BMC iVolve N2 User manual


English
iVolve N2 Nasal Mask
User Manual
0123

iVolve N2 Nasal Mask User Manual V2.0
English
Table of Contents
iVolve N2 Nasal Mask ......................................................................1
Intended Use....................................................................................1
Before Using the Mask.....................................................................2
Parts of the Mask .............................................................................3
Fitting the Mask................................................................................4
Disassembling the Mask ..................................................................5
Getting the Right Cushion Size........................................................5
Cleaning the Mask in the Home.......................................................6
Reprocessing the Mask between Patients.......................................7
Reassembling the Mask...................................................................8
Troubleshooting................................................................................9
Technical Specifications .................................................................10
Storage...........................................................................................11
Disposal..........................................................................................11
Symbols..........................................................................................11
Limited Warranty............................................................................12

iVolve N2 Nasal Mask User Manual V2.0
1 / 12
English
iVolve N2 Nasal Mask
Thank you for choosing BMC’s iVolve N2 Nasal Mask (BMC-NM2).
The Nasal Mask is comfortable, flexible and quiet. It is designed to
minimize contact with your face, thus ensuring that you feel
comfortable during therapy. This user guide provides you with the
information you need for the correct use of your mask.
Intended Use
The iVolve N2 channels airflow noninvasively to a patient from a
positive airway pressure device such as a continuous positive
airway pressure (CPAP) or Bi-level system.
The iVolve N2 is:
•To be used by adult patients (> 30 kg) for whom positive airway
pressure has been prescribed.
•Intended for single-patient re-use in the home environment and
multi-patient re-use in the hospital / institutional environment.
CAUTION: Federal law restricts the sale of this device to sale by or
on the order of a physician.

iVolve N2 Nasal Mask User Manual V2.0
2 / 12
English
Before Using the Mask
WARNINGS
The vent holes must be kept clear.
Follow all precautions when using supplemental oxygen.
Oxygen flow must be turned off when the flow generator is not
operating, so that unused oxygen does not accumulate within
the flow generator enclosure and create a risk of fire.
At a fixed flow rate of supplemental oxygen flow, the inhaled
oxygen concentration varies, depending on the pressure
settings, patient breathing pattern, mask, point of application
and leak rate.
The technical specifications of the mask are provided for your
clinician to check if they are compatible with the flow generator.
If used outside specification or if used with incompatible
devices, the seal and comfort of the mask may not be effective,
optimum therapy may not be achieved, and leak, or variation in
the rate of leak, may affect the flow generator function.
Stop using the iVolve N2 if you have ANY adverse reaction to
the use of the mask, and consult your physician or sleep
therapist.
Refer to your flow generator manual for details on settings and
operational information.

iVolve N2 Nasal Mask User Manual V2.0
3 / 12
English
Parts of the Mask
Construction of the iVolve N2 Nasal Mask

iVolve N2 Nasal Mask User Manual V2.0
4 / 12
English
Fitting the Mask
1
2
3
Attach the headgear
straps by threading
them through the
gaps of forehead
frame and clips.
Hold the mask over
your nose and pull
the headgear over
your head.
Bringing the lower
straps below your
ears, connect the
clips to the main
frame.
4
5
6
Adjust the headgear
straps evenly until
they are comfortable
and firm, and reattach
the mask.
Adjust the main frame
until the mask is
evenly positioned on
your face. It should
be comfortable, with
an effective seal.
Adjust the headgear
straps if necessary.
Connect the main air
tubing to the swivel
directly. Then connect
the free end of the air
tubing to your flow
generator and turn
the flow generator on.

iVolve N2 Nasal Mask User Manual V2.0
5 / 12
English
Disassembling the Mask
1
2
3
Detach the air tubing.
Unclip the clips and
unthread the upper
headgear straps. It is
not necessary to
remove the clips from
the headgear.
Remove the forehead
pads from the
forehead frame.
Remove the cushion
assembly from the
mask frame.
Getting the Right Cushion Size
The following drawings are the different features of face. The
length of the nose is “N1”, and the width of the nose is “N2”.
There are masks in three different sizes provided for
comfortable therapy. “S”, “M”and “L”represent Small, middle
and large, respectively.
The mask cushion is designed shaping with men’s nose, when
the dimensions of patient’s nose are equal with the mask, the
mask will fit the nose at the most fit place. Otherwise, he should
choose another size.
Choose the smallest size mask cushion that is wide enough to
extend beyond the nostrils but does not obstruct breathing.

iVolve N2 Nasal Mask User Manual V2.0
6 / 12
English
Dimensions of Face and the Mask
Cleaning the Mask in the Home
Notes:
The mask and headgear can only be cleaned by handwashing.
The headgear may be washed without removing the clips.
CAUTION
Do not use solutions containing bleach, chlorine, alcohol,
aromatics, moisturizers, antibacterial agents, or scented oils to
clean any part of the system or air tubing. These solutions may
cause damage and reduce the life of the product.
Exposing any part of the system or tubing to direct sunlight or
heat may cause deterioration.
If any visible deterioration of a component is apparent (cracking,
crazing, tears etc), the component should be discarded and
replaced.

iVolve N2 Nasal Mask User Manual V2.0
7 / 12
English
Daily/After Each Use
To optimize the mask seal, facial oils should be removed from the
cushion before use.
Handwash the mask by gently rubbing in warm (30°C) water using
mild soap or diluted dishwashing detergent.
If the pick-off port cover requires cleaning use a soft bristle brush.
Rinse all components well with drinking quality water and allow
them to air dry out of direct sunlight. Do not soak the mask.
Weekly
Handwash the headgear and all components in warm, (approx.
30°C) and soapy water. Use pure soap. Rinse the components well
and allow them to air dry out of direct sunlight.
Reprocessing the Mask between Patients
This mask should be reprocessed when used between patients.
Cleaning and disinfection instructions are available from the BMC
website, www.bmc-medical.com. If you do not have internet access,
please contact your BMC representative.
This manual suits for next models
1
Table of contents
Languages:
Other BMC Respiratory Product manuals

BMC
BMC REACTHEALTH Luna G3 APAP User manual

BMC
BMC G2S A20 User manual

BMC
BMC Rio II User manual

BMC
BMC 3B RESmart BPAP 25A User manual

BMC
BMC 3B Siesta User manual

BMC
BMC REACTHEALTH NUMA User manual

BMC
BMC F2 User manual

BMC
BMC REACTHEALTH Siesta User manual

BMC
BMC REACTHEALTH Luna G3 BPAP 25A User manual