Bluedri BD-LGR75C User manual

LGR Dehumidifier Owner’s Manual
115v Model: BD-LGR75C
Please read this owner’s manual
before operating and keep
safe for future reference

- 1 -
GENERAL INFORMATION
Thank you for choosing our LGR Dehumidifier
This Owner’s Manual will provide you with valuable
information necessary for the proper care and maintenance of
your new dehumidifier.
Please take a few moments to read the instructions thoroughly
and familiarize yourself with all the features and operation of
this dehumidifier.
Unpackaging the dehumidifier
Please do not dispose of any packaging until you have checked
the appliance is operational.
After removing the packaging ensure the contents are intact
and complete. In the unlikely event of missing parts; contact
your retailer.
Do not leave children unattended with any of the packaging
since it is a potential source of danger. Disposal of all packaging
must be carried out responsibly & safely and in accordance
you’re your local authority regulations.
Always recycle the packaging material where possible.When
using any electrically powered product, basic safety precautions
should always be followed.
PLEASE READ THESE INSTRUCTIONS CAREFULLY
BEFORE USING THE PRODUCT.

- 2 -
When using any electrical appliance,
Basic safety precautions should always be followed.
IMPORTANT INSTRUCTIONS
WARNING - to reduce the risk of fire, electrical shock or injury
to persons or property:
1Always operate the product from a power source of the
same voltage, frequency and rating as indicated on the
product identification plate.
2Close supervision is necessary when any product is used by
or near children the elderly or the infirm. Do not allow
children to use the appliance as a toy.
3This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities or lack of experience and knowledge unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their
safety.
4Do not operate any product with a damaged power cord or
plug, after the product malfunctions, dropped or damaged
in any way. Return the complete product to the place of
purchase for inspection, repair or replacement.
5To reduce the risk of electric shock, do not expose the unit
or flexible cord to moisture of any kind.
6Switch off and unplug from the power socket when not in
use, before assembling or before cleaning.

- 3 -
IMPORTANT INSTRUCTIONS
7Do not place objects on the product or allow objects to
obstruct the inlet or outlet openings, or operate in close
proximity to walls or curtains, etc.
8The use of attachments or accessories not recommended
or sold by the product distributor may cause injury to
persons or damage to property.
9Do not attempt to dismantle the appliance.
10 Do not operate the appliance on a metal surface.
11 Do not use the appliance in artificially hot or humid
conditions or allow to be used in a hazardous environment.
Consult the product Specifications section for approved
operating conditions.
12 Do not clean the appliance with organic solvent.
13 This Owner’s Manual is an integral part of the appliance
and should be stored for safe keeping and must always
accompany the appliance in the event of ownership
transfer or for reference to by a service engineer.
Typical 3 prong
plug and outlet

- 4 -
Control panel
Filters
Air intake
metal grill
Water pipe
Storage location
Water
pipe
Water pipe Connector
(Female)
Pull rod
Rating label
Wheel
PRODUCT IDENTIFICATION
Domed decal
Air outlet
Power cord
fixed support
Power
cord
Water pipe
connector
(male)
FIG.A: FRONT
FIG.B: REAR

- 5 -
SETTING UP INSTRUCTIONS
SETTING UP THE DEHUMIDIFIER
WARNING
No not obstruct the air intake or air outlet
IMPORTANT
Place dehumidifier in the upright position. When
transporting a dehumidifier to site, allow the
dehumidifier to stand for 30 minutes before switching
ON. This is necessary to allow the refrigerant system to
stabilize and avoid system damage.
PLACE IN ENCLOSED AREA: For best results, operate the
dehumidifier in an enclosed area to create a "drying chamber."
Close all doors and windows that open to external areas to
maximize the dehumidifier’s water removal efficiency. Keep
traffic through the drying chamber to a minimum. Place the
dehumidifier in the center of the room away from walls and
furnishings where airflow may be obstructed.
PROPER AIRFLOW IS ESSENTIAL: Do not place this dehumidifier
in a position where the front Air Intake Grill or rear Air Outlet is
blocked by walls, furniture or any other obstruction.

- 6 -
Air Outlet
Attach Ductwork
16.5FT. MAXIMUM
Front Air
Intake Grill
SETTING UP INSTRUCTIONS
Illustration of correct positioning for best performance
ENSURE PROPER ATTACH DUCTWORK: This dehumidifier can
attach diameter 0.558 foot air outlet ductwork to satisfy the
needs of different places. To avoid airflow restrictions , Do not
attach exceed a 16.5 foot length ductwork, the ductwork
ensure do not winding .
.
KEEP CLEAR AND
NO NOT WINDING
KEEP CLEAR

- 7 -
SETTING UP INSTRUCTIONS
ENSURE PROPER DRAINAGE: This dehumidifier contains a
built-in pump that connects to a drainage hose which is stored
in the back of the unit. Uncoil the entire hose to ensure that
there are no kinks or restrictions and place the unattached end
into a drain or run to the outdoors. Ensure that water piped to
the outdoors does not create a slipping hazard. To avoid
damaging or overworking the pump, do not exceed a 10 foot
vertical lift height between the pump and drain.
10 FT. MAXIMUM
DRAIN HEIGHT
To Drain
Rear Drain
Hose Outlet
Drain
Hose

- 8 -
CONTROL PANEL
Digital Control Panel
ON/OFF: Press once to turn the unit ON or OFF.
PURGE: Press the “PURGE”key to empty water
from the pump reservoir. During normal operation the
pump purges automatically when the reservoir is full. Use
“PURGE” before moving the machine to avoid water
spillage. The pump will close automatically after forty
seconds continuous operation.
FUNCTION: Press the “FUNCTION”key, The screen
will display ‘Humidity setting’ ‘Ambient humidity’ ‘Total
running hours’ ‘Ambient temperature’.
REGULATE: Press “REGULATE”key to adjust humidity
or set total running hours and job hours or setting
fahrenheit and centigrade.
Long press “REGULATE”key 5 seconds, The coil sensor
temperature will display. The screen will return to display
ambient humidity after coil sensor temperature cursor
flashing 3 seconds.
Coil Sensor Temperature

- 9 -
CONTROL PANEL
The LCD displays symbols
: Dehumidify ON.
: Defrost ON.
: Draining.
: Fan start up
: Setting humidity.
: Ambient humidity.
: Total running hours.
: Ambient temperature.
Table of contents
Other Bluedri Dehumidifier manuals