7.5.2 Bps 103
7.5.3 Log 104
7.5.4 Version 105
7.5.5 Online users 106
7.5.6 Network info 106
7.6 Triggers and alarms 108
8Web Client Software 110
8.1 Getting started 110
8.1.1 System requirements 110
8.1.2 Connecting to the DIVAR the first time 111
8.2 How to log on 111
8.2.1 Menu structure differences 114
8.3 Introducing the Web Live window 114
8.3.1 Playback mode 116
8.3.2 Setup mode 116
8.3.3 Alarm 117
8.3.4 About 118
8.3.5 Logout 118
9Archive Player operation 119
9.1 Getting started 119
9.1.1 System requirements 119
9.1.2 Installation 119
9.1.3 Starting the Player 119
9.1.4 Setting 122
9.2 Camera Views 125
9.3 Checking authenticity (Watermark) 125
9.4 Exit button 126
10 Troubleshooting 127
11 Maintenance 131
11.1 Attach ESD strap 134
11.2 Replace internal battery 134
DIVAR 3000/5000 Digital Video
Recorder Table of Contents | en 5
Bosch Security Systems Operator Manual 2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder

11.3 Install HDD in DIVAR 3000 135
11.4 Install HDD in DIVAR 5000 138
11.5 Install DVD in DIVAR 3000 142
11.6 Install DVD in DIVAR 5000 144
12 Technical specifications 146
12.1 DIVAR 3000 146
12.2 DIVAR 5000 149
12.3 Standards and Directives 153
13 Appendix 155
13.1 Software licenses 155
13.1.1 Bosch software 155
13.1.2 Other licenses — copyright notices 155
13.1.3 Warranties and disclaimer of warranties 156
13.2 DVD compatibility 156
13.3 USB memory sticks 157
13.4 HDD compatibility 158
6en | Table of Contents DIVAR 3000/5000 Digital Video
Recorder
2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder
Operator Manual Bosch Security Systems

Safety
This safety section describes safety requirements and the format used for warnings and
cautions.
Safety precautions
Warnings and caution formats
Danger!
High risk: This symbol indicates an imminently hazardous situation such as "Dangerous
Voltage" inside the product.
If not avoided, this will result in an electrical shock, serious bodily injury, or death.
!
Warning!
Medium risk: Indicates a potentially hazardous situation.
If not avoided, this could result in minor or moderate bodily injury.
!
Caution!
Low risk: Indicates a potentially hazardous situation.
if not avoided, this could result in property damage or risk of damage to the unit.
Notice!
This symbol indicates information or a company policy that relates directly or indirectly to the
safety of personnel or protection of property.
Important safety instructions
Read, follow, and retain for future reference all of the following safety instructions. Heed all
warnings on the unit and in the operating instructions before operating the unit.
1. Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions
provided with the unit. Generally, using a dry cloth for cleaning is sufficient but a moist,
fluff-free cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol
cleaners.
2. Heat Sources - Do not install the unit near any heat sources such as radiators, heaters,
stoves, or other equipment (including amplifiers) that produce heat.
3. Ventilation - Any openings in the unit enclosure are provided for ventilation to prevent
overheating and ensure reliable operation. Do not block or cover these openings. Do not
place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's
instructions have been adhered to.
4. Water - Do not use this unit near water, for example near a bathtub, washbowl, sink,
laundry basket, in a damp or wet basement, near a swimming pool, in an outdoor
installation, or in any area classified as a wet location. To reduce the risk of fire or
electrical shock, do not expose this unit to rain or moisture.
5. Object and liquid entry - Never push objects of any kind into this unit through openings
as they may touch dangerous voltage points or short-out parts that could result in a fire
or electrical shock. Never spill liquid of any kind on the unit. Do not place objects filled
with liquids, such as vases or cups, on the unit.
1
1.1
1.2
DIVAR 3000/5000 Digital Video
Recorder Safety | en 7
Bosch Security Systems Operator Manual 2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder

6. Lightning - For added protection during a lightning storm, or when leaving this unit
unattended and unused for long periods, unplug the unit from the wall outlet and
disconnect the cable system. This will prevent damage to the unit from lightning and
power line surges.
7. Controls adjustment - Adjust only those controls specified in the operating instructions.
Improper adjustment of other controls may cause damage to the unit. Use of controls or
adjustments, or performance of procedures other than those specified, may result in
hazardous radiation exposure.
8. Overloading - Do not overload outlets and extension cords. This can cause fire or
electrical shock.
9. Power supply cord and plug protection - Power supply cords should be routed so that
they are not likely to be walked on or pinched by items placed upon or against them,
playing particular attention to cords and plugs, convenience receptacles, and the point
where they exit from the appliance.
10. Power disconnect - Units have power supplied to the unit whenever the power cord is
inserted into the power source. The power cord plug is the main power disconnect device
for switching off the voltage for the unit.
11. Power sources - Operate the unit only from the type of power source indicated on the
label. Before proceeding, be sure to disconnect the power from the cable to be installed
into the unit.
12. Servicing - Do not attempt to service this unit yourself. Opening or removing covers may
expose you to dangerous voltage or other hazards. Refer all servicing to qualified service
personnel.
13. Damage requiring service - Unplug the power unit from the main AC power source and
refer servicing to qualified service personnel when any damage to the equipment has
occurred, such as:
–the power supply cord or plug is damaged;
– exposure to moisture, water, and/or inclement weather (rain, snow, etc.);
– liquid has been spilled in or on the equipment;
– an object has fallen into the unit;
– unit has been dropped or the unit cabinet is damaged;
– unit exhibits a distinct change in performance;
– unit does not operate normally when the user correctly follows the operating
instructions.
14. Replacement parts - Be sure the service technician uses replacement parts specified by
the manufacturer, or that have the same characteristics as the original parts.
Unauthorized substitutions could void the warranty and cause fire, electrical shock, or
other hazards.
15. Safety check - Safety checks should be performed upon completion of service or repairs
to the unit to ensure proper operating condition.
16. Installation - Install in accordance with the manufacturer's instructions and in accordance
with applicable local codes.
17. Attachments, changes or modifications - Only use attachments/accessories specified by
the manufacturer. Any change or modification of the equipment, not expressly approved
by Bosch, could void the warranty or, in the case of an authorization agreement, authority
to operate the equipment.
8en | Safety DIVAR 3000/5000 Digital Video
Recorder
2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder
Operator Manual Bosch Security Systems

Important Notices
Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The
unit may fall, causing serious injury and/or serious damage to the unit. Use only with the
cart, stand, tripod, bracket, or table specified by the manufacturer. When a cart is used, use
caution and care when moving the cart/apparatus combination to avoid injury from tip-over.
Quick stops, excessive force, or uneven surfaces may cause the cart/unit combination to
overturn. Mount the unit per the manufacturer's instructions.
All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at
least 3 mm in each pole, into the electrical installation of the building. If it is needed to open
the housing for servicing and/or other activities, use this all-pole switch as the main
disconnect device for switching off the voltage to the unit.
Battery replacement - For qualified service personnel only - A lithium battery is located
inside the unit enclosure. To avoid danger of explosion, replace the battery as per
instructions. Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of the replaced battery in an environmentally friendly way and not with
other solid waste. Refer all servicing to qualified service personnel.
Notice!
Batteries must not be disposed of in household waste. Dispose of batteries only at suitable
collection points and, in the case of lithium batteries, mask the poles.
For further information refer to: http://www.BoschSecurity.com/standards
!
Caution!
Class I Laser Product
Invisible laser radiation when open. Avoid exposure to beam.
Coax grounding:
–Ground the cable system if connecting an outside cable system to the unit.
– Connect outdoor equipment to the unit's inputs only after this unit has had its grounding
plug connected to a grounded outlet or its ground terminal is properly connected to a
ground source.
– Disconnect the unit's input connectors from outdoor equipment before disconnecting the
grounding plug or grounding terminal.
– Follow proper safety precautions such as grounding for any outdoor device connected to
this unit.
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides
information regarding proper grounding of the mount and supporting structure, grounding of
the coax to a discharge unit, size of grounding conductors, location of discharge unit,
connection to grounding electrodes, and requirements for the grounding electrode.
Disposal - Your Bosch product was developed and manufactured with high-quality material
and components that can be recycled and reused. This symbol means that electronic and
electrical appliances, which have reached the end of their working life, must be collected
and disposed of separately from household waste material. Separate collecting systems are
usually in place for disused electronic and electrical products. Please dispose of these units
at an environmentally compatible recycling facility, per European Directive 2002/96/EC.
1.3
DIVAR 3000/5000 Digital Video
Recorder Safety | en 9
Bosch Security Systems Operator Manual 2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder

!
Caution!
Electronic Surveillance - This device is intended for use in public areas only.
U.S. federal law strictly prohibits surreptitious recording of oral communications.
Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid
electrostatic discharge. NOTE: Wear required grounded wrist straps and observe proper ESD
safety precautions when handling the electrostatic-sensitive printed circuit boards.
Environmental statement - Bosch has a strong commitment towards the environment. This
unit has been designed to respect the environment as much as possible.
Fuse rating - For protection of the device, the branch circuit protection must be secured with
a maximum fuse rating of 16 A. This must be in accordance with NEC800 (CEC Section 60).
Grounding and polarization - This unit may be equipped with a polarized alternating current
line plug (a plug with one blade wider than the other blade). This safety feature allows the
plug to fit into the power outlet in only one way. If unable to insert the plug fully into the
outlet, contact a locally certified electrician to replace the obsolete outlet. Do not defeat the
safety purpose of the polarized plug.
Alternately, this unit may be equipped with a 3-pole grounding plug (a plug with a third pin for
earth grounding). This safety feature allows the plug to fit into a grounded power outlet only.
If unable to insert the plug into the outlet, contact a locally certified electrician to replace the
obsolete outlet. Do not defeat the safety purpose of the grounding plug.
Moving - Disconnect the power before moving the unit. Move the unit with care. Excessive
force or shock may damage the unit and the hard disk drives.
Outdoor signals - The installation for outdoor signals, especially regarding clearance from
power and lightning conductors and transient protection, must be in accordance with NEC725
and NEC800 (CEC Rule 16-224 and CEC Section 60).
Permanently connected equipment - Incorporate a readily accessible disconnect device
external to the equipment.
Pluggable equipment - Install the socket outlet near the equipment so it is easily accessible.
Rack-mount (only DIVAR 5000 family)
–Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by the
manufacturer.
– Reduced Air Flow - Installation of the equipment in a rack should be such that the amount
of air flow required for safe operation of the equipment is not compromised.
– Mechanical loading - Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
– Circuit Overloading - Consideration should be given to the connection of the equipment
to the supply circuit and the effect that overloading of the circuits might have on
overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
– Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections
to the branch circuit (e.g. use of power strips).
SELV - All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits
should only be connected to other SELV circuits.
10 en | Safety DIVAR 3000/5000 Digital Video
Recorder
2013.05 | 1.0 | DIVAR 3000/5000 Digital Video
Recorder
Operator Manual Bosch Security Systems
This manual suits for next models
3
Table of contents
Other Bosch DVR manuals

Bosch
Bosch DVR 670 Series User manual

Bosch
Bosch DIVAR 2000 User manual

Bosch
Bosch DVR4C1161 User manual

Bosch
Bosch DVR4C Series Instructions for use

Bosch
Bosch DVR 440 User manual

Bosch
Bosch DIVAR IP 7000 User manual

Bosch
Bosch DIVAR AN 3000 User manual

Bosch
Bosch DVR1A1081 User manual

Bosch
Bosch 430 Series User manual

Bosch
Bosch DVR4C Series User manual

Bosch
Bosch DVR1A Series User manual

Bosch
Bosch DVR4C1161 User manual

Bosch
Bosch DVR-451-04A050 User manual

Bosch
Bosch NetDVR User manual

Bosch
Bosch DESAXL User manual

Bosch
Bosch Divar IP 5000 User manual

Bosch
Bosch Eazeo User manual

Bosch
Bosch DVR1A1081 User manual

Bosch
Bosch 600 Series Instructions for use

Bosch
Bosch EN User manual