Beha-Amprobe AM-535-EUR User manual


AM-535-EUR
Digital Multimeter
User Manual
6/2015, 6005740 A
©2015 Amprobe Test Tools.
All rights reserved. Printed in China
English

Limited Warranty and Limitation of Liability
Your Amprobe product will be free from defects in material and workmanship for one
year from the date of purchase unless local laws require otherwise. This warranty does
not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation or handling. Resellers are not authorized
to extend any other warranty on the behalf of Amprobe. To obtain service during the
warranty period, return the product with proof of purchase to an authorized Amprobe
Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS
WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED
OR STATUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE
OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE
FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES,
ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the
exclusion or limitation of an implied warranty or of incidental or consequential damages, this
limitation of liability may not apply to you.
Repair
All Amprobe returned for warranty or non-warranty repair or for calibration should be
accompanied by the following: your name, company’s name, address, telephone number,
and proof of purchase. Additionally, please include a brief description of the problem or
the service requested and include the test leads with the meter. Non-warranty repair or
replacement charges should be remitted in the form of a check, a money order, credit card
with expiration date, or a purchase order made payable to Amprobe.
In-warranty Repairs and Replacement – All Countries
Please read the warranty statement and check your battery before requesting repair. During
the warranty period, any defective test tool can be returned to your Amprobe distributor
for an exchange for the same or like product. Please check the “Where to Buy” section on
www.Amprobe.com for a list of distributors near you. Additionally, in the United States and
Canada, in-warranty repair and replacement units can also be sent to an Amprobe Service
Center (see address below).
Non-warranty Repairs and Replacement – United States and Canada
Non-warranty repairs in the United States and Canada should be sent to an Amprobe Service
Center. Call Amprobe or inquire at your point of purchase for current repair and replacement
rates.
USA: Canada:
Amprobe Amprobe
Everett, WA 98203 Mississauga, ON L4Z 1X9
Tel: 877-AMPROBE (267-7623) Tel: 905-890-7600
Non-warranty Repairs and Replacement – Europe
European non-warranty units can be replaced by your Amprobe distributor for a nominal
charge. Please check the “Where to Buy” section on www.Beha-Amprobe.com for a list of
distributors near you.
Amprobe Europe*
Beha-Amprobe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
www.Beha-Amprobe.com
*(Correspondence only – no repair or replacement available from this address. European
customers please contact your distributor.)

AM-535-EUR Digital Multimeter
1Flash light
2LC Display
3Function Buttons
4Flash light Button
5Rotary Switch
6SELECT Button
7Input Terminal for voltage, diode, capacitance,
Resistance, continuity and temperature measurement
8COM (return) terminal for all measurements
9Input Terminal for AC/DC mA/uA measurement
10 Input Terminal for AC/DC A measurement up to 20A
1
2
7
8
3
4
5
9
10
6

Screen Display
1The Meter selects the range with best resolution
2Direct Current
3Negative reading
4Alternate Current
5Low battery indicator
6Data hold
7Diode test
8Continuity test
9Relative zero mode
10 Non-Contact Voltage
11 Measurement units for Resistance
12 Measurement units for Frequency
13 Measurement units for Voltage
14 Measurement units for Current
15 Measurement units for Capacitance
16 Auto Power Off
17 Maximum / minimum reading memory
18 Measurement unit for Temperature
19 Analog bar graph display
1
2
9
6 8 7
3
4
5
10 13 14 1517
18
12
11
19
16

1
AM-535-EUR Digital Multimeter
CONTENTS
SYMBOL.................................................................................................................2
SAFETY INFORMATION .........................................................................................2
UNPACKING AND INSPECTION .............................................................................3
FEATURES...............................................................................................................4
MAKING MEASUREMENT .....................................................................................5
Measuring AC and DC Voltage.........................................................................6
Measuring AC and DC Current.........................................................................7
Measuring Resistance .......................................................................................8
Measuring Continuity.......................................................................................9
Measuring Diode...............................................................................................9
Measuring Capacitance ....................................................................................10
Measuring Frequency .......................................................................................10
Measuring Temperature °C /°F .........................................................................11
Non-Contact Voltage Sensing ..........................................................................12
SPECIFICATION.......................................................................................................13
MAINTENANCE......................................................................................................16
BATTERY AND FUSE REPLACEMENT.....................................................................17

2
SYMBOLS
Caution ! Risk of electric shock.
Caution! Refer to the explanation in this Manual
Alternating Current (AC)
Direct Current (DC)
The equipment is protected by double insulation or reinforced
insulation
Earth (Ground)
Audible tone
Battery
Complies with European Directives
Conforms to relevant Australian standards
Canadian Standards Association (NRTL/C)
Do not dispose of this product as unsorted municipal waste.
Contact a qualified recycler.
SAFETY INFORMATION
The Meter complies with:
IEC/EN 61010-1 3rd Edition, UL61010-1 2nd Ed. and CAN/CSA C22.2 No.
61010.1-0.92 to Category III 600 Volts, Pollution degree 2
IEC/EN 61010-2-030
IEC/EN 61010-031 for test leads
EMC IEC/EN 61326-1
Measurement Category III (CAT III) is for measurements performed in the
building installation. Examples are measurements on distribution boards,
circuit- breakers, wiring, including cables, bus-bars, junction boxes, switches,
socket-outlets in the fixed installation, and equipment for industrial use
and some other equipment, for example, stationary motors with permanent
connection to the fixed installation.

3
Measurement Category II (CAT II) is for measurements performed on circuit
directly connected to low voltage installation. Examples are measurements on
household appliances, portable tools and similar equipments.
Warning: Read Before Using
• To avoid possible electrical shock or personal injury, follow these
instructions and use the Meter only as specified in this manual.
• Do not use the Meter or test leads if they appear damaged, or if the
Meter is not operating properly. If in doubt, have the Meter serviced.
• Always use the proper function and range for measurements.
• Before rotating the function range selection switch, disconnect test
probe from circuit under test.
• Verify the Meter’s operation by measuring on a known voltage source.
• Do not apply more than the rated voltage, as marked on the Meter,
between the test probe or between any test probe and earth ground.
• Use the Meter with caution for voltages above 30 Vac rms, 42 Vac peak,
or 60 Vdc. These voltages pose electrical shock hazards.
• Disconnect circuit power and discharge all high-voltage capacitors before
testing resistance.
• Do not use the Meter around explosive gas or vapor.
• When using the test leads, keep your fingers behind the finger guards.
• Remove test leads from the Meter before opening the Meter case or
battery door.
UNPACKING AND INSPECTION
Your shipping carton should include:
1 AM-535-EUR
1 Pair of test leads
1 Temperature probe
1 Velcro strap
1 9V (6F22) battery (installed)
1 User manual
1 Carrying case
If any of the items are damaged or missing, return the complete package to
the place of purchase for an exchange.

4
FEATURES
AM-535-EUR is the fully-featured multimeter of choice for the professional
electrical contractor. Measure and verify presence of voltage in order to
connect equipment or to perform repairs, run new wiring, check continuity
of electrical connections, identify blown fuses, troubleshoot motors or check
transformers. The AM-535-EUR features Truerms sensing to accurately measure
voltage on systems affected by harmonics, a built in flashlight to detect wire
colors in the dark, a “third hand” probe holder and non-contact voltage
detection. Safety rated to CAT III 600V.
• Measurements: Voltage up to 600VAC and 600VDC, AC/DC current,
Resistance, Frequency, Capacitance, Temperature.
• Frequency, Capacitance, Duty Cycle for troubleshooting applications
• Special Functions:
- Non-contact Voltage Detection
- Audible continuity
- Diode Test
• Backlight LC Display with analog bar graph
• Events:
- Data hold
- MAX / MIN Memory
- Relative zero mode
• Built in work light (flashlight)
• Built in test leads storage and “third hand holder”
• Auto and Manual ranging
• Auto power off
• Low battery warning
• Velcro strap to hang a meter
• Safety: CAT III 600V
MAKING MEASUREMENT
1. Use the proper function and range for measurements.
2. To avoid possible electrical shock, personal injury or damages to the
Meter, disconnect circuit power and discharge all high-voltage capacitors
before testing resistance and diode.
This manual suits for next models
1
Table of contents
Languages:
Other Beha-Amprobe Multimeter manuals
Popular Multimeter manuals by other brands

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 operating instructions

PeakTech
PeakTech 4000 Procedure of calibration

YOKOGAWA
YOKOGAWA 90050B user manual

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 operating instructions

Fluke
Fluke 8846A Programmer's manual

Tempo Communications
Tempo Communications MM200 instruction manual