PRODUCT DESCRIPTION:
This signal converter module is used with
10-180 ohm, or 240-33 ohm tank senders to
produce a 0-5V output.
BEP equipment that uses a 0-5 volt signal
input includes the DCSM DC/Systems
Monitor, CZone Digital Switching/Monitoring,
and the (obsolete) 600-TLM tank monitor.
SPECIFICATIONS:
Supply voltage: 10-32 volts
Switchable jumper (link) for 240-33, or
10-180 ohm inputs (Supplied with jumper set
to suit 240-33 ohm senders)
Output voltage: 0-5 volts
Important Note:
Tank monitoring must be calibrated to ensure
that monitor matches tank conditions!
The 240-33 ohm senders may indicate some
tank contents when in fact the tank is empty
600-TLM-SIF TANK SENDER
MODULE INTERFACE
OWNERS INSTRUCTION MANUAL