Blue Seal Evolution GP514 User manual

GAS GRIDDLE
GP514
GP516
GP518
INSTALLATION AND OPERATION MANUAL
232422-10

The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in
writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and
design without prior notice.
© Copyright Moffat Ltd. April 2012.
MANUFACTURED BY
Moffat Limited
Christchurch
New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited
Web: www.moffat.com.au
E.Mail: [email protected]
Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3833
Service: (tel): 1800 622 216
Spares: (tel): 1800 337 963
Customer Service: (tel): 1800 335 315
(fax): 1800 350 281
CANADA
Serve Canada
Web: www.servecanada.com
E.Mail: [email protected]
Sales: (tel): 800 551 8795 (Toll Free)
Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited
Web: www.moffat.co.nz
E.Mail: [email protected]
Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal
Web: www.blue-seal.co.uk
E.Mail: [email protected]
Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711
Spares: (tel): +44 121 322 6640
(fax): +44 121 327 9201
Service: (tel): +44 121 322 6644
(fax): +44 121 327 6257
UNITED STATES
Moffat
Web: www.moffat.com
Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556
(fax): +1 336 661 9546
Service: (tel): 800 858 4477 (Toll Free)
(tel): +1 336 661 1556
(fax): +1 336 661 1660
REST OF WORLD
Moffat Limited
Web: www.moffat.co.nz
E.Mail: [email protected]

Contents
Blue Seal Gas Griddle
GP514 Gas Griddle, 600mm.
GP516 Gas Griddle, 900mm.
GP518 Gas Griddle, 1200mm.
Introduction ............................................................................................. 2
Specifications ........................................................................................... 3
Model Numbers Covered in this Specification
General
Gas Supply Requirements
Gas Connection
Dimensions ................................................................................................ 5
Installation ................................................................................................ 9
Installation Requirements
Unpacking
Location
Clearances
Assembly
Gas Connection
Commissioning
Operation................................................................................................. 12
Operation Guide
Description of Controls
Lighting Pilot Burner
Lighting Main Burner
Turning ‘Off’ Main Burner / Pilot
Re-Setting Overtemp Device (All UK and Optional Non-UK Models)
Cleaning and Maintenance ...................................................................... 15
General
After Each Use
Daily Cleaning
Weekly Cleaning
Periodic Maintenance
Fault Finding............................................................................................ 18
Gas Conversion and Specifications ......................................................... 19
Conversion Procedure
Gas Specifications
Replacement Parts List ........................................................................... 22

2
Introduction
We are confident that you will be delighted with your BLUE SEAL GAS GRIDDLE, and it will become a most
valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Blue Seal Gas Griddle, there are two important
things you can do.
Firstly:
Please read the instruction book carefully and follow directions given. Time taken will be well spent.
Secondly:
If you are unsure of any aspect of installation, instructions or performance of your appliance, contact
your BLUE SEAL dealer promptly. In many cases a phone call could answer your question.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
THE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
ITIS RECOMMENDED THAT AREGULAR INSPECTION IS MADE BY ACOMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
Warning
This appliance is for professional use and is only to be used by qualified
persons.
Only authorised service persons are to carry out installation, servicing or gas
conversion operations.
Components having adjustments protected (e.g. paint sealed) by the
manufacturer should not be adjusted by the user / operator.
DO NOT operate the appliance without the legs supplied fitted.
Caution
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS
THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
Warning
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN APROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
Warning

3
Specifications
Model Numbers Covered in this Specification
GP514 - B Gas Griddle 600mm wide Bench Model.
GP514 - CB Gas Griddle 600mm wide with Cabinet Base.
GP514 - LS Gas Griddle 600mm wide on Leg Stand.
GP516 - B Gas Griddle 900mm wide Bench Model.
GP516 - CB Gas Griddle 900mm wide with Cabinet Base.
GP516 - LS Gas Griddle 900mm wide on Leg Stand.
GP516 - RB Gas Griddle 900mm wide with Refrigerated Base.
GP518 - B Gas Griddle 1200mm wide Bench Model.
GP518 - CB Gas Griddle 1200mm wide with Cabinet Base.
GP518 - LS Gas Griddle 1200mm wide on Leg Stand.
GP518 - RB Gas Griddle 1200mm wide with Refrigerated Base.
General
A commercial heavy duty, fully modular, gas fired griddle using a thermostatic burner system and
fitted with aluminised steel burners with full pilot and flame failure protection and piezo ignition.
It uses a 20mm thick griddle plate with the option of either ribbed or chromed mirror plate options.
All UK Models and optional Non-UK Models are fitted with an overtemp device which isolates the gas
supply to burners should gas control system or thermostat malfunction, thus preventing overheating
of griddle.
The Griddle is constructed as a hob unit and is available in 4 options, on Leg Stand (-LS), Bench
Mount (-B), Cabinet Base (-CB) or with Refrigerated Base (RB) models (Not available for GP514
Models).

4
Specifications
Gas Supply Requirements
(*) NOTE:
Measure burner operating pressure at gas valve outlet test point with burner operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set, through the appliance reg-
ulator and not to be adjusted, apart from when converting between gases, if required.
TOWN GAS Only - Burner operating pressure is to be adjusted using Town Gas adjustable
gas regulator supplied.
Refer to ‘Gas Conversion and Specifications section in this manual for further details.
(*) - GP514 Town Gas model is available ex-factory on request only.
Gas Connection
Bench Models
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear, 55mm from floor and is reached from rear of appliance. (Refer to
‘Dimensions’ section).
Connection is ¾" BSP male (For all other models).
All Other Models
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 32mm from rear, 655mm from floor and is reached from beneath appliance. (Refer to
‘Dimensions’ section).
Connection is ¾" BSP male (For all other models).
For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation
Manual supplied with appliance.
Natural Gas LP Gas / Butane Town Gas
GP514 GP516 GP518 GP514 GP516 GP518 GP514 GP516 GP518
Input
Rating
(N.H.G.C.)
53 MJ/hr
(50,234 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
53 MJ/hr
(50,234 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
53 MJ/hr
(50,234 BTU)
80 MJ/hr
(75,825 BTU)
108 MJ/hr
(102,364 BTU)
Supply
Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18” w.c.)
0.75 - 1.50 kPa
(3” - 6” w.c.)
Operating
Pressure
0.85 kPa (*)
(3.4” w.c.)
0.90 kPa
(3.6”w.c.)
2.5 kPa
(9.8” w.c.)
2.6 kPa
(10.2” w.c.)
0.35 kPa
(1.4”w.c.)
Gas
Connection ¾” BSP Male
0.45 kPa
(1.8”w.c.)

5
Dimensions
GP514 - B
GP516 - B
GP518 - B
Dimensions for Bench Models
= Rating Plate Location for
this option.
R
R

6
Dimensions
GP514 - CB
GP516 - CB
GP518 - CB
Dimensions for Cabinet Base Models
= Rating Plate Location for
this option.
R
R

7
Dimensions
GP514 - LS
GP516 - LS
GP518 - LS
Dimensions for Leg Stand Models
= Rating Plate Location for
this option.
R
R

8
Dimensions
GP516 - RB
GP518 - RB
Dimensions for Refrigeration Base Models
= Rating Plate Location for
this option.
R
R
280
Other manuals for Evolution GP514
1
This manual suits for next models
2
Table of contents
Other Blue Seal Griddle manuals
Popular Griddle manuals by other brands

Keating Of Chicago
Keating Of Chicago MIRACLEAN PRE-2000 manual

Nexgrill
Nexgrill 720-0786A owner's guide

Outwell
Outwell FH-3047C instruction manual

Rankam
Rankam Member's Mark GR2298901-MM-02 Assembly & operating instructions

Black Stone
Black Stone 1972 owner's manual

Star
Star Ultra Max 760TA Installation and operation instructions