Bender NGRM500 User manual

NGRM500 (HRG)
NGRM550 (LRG)
Neutral Grounding Resistor Monitor
NGRM5xx_D00373_06_M_XXEN/02.2022 Manual EN

Bender GmbH & Co. KG
Londorfer Str. 65 • 35305 Grünberg • Germany
PO Box 1161 • 35301 Grünberg • Germany
Tel.: +49 6401 807-0 • Fax: +49 6401 807-259
E-Mail: info@bender.de • www.bender.de
©Bender GmbH & Co. KG
All rights reserved.
Reprinting only with permission of the publisher.
Subject to change!
Photos: Bender archive

3
Table of Contents
NGRM5xx_D00373_06_M_XXEN/02.2022
1. Important information ........................................................................... 7
1.1 How to use this manual ................................................................................... 7
1.2 Technical support: service and support .................................................... 8
1.2.1 First level support .......................................................................................... 8
1.2.2 Repair service .................................................................................................. 8
1.2.3 Field service ..................................................................................................... 8
1.3 Training courses ................................................................................................. 9
1.4 Delivery conditions ........................................................................................... 9
1.5 Inspection, transport and storage ............................................................... 9
1.6 Warranty and liability ....................................................................................... 9
1.7 Disposal ............................................................................................................... 10
2. Safety instructions ............................................................................... 11
2.1 General safety instructions .......................................................................... 11
2.2 Work activities on electrical installations ................................................ 11
2.3 Intended use ..................................................................................................... 11
2.4 Glossary ............................................................................................................... 12
3. Function ................................................................................................. 13
3.1 Device features ................................................................................................. 13
3.2 Functional description ................................................................................... 14
3.3 NGRM500: Recommended minimum value RNGR
(tripping level 50 %) ....................................................................................... 15
3.3.1 Recommended RNGR for system voltage Usys ≤ 4300 V
(HRG system) ................................................................................................ 15
3.3.2 Recommended RNGR for system voltage Usys > 4300 V
(HRG system) ................................................................................................ 16

Table of Contents
4NGRM5xx_D00373_06_M_XXEN/02.2022
4. Mounting ............................................................................................... 17
4.1 Dimension diagram NGRM5… .................................................................. 17
4.2 Enclosure view .................................................................................................. 18
4.3 Screw mounting ............................................................................................... 19
4.4 DIN rail mounting ............................................................................................ 20
5. Connection ............................................................................................. 21
5.1 Connection requirements ............................................................................ 21
5.2 Connection descriptions of CD-series coupling device ..................... 22
5.3 Recommended connecting cable coupling device CD… ................ 22
5.4 Star connection ................................................................................................ 23
5.4.1 Connection .................................................................................................... 23
5.4.2 Connection with pulser ............................................................................. 24
5.4.3 Artificial neutral (delta connection) ...................................................... 25
5.5 CT connection ................................................................................................... 26
5.6 Connection of relays
(ground-fault, NGR-fault and trip relay) .................................................. 27
5.7 Connection to the X1 interface .................................................................. 27
5.7.1 X1: Input I1…3 .............................................................................................. 28
5.7.2 X1: Output Q1…2 ........................................................................................ 29
5.7.3 X1: Analogue output .................................................................................. 30
6. User interface ......................................................................................... 31
6.1 Operating elements ........................................................................................ 31
6.2 Standard display .............................................................................................. 33
6.3 Fault indication (active) ................................................................................. 33
6.4 Fault indication (inactive) ............................................................................. 34
6.5 Acknowledging a fault message ................................................................ 34
6.6 History memory ................................................................................................ 35

Table of Contents
5
NGRM5xx_D00373_06_M_XXEN/02.2022
7. Menu ....................................................................................................... 36
7.1 Overview ............................................................................................................. 36
7.2 Navigating through the menu ................................................................... 37
7.3 Changing settings ........................................................................................... 37
7.4 Data measured values (menu 1) ................................................................ 38
7.5 Harmonics (menu 2) ....................................................................................... 39
7.6 History (menu 3) .............................................................................................. 39
7.7 Pulser (menu 4) ................................................................................................ 40
7.8 Display (menu 5) .............................................................................................. 40
7.9 HRG/LRG settings (menu 6) ......................................................................... 41
7.9.1 HRG system (menu 6.1) ............................................................................. 41
7.9.2 CT (menu 6.2) ................................................................................................ 41
7.9.3 NGR (menu 6.3) ............................................................................................ 42
7.9.4 Response values (menu 6.4) .................................................................... 42
7.9.5 System settings (menu 6.5) ...................................................................... 46
7.9.6 Field calibration (menu 6.6) ..................................................................... 47
7.10 Device settings (menu 7) .............................................................................. 48
7.11 Commissioning (menu 8) ............................................................................. 52
7.12 Info (menu 9) ..................................................................................................... 53
7.13 Alarm (menu 10) .............................................................................................. 53
8. Initial commissioning .......................................................................... 54
8.1 Response values ............................................................................................... 54
8.2 Output relays operating modes ................................................................. 55
8.2.1 Field calibration ........................................................................................... 55
8.2.2 Trip times ........................................................................................................ 56
8.3 RMS trip signal, fundamental, harmonics ............................................... 58
8.4 Initial measurement ....................................................................................... 58

Table of Contents
6NGRM5xx_D00373_06_M_XXEN/02.2022
9. Analogue and digital I/O configuration ........................................... 60
9.1 Analogue output (menu 6.6.4) ................................................................... 60
9.2 Digital outputs (Q1, Q2) ................................................................................ 60
9.2.1 Use of Q1: Device health ........................................................................... 61
9.2.2 Use of Q2: Pulser ......................................................................................... 61
9.3 Digital inputs ..................................................................................................... 61
10. Test cycle .............................................................................................. 62
11. Factory settings ................................................................................... 63
12. Error codes ........................................................................................... 65
13. Technical data ..................................................................................... 66
13.1 Tabular data ....................................................................................................... 66
13.2 Standards, approvals, certifications .......................................................... 71
13.3 Ordering details ............................................................................................... 71
13.3.1 NGR monitor .................................................................................................. 71
13.3.2 Accessories ..................................................................................................... 71
13.4 Document revision history ........................................................................... 72

Important information
7
NGRM5xx_D00373_06_M_XXEN/02.2022
1. Important information
1.1 How to use this manual
Always keep this manual within easy reach for future reference. To make it easier
for you to understand and revisit certain sections in this manual, we have used symbols
to identify important instructions and information. The meaning of these symbols is ex-
plained below:
This manual is intended for qualified personnel working in electrical
engineering and electronics!
This signal word indicates that there is a high risk of danger that will
result in death or serious injury if not avoided.
This signal word indicates a medium risk of danger that can lead to
death or serious injury, if not avoided.
This signal word indicates a low-level risk that can result in minor or
moderate injury or damage to property if not avoided.
This symbol denotes information intended to assist the user in making
optimum use of the product.
DANGER
WARNING
CAUTION

Important information
8NGRM5xx_D00373_06_M_XXEN/02.2022
1.2 Technical support: service and support
For commissioning and troubleshooting Bender offers:
1.2.1 First level support
Technical support by phone or e-mail for all Bender products
Questions about specific customer applications
Commissioning
Troubleshooting
Telephone: +49 6401 807-760*
Fax: +49 6401 807-259
In Germany only: 0700BenderHelp (Tel. and Fax)
E-mail: [email protected]
1.2.2 Repair service
Repair, calibration, update and replacement service for Bender products
Repair, calibration, testing and analysis of Bender products
Hardware and software update for Bender devices
Delivery of replacement devices for faulty or incorrectly delivered Bender devices
Extended warranty for Bender devices with in-house repair service or replacement
devices at no extra cost
Telephone: +49 6401 807-780** (technical issues)
+49 6401 807-784**, -785** (commercial issues)
Fax: +49 6401 807-789
E-mail: [email protected]
Please send the devices for repair to the following address:
Bender GmbH, Repair-Service,
Londorfer Straße 65,
35305 Grünberg
1.2.3 Field service
On-site service for all Bender products
Commissioning, parameter setting, maintenance, troubleshooting for Bender prod-
ucts
Analysis of the electrical installation in the building (power quality test, EMC test, ther-
mography)
Practical training courses for customers

Important information
9
NGRM5xx_D00373_06_M_XXEN/02.2022
Telephone: +49 6401 807-752**, -762 **(technical issues)
+49 6401 807-753** (commercial issues)
Fax: +49 6401 807-759
E-mail: [email protected]
Internet: www.bender.de
*Available from 7.00 a.m. to 8.00 p.m. on 365 days of the year (CET/UTC+1)
**Mo-Thu 7.00 a.m. - 8.00 p.m., Fr 7.00 a.m. - 13.00 p.m
1.3 Training courses
Bender is happy to provide training regarding the use of test equipment.
The dates of training courses and workshops can be found on the Internet at www.bend-
er.de > Know-how > Seminars.
1.4 Delivery conditions
The conditions of sale and delivery set out by Bender apply.
For software products, the "Softwareklausel zur Überlassung von Standard- Software
als Teil von Lieferungen, Ergänzung und Änderung der Allgemeinen Lieferbedingun-
gen für Erzeugnisse und Leistungen der Elektroindustrie" (software clause in respect of
the licensing of standard software as part of deliveries, modifications and changes to
general delivery conditions for products and services in the electrical industry) set out
by the ZVEI (Zentralverband Elektrotechnik- und Elektronikindustrie e.V., (German Elec-
trical and Electronic Manufacturers' Association) also applies.
Conditions of sale and delivery can be obtained from Bender in printed or electronic for-
mat.
1.5 Inspection, transport and storage
Inspect the dispatch and equipment packaging for damage, and compare the contents
of the package with the delivery documents. In the event of damage in transit, please
contact Bender immediately.
The devices must only be stored in areas where it is protected from dust, humidity and
spray or dripping water, and in which the specified storage temperatures can be as-
sured.
1.6 Warranty and liability
Warranty and liability claims in the event of injury to persons or damage to property are
excluded if they can be attributed to one or more of the following causes:
Improper use of the device.
Incorrect mounting, commissioning, operation and maintenance of the device.

Important information
10 NGRM5xx_D00373_06_M_XXEN/02.2022
Failure to observe the instructions in this operating manual regarding transport, com-
missioning, operation and maintenance of the device.
Unauthorised changes to the device made by parties other than the manufacturer.
Non-observance of technical data.
Repairs carried out incorrectly and the use of replacement parts or accessories not
approved by the manufacturer.
Catastrophes caused by external influences and force majeure.
Mounting and installation with device combinations not recommended by the manu-
facturer.
This operating manual, especially the safety instructions, must be observed by all per-
sonnel working on the device. Furthermore, the rules and regulations that apply for ac-
cident prevention at the place of use must be observed.
1.7 Disposal
Abide by the national regulations and laws governing the disposal of this device. Ask
your supplier if you are not sure how to dispose of the old equipment.
The directive on waste electrical and electronic equipment (WEEE directive) and the di-
rective on the restriction of certain hazardous substances in electrical and electronic
equipment (RoHS directive) apply in the European Community. In Germany, these pol-
icies are implemented through the "Electrical and Electronic Equipment Act" (ElektroG).
According to this, the following applies:
Electric and electronic equipment are not to be included in household waste.
Batteries and accumulators are not to be included in household waste but must be
disposed of in accordance with the regulations.
Old electrical and electronic equipment from users other than private households
which was introduced to the market after 13th August 2005 must be taken back by
the manufacturer and disposed of properly.
For more information on the disposal of Bender devices, refer to our homepage at
www.bender.de -> Service & support.
Other manuals for NGRM500
5
This manual suits for next models
1
Table of contents
Other Bender Control System manuals