BI COMMUNICATIONS Lan Caster ProST User manual

ENGLISH
User Manual
BI Communications
Innovation through Technology
ProProSTST
Structured Cable Tester
& TDR Fault Locator
Structured Cable Tester
& TDR Fault Locator
ProPro
BI Communications
Innovation through Technology
18:24
LanCaster
Pro ST
03:11:05
TIA568 STP Vp=79%


SECTION 1 INTRODUCTION
SECTION 2 PRODUCT FEATURES
SECTION 3 SPECIFICATIONS
SECTION 4 FIRST OPERATIONS
SECTION 5 USING THE Lancaster Pro ST
1.1 Receiving Shipment ...................................................6
2.1 Description ............................................................7
2.2 Lancaster Pro ST Features ........................................7
4.1 Preparing Lancaster Pro ST For Use ........................11
4.2 Menu Architecture ......................................................12
4.3 Selecting Language ...................................................13
4.4 Set Unit Of Measure ..................................................13
4.5 Set Time And Date .....................................................13
4.6 Select Wiring Type .....................................................13
4.7 Set Volocity Of Propogation .......................................13
4.8 Adjusting Contrast .....................................................14
4.9 Setting Auto Shutdown ..............................................14
4.10 Address Settings ........................................................14
4.11 Volocity Of Propogation .............................................15
5.1 T.N.V. (Telecom Network Voltage) .............................16
5.2 Services Detection .....................................................17
5.3 General Operation .....................................................17
5.4 Test Pass Screen .......................................................19
5.5 Test Failed Screen .....................................................20
5.5.1 Open And Short Fault ................................................20
5.5.2 Reversed And Split Pair Fault ....................................21
5.5.3 Multipul Faults ............................................................22
5.5.4 Missing Remote .........................................................22
5.6 Cable Length Measurement ......................................23
5.7 Tone Generator ..........................................................24
5.8 Backlight ............................................................24
TABLE OF CONTENTS

SECTION 6 DOWNLOADING TO P.C.
SECTION 7 WIRING PROTOCOLS
SECTION 8 MAINTENANCE
6.1 Linking Lancaster Pro ST To PC..................................25
6.2 Selective Download ...................................................25
6.3 Full Download ............................................................25
6.4 Erasing Memory .........................................................26
TABLE OF CONTENTS

War ning
●This instrument meets the safety requirements of IEC61010-1:
1995.
●The Lancaster Pro ST is designed for use on de-energized
circuits only.
●Connection to line voltages will damage the instrument and
could be hazardous to the operator.
●This instrument is protected against connection to telecom
network voltages according to EN61326-1.
●Safety is the responsibility of the operator.
International Electrical Symbols
This symbol signifies that the instrument is protected by double or
reinforced insulation. Use only specified replacement parts when
servicing the instrument.
This symbol on the instrument indicates a WARNING and that
the operator must refer to the user manual for instructions before
operating the instrument. In this manual, the symbol preceding
instructions indicates that if the instructions are not followed, bodily
injury, installation/sample and product damage may result.
Risk of electric shock. The voltage at the parts marked with this
symbol may be dangerous.
SECTION 1-INTRODUCTION
5

1.1 Receiving Your Shipment
Upon receiving your shipment, make sure that the contents are consistent
with the packing list. Notify your distributor of any missing items. If the
equipment appears to be damaged, file a claim immediately with the carrier
and notify your distributor at once, giving a detailed description of any
damage.
6

2.1 Description
Features:
The Lancaster Pro ST, is a hand held structured cabling tester and trouble
shooter, designed for use on screened and unscreened cables. Fitted with
RJ45 connectors and wired to either TIA568 A/B, U.S.O.C or I.S.D.N
standards. It will store up to 1,000 test results for downloading to P.C to
produce an installation test report, showing time and date of test, wiring
standard, installed cable length, pass/fail result and location of site tested.
All test results for display textually and graphically along with cable length,
wiring standard, V.P, an outlet address and smart remote ID number,
audible pass/fail tone is emitted by the main unit with a red/green pass/fail
LED on the remote unit.
When plugged into an active port it will emit an audible tone if telephone
voltages are present on any of the pins and will identify 10 base T. Token
Ring and 100 Mbit connections and inhibit testing, in the presence of live
circuits an inbuilt tone generator can be selected for cable tracing.
!
!
!
!
!
!
!
!
!
Stores up to 1,000 test results
Complete with software for download to PC and generating test
reports
Rugged case design rated to IP54
Scratch resistant front screen
128x64 Electro luminescent backlit display
Detects open circuits, shorts, crossed wires, crossed pairs, reversed
pairs, split pairs and screen faults
Measures length of all 4 pairs and indicates distance to fault
Tone generator for cable tracing
Supports up to 16 uniquely numbered smart remote units
SECTION 2-PRODUCT FEATURES
7

2.2 LanCaster Features
1 RJ45 Input connector
2 Graphical L.C.D
3 Service button
4 Length test button
5 Wire map test button
6 Address settings
7 Back light button
8 Power on/off button
9 Remote ID button
10 Pass/fail test BI colour L.E.D
Buttons 3 to 6 have the following functions, when menu is selected
5-To scroll cursor arrow
3-To increment setting
4-To decrement setting
6-Return to menu
8
Structured Cable Tester
& TDR Fault Locator
Structured Cable Tester
& TDR Fault Locator
ProPro
BI Communications
Innovation through Technology
18:24
LanCaster
Pro ST
03:11:05
TIA568 STP Vp=79%
With nd Discrimination Technology
EDT™
E
Remote UnitRemote Unit
1
BI Communications
Innovation through Technology
1
2
3
5
7
4
6
8
1
9
10

Range: 500 ft (150m)
Accuracy: ±5%
Cable Types: UTP, STP, FTP & SSTP
Faults Indicated: Short Circuit Pair
Open Circuit Wire
Short Between Pairs
Split / Cross Pairs
Pair Reversals
Shield Continuity
Fault Location: Near End, Remote End, or distance
if midway
Wiring Schemes: TIA 568A/B, USOC & ISDN
Service Indication: Telephone, 10BaseT, 100Mbit+,
Token Ring
Voltage Warning: Warns of TNV (Telecom Network
Voltage) presence
Test Inhibit: Inhibits Testing in the presence of
live voltages
Tone Generator:
Tone generator (oscillating) 810Hz - 1110Hz
Battery indicator: “Gas Gauge”Bargraph
Main Unit Display: 128 x 64 pixel Graphical LCD
Fault Display: All fault and setting info displayed
textually and graphically
Display Backlight: Electroluminescent
Remote Display: Green/Red LED
Languages: English (USA and UK), German,
French, Spanish, Portuguese, Italian
SECTION 3-SPECIFICATIONS
Power Supply: 4 x 1.5V AA alkaline batteries
Auto Power Off: Selectable, disabled 1, 2, 3 minutes
or disabled
9

Battery Life: Standby mode >4000hrs
Continuous testing >7.5hrs
Storage Temperature: (-4 to 158°F)-20 to 70°C
5 to 95% RH non-condensing
Operating Temperature: 32 to 112°F0 to 40°C ( )
5 to 95% RH non-condensing
Main Unit Weight: 12 oz350g ( )
Main Unit Dimensions: 6.5 x 3.5 x 1.5”)165 x 90 x 37mm (
Remote Weight: (1.5 oz)40g
Remote Dimensions: 2.5 x 2.0 x 1.0”)65 x 52 x 25mm (
Safety: IEC61010-1
EMC: EN61326-1
CE: Compliant with current EU directives
ESD: EN61000-4-2
EM: EN61000-4-3
Burst: EN61000-4-4
Conducted RF: EN61000-4-6
10
Table of contents
Other BI COMMUNICATIONS Test Equipment manuals