Blu Stream ACM500 User manual

ACM500 QUICK REFERENCE GUIDE
01Contact: support@blustream.com.au|support@blustream-us.com|support@blustream.co.uk
ACM500
Quick Reference Guide
OurUHDSDVoEMulticastdistributionplatformallows distributionof thehighest
quality,uncompromised4KwithzerolatencyAudio/Videoover copperor optical
fibre10GbE networks.
TheACM500ControlModulefeaturesadvancedthirdpartycontrolof theSDVoE
10GbEMulticastsystemusingTCP/IP,RS-232 andIR.TheACM500includesa web
interfacemoduleforcontroland configurationoftheMulticastsystemandfeatures
‘dragand drop’sourceselectionwithvideo previewand independentroutingof IR,
RS-232,USB/KVM,AudioandVideo.Pre-builtBlustreamproductdrivers simplify
Multicastproductinstallationandnegatetheneedfor anunderstandingofcomplex
networkinfrastructures.
Introduction
FEATURES:
• Webinterface moduleforconfigurationandcontroloftheBlustreamSDVoE10GbEMulticastsystem
• Intuitive‘drag&drop’sourceselectionwithvideopreviewfeatureforactivemonitoringof systemstatus
• Advancedsignalmanagementforindependentroutingof IR,RS-232,CEC,USB/KVM,audio andvideo
• Autosystemconfiguration
• 2xRJ45LANconnectionstobridgeexistingnetwork toMulticast video distributionnetwork,resultingin:
-Bettersystemperformanceas network traicisseparated
-Noadvancednetwork setuprequired
-Independent IPaddressperLAN connection
-Allows simplified TCP/ IPcontrolofMulticastsystem
• DualRS-232 portsforcontroloftheMulticastsystemorpass-throughofcontroltoremotethirdpartydevices
• 5V /12VIRintegrationforcontrolofMulticastsystem
• PoE(Power overEthernet)topowerBlustreamproduct fromPoEswitch
• Local12Vpowersupply(optional) shouldEthernetswitchnotsupportPoE
• SupportforIOSandAndroidApp control
• 3rdpartydriversavailableforallmajorcontrolbrands

ACM500 QUICK REFERENCE GUIDE
02 www.blustream.com.au|www.blustream-us.com|www.blustream.co.uk
RearPanelDescription
1PowerConnection(optional) -use12V1ADCpowersupplywherePoEswitchdoes notprovidepowerfromVideo
LAN switch
2Video LAN(PoE)-connect tothenetworkswitchthattheBlustreamMulticastcomponentsareconnectedto
3ControlLANPort -connecttoexistingnetwork thatathirdparty controlsystemresides on. The ControlLAN portis
used forTelnet/IPcontrolof the Multicast system. NotPoE.
4RS-2321ControlPort –connect toa thirdpartycontrol deviceforcontroloftheMulticast systemusingRS-232.
5RS-232 2 ControlPort–connecttoathirdpartycontroldevicefor controloftheMulticast systemusingRS-232.
6GPIOConnections- 6-pinPhoenixconnect forinput /outputtriggers(reservedforfutureuse)
7GPIOVoltageLevelSwitch (reservedforfutureuse)
8IRCtrl (IRInput)– 3.5mmstereojack.Connect tothirdpartycontrol systemifusingIRasthechosenmethodof
controllingtheMulticast system.Whenusingthe included3.5mmstereotomonocable,ensurethe cabledirection
iscorrect.
9IRVoltageSelection- adjustIR voltagelevelbetween5Vor12Vinputfor IR CTRL connection.
SignIn
BeforeloggingintotheACM500,ensurethatthecontroldevice(i.e.laptop /tablet)is connected tothesame network
astheACM500’sControlport.Tologin,open awebbrowser(i.e.Firefox,InternetExplorer,Safarietc.)and navigate to
thedefault (static)IPaddressoftheACM500whichis:
192.168.0.225
TheACM500canalsobe foundatthebeacon addressat:
http://acm500.local
TheIPaddressand/orbeacon addresscan beamendedfrom theweb-GUIofthe ACM500.Pleaserefertothefull
instruction manualwhichcanbedownloadedfromtheBlustreamwebsite.
TheSignIn pageispresentedonconnection totheACM500.Thedefault admincredentialsareasfollows:
Username:blustream Password:1 2 3 4
Thefirst timetheACM500issignedinto, you willbepromptedtoseta new Adminpassword. Pleaseinserta new
password,confirm your new password,andensurethis iskeptsafe.TheACM500will requirethe unittobesignedinto
againusingthenewAdminpassword.
1 2 3 4 5 6 7 8 9

ACM500 QUICK REFERENCE GUIDE
03Contact: support@blustream.com.au|support@blustream-us.com|support@blustream.co.uk
Schematic
Example Schematic
ACM500
Reserved for future update
Control Processor
Optional 12V PSU
where no PoE is available
10 GbE Multicast UHD
Network Switch
IP500UHD-TZ
10GbE Managed Network Switch
Customer Home / Business
Network Switch
Network Switch
RS-232
LAN
IR
SFP+ Fibre Connection
10 GBase - T LAN
Impotant Note:
TheBlustream IP500UHDMulticast system distributesHDMIvideoover 10GbEManagednetworkhardware. Itisadvisedthat
BlustreamMulticastproducts areconnectedonanindependentnetworkswitchtopreventunnecessaryinterference, orreduction
insignalperformanceduetoothernetworkproductsbandwidthrequirements.Pleasereadandunderstandtheinstructions in
thisandthe manualavailableonline,andensurethatthenetworkswitchisconfiguredcorrectlypriortoconnectinganyBlustream
Multicast products.Failuretodo sowillresultinproblemswith configurationofthe system,and videoperformance.

ACM500 QUICK REFERENCE GUIDE
04 www.blustream.com.au|www.blustream-us.com|www.blustream.co.uk
PackageContents
Specifications
• 1xACM500
• 1xIRControlCable-3.5mmto3.5mmCable
• 1xMountingkit
• 4xRubber feet
• 1xQuickReferenceGuide
NOTE: Specifications are subject to change without notice. Weights and dimensions are approximate.
ACM500
• Ethernet port: 2x LANRJ45connector(1xPoEsupport)
• RS-232 serial port: 2x 3-pinPhoenixconnector
• I/O port: 1x 6-pinPhoenixconnector(reservedforfutureuse)
• IR input port: 1 x3.5mmstereojack
• Product upgrade: 1x MicroUSB
• Dimensions (W x D x H): 190.4mmx93mmx25mm
• Shipping weight: 0.6kg
• Operating temperature: 32°F to104°F(0°C to40°C)
• Storage temperature: -4°F to140°F(-20°Cto60°C)
• Power supply: PoEor12V 1ADC(soldseparately) -wherePoEnotdeliveredbyLANswitch
RevA1_QRG_ACM500_040122
FCC NOTICE
Thisequipmenthasbeentestedandfoundtocomplywith
thelimitsforaClassBdigitaldevice,pursuanttopart15ofthe
FCCRules.Theselimitsaredesignedtoprovidereasonable
protectionagainstharmfulinterferenceinaresidential
installation.Thisequipmentgenerates,uses,andcanradiate
radiofrequencyenergyand,ifnotinstalledandusedin
accordancewiththeinstructions,maycauseharmfulinterference
toradiocommunications.However,thereisnoguaranteethat
interferencewillnotoccurinaparticularinstallation.Ifthis
equipmentdoescauseharmfulinterferencetoradioortelevision
reception,whichcanbedeterminedbyturningtheequipmento
andon,theuserisencouragedtotrytocorrecttheinterference
byoneormoreofthefollowingmeasures:
•Reorientorrelocatethereceivingantenna.
•Increasetheseparationbetweentheequipmentandreceiver.
•Connecttheequipmentintoanoutletonacircuitdierentfrom
thattowhichthereceiverisconnected.
•Consultthedealeroranexperiencedradio/TVtechnicianfor
help.
CAUTION -changesormodificationsnotexpresslyapproved
bythepartyresponsibleforcompliancecouldvoidtheuser’s
authoritytooperatetheequipment.
CANADA, INDUSTRY CANADA (IC) NOTICES
ThisClassBdigitalapparatuscomplieswithCanadianICES-003.
Operationissubjecttothefollowingtwoconditions:(1)this
devicemaynotcauseinterference,and(2)thisdevicemustaccept
anyinterference,includinginterferencethatmaycauseundesired
operationofthedevice.
CORRECT DISPOSAL OF THIS PRODUCT
Thismarkingindicatesthatthisproductshouldnotbedisposed
withotherhouseholdwastes.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,
recycleitresponsiblytopromotethesustainablereuseofmaterial
resources.Toreturnyouruseddevice,pleaseusethereturnand
collectionsystemsorcontacttheretailerwheretheproductwas
purchased.Theycantakethisproductforenvironmentallysafe
recycling.
Certifications
Other manuals for ACM500
1
Other Blu Stream Control Unit manuals
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual