Beckhoff CU8803-000 Series User manual

Manual | EN
CU8803-000x
Transmitter box for CP-Link 4
2023-08-21 | Version: 2.0


Table of contents
CU8803-000x 3Version: 2.0
Table of contents
1 Notes on the documentation....................................................................................................................5
2 For your safety ..........................................................................................................................................6
2.1 Signal words......................................................................................................................................6
2.2 Intended use .....................................................................................................................................6
2.3 Fundamental safety instructions .......................................................................................................7
2.3.1 Special requirements (ATEX)............................................................................................. 7
2.3.2 Special requirements (IECEx)............................................................................................ 8
2.4 Operator's obligation to exercise diligence........................................................................................8
3 Product overview ......................................................................................................................................9
3.1 Structure............................................................................................................................................9
3.1.1 USB input .........................................................................................................................10
3.1.2 DVI input .......................................................................................................................... 10
3.1.3 CP-Link 4 output .............................................................................................................. 11
3.1.4 Power supply.................................................................................................................... 12
3.2 Name plate......................................................................................................................................13
4 Commissioning .......................................................................................................................................14
4.1 Transport and unpacking ................................................................................................................14
4.2 Control cabinet installation ..............................................................................................................15
4.3 Connect transmitter box ..................................................................................................................16
5 Decommissioning ...................................................................................................................................18
6 Maintenance ............................................................................................................................................20
7 Technical data .........................................................................................................................................21
8 Appendix..................................................................................................................................................22
8.1 Service and support ........................................................................................................................22
8.2 Approvals ........................................................................................................................................23

Table of contents
CU8803-000x4 Version: 2.0

Notes on the documentation
CU8803-000x 5Version: 2.0
1 Notes on the documentation
This description is only intended for the use of trained specialists in control and automation engineering who
are familiar with the applicable national standards.
The following instructions and explanations must be followed during installation and commissioning of the
components. The responsible staff must ensure that the application or use of the products described satisfy
all the requirements for safety, including all the relevant laws, regulations, guidelines and standards.
Disclaimer
The documentation has been prepared with care. The products described are, however, constantly under
development. For that reason the documentation is not in every case checked for consistency with
performance data, standards or other characteristics. In the event that it contains technical or editorial errors,
we retain the right to make alterations at any time and without warning. No claims for the modification of
products that have already been supplied may be made on the basis of the data, diagrams, and descriptions
in this documentation. All illustrations shown are only examples. The configurations depicted may deviate
from the standard.
Trademarks
Beckhoff®, TwinCAT®, TwinCAT/BSD®, TC/BSD ®, EtherCAT®, EtherCAT G®, EtherCAT G10®, EtherCAT P®,
Safety over EtherCAT®, TwinSAFE®, XFC®, XTS® and XPlanar® are registered and licensed trademarks of
Beckhoff Automation GmbH.
Other designations used in this publication may be trademarks whose use by third parties for their own
purposes could violate the rights of the owners.
Patents
The EtherCAT Technology is covered, including but not limited to the following patent applications and
patents: EP1590927, EP1789857, EP1456722, EP2137893, DE102015105702 and similar applications and
registrations in several other countries.
Copyright
© Beckhoff Automation GmbH & Co. KG. Publication of this document on websites other than ours is
prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the
grant of a patent, utility model or design.
Delivery state
All the components are supplied in particular hardware and software configurations appropriate for the
application. Changes to the hardware or software configuration are permitted, provided they are within the
specified limits for power consumption and power loss (please refer to the respective data sheet).
Currentness
Please check whether you are using the current and valid version of this document. The current version is
always available for download from the Beckhoff website. In case of doubt, contact Technical Support.
Delivery conditions
In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co. KG apply.

For your safety
CU8803-000x6 Version: 2.0
2 For your safety
The Safety chapter first explains the safety symbols used in the documentation and their meanings. They
contain fundamental safety instructions that are essential for the avoidance of personal injuries and damage
to property.
Exclusion of liability
Beckhoff shall not be liable in the event of non-compliance with this documentation and thus the use of the
devices outside the documented operating conditions.
2.1 Signal words
The signal words used in the documentation are classified below.
Warning of personal injuries
DANGER
Hazard with high risk of death or serious injury.
WARNING
Hazard with medium risk of death or serious injury.
CAUTION
There is a low-risk hazard that can result in minor injury.
Warning of property and environmental damage
NOTICE
There is a possibility of damage to the environment, equipment or data.
2.2 Intended use
The CP-Link4 transmitter box CU8803-000x is designed for DIN rail mounting in control cabinets of machine
and system engineering. It is used to operate a Control Panel CP29xx-0010, CP39xx-0010 or
CPX39xx-0010 at a distance of up to 100m from the industrial PC. The transmitter box can be used in
hazardous areas and is ATEX and IECEx certified.
The transmitter box is designed for a working environment that meets the IP20 protection rating. This
involves finger protection and protection against solid foreign objects up to 12.5mm. There is no protection
against water. Operation of the devices in wet and dusty environments is not permitted.
The specified limits for technical data must be adhered to.
The transmitter box can be used within the documented operating conditions.
Improper use
Do not use the transmitter box outside the documented operating conditions.

For your safety
CU8803-000x 7Version: 2.0
2.3 Fundamental safety instructions
The following safety instructions must be observed when handling the transmitter box.
Application conditions
• Do not use the transmitter box under extreme environmental conditions.
• Only use the transmitter box in hazardous areas if it is explicitly designed for this purpose.
• Never plug or unplug connectors during thunderstorms. There is a risk of electric shock.
• Provide protective grounding for the transmitter box.
Damage to property and impairment of functions
• Ensure that only trained specialists with a control and automation engineering background, operate the
PC to which the transmitter box is connected. Use by unauthorized persons can lead to damage to
property.
• Fuse the power supply line with max. 16A. The fuse serves to protect the supply line in the event of a
short circuit.
• In case of fire, extinguish the transmitter box with powder or nitrogen.
2.3.1 Special requirements (ATEX)
WARNING
Risk of explosion
Gases can be ignited in hazardous areas. Read and follow the safety instructions to avoid deflagration or
explosion.
The device must be installed in a suitable housing with IP54 protection rating according to EN 60079-15,
taking into account the environmental conditions in which the device will be used.
Precautions are to be taken to prevent the nominal voltage from being exceeded by transient disturbances in
excess of 119V.
Observe the permissible ambient temperature range of 0-55°C for the use of CU8803 in hazardous areas.
Secure the USB connector to the bracket with cable ties.
The device may only be used in an area with a maximum degree of pollution of 2 according to IEC 60664-7.

For your safety
CU8803-000x8 Version: 2.0
2.3.2 Special requirements (IECEx)
WARNING
Risk of explosion
Gases can be ignited in hazardous areas. Read and follow the safety instructions to avoid deflagration or
explosion.
The device must be installed in a suitable housing with IP54 protection rating according to EN 60079-15,
taking into account the environmental conditions in which the device will be used.
Precautions are to be taken to prevent the nominal voltage from being exceeded by transient disturbances in
excess of 119V.
Observe the permissible ambient temperature range of 0-55°C for the use of CU8803 in hazardous areas.
Secure the USB connector to the bracket with cable ties.
The device may only be used in an area with a maximum degree of pollution of 2 according to IEC 60664-7.
2.4 Operator's obligation to exercise diligence
The operator must ensure that
• the products are only used as intended (see chapter 2.2 Intended use [}6]).
• the products are only operated in sound condition and in working order.
• only sufficiently qualified and authorized personnel operate the PC to which the transmitter box is
connected.
• the personnel is instructed regularly about relevant occupational safety and environmental protection
aspects, and is familiar with the operating instructions and in particular the safety instructions contained
herein.
• the operating instructions are in good condition and complete, and always available for reference at the
location where the products are used.

Product overview
CU8803-000x 9Version: 2.0
3 Product overview
The CU8803-000x CP-Link4 transmitter box enables the control panel to be located up to 100m away from
the industrial PC. The transmitter box is located at a maximum distance of 1m from the industrial PC and
must be supplied with 24VDC. It transmits DVI, USB and the power supply to the control panel via a Cat.6A
cable (The One Cable Display Link).
The CU8803-0000 transmitter box is designed for connecting the Control Panels CP29xx-0010,
CP39xx-0010 and CPX39xx-0010 to a PC with a DVI port.
The CU8803-0001 transmitter box is designed for connecting the Control Panels CP29xx-0010 and
CP39xx-0010 to a C60xx PC or an ATX PC with DisplayPort.
3.1 Structure
The figure shows an example of a CU8803-0000 transmitter box.
1
4
6
7
2
5
3
Fig.1: Structure
Table1: Legend - CU8803 structure
No. Component Description
1 Power supply (X40) Power supply connection
2 FCC approval text FCC approvals for the United States of America and
Canada
3 Vendor Beckhoff Automation GmbH & Co. KG
4 Model Ending -0000: Device with DVI cable
Extension -0001: Device with DisplayPort cable
5 USB input (X10) Connection to the industrial PC
6 DVI input (X20) Connection to the industrial PC
7 CP-Link 4 output (X30) Transmission of DVI, USB and power supply to the
control panel

Product overview
CU8803-000x10 Version: 2.0
3.1.1 USB input
The transmitter box has a USB 2.0 input (X10) with socket type B. The transmitter box is connected to the
industrial PC via the USB input. The maximum cable length is 1 m.
2 1
4
3
X10
Fig.2: USB input pin numbering
Table2: USBinput pin assignment
Pin Assignment
1 Vbus
2 D -
3 D +
4 GND
3.1.2 DVI input
The transmitter box has a DVI input (X20). The transmitter box is connected to the industrial PC via the DVI
input. The maximum cable length is 1 m.
18
16
24
17
9
X20
Fig.3: DVI input pin numbering
Table3: DVI Extended interface pin assignment
Pin Assignment Pin Assignment Pin Assignment
1 TDMS Data 2 - 9 TDMS Data 1 - 17 TDMS Data 0 -
2 TDMS Data 2 + 10 TDMS Data 1 + 18 TDMS Data 0 +
3 TDMS Data 2/4 Shield 11 TDMS Data 1/3 Shield 19 TDMS Data 0/5 Shield
4 not used 12 not used 20 not used
5 not used 13 not used 21 not used
6 DDC Clock 14 + 5 V Power 22 TDMS Clock Shield
7 DDC Data 15 Ground (+ 5 V, Analog H/V
Sync)
23 TDMS Clock +
8 Analog Vertical Sync 16 Hot Plug Detect 24 TDMA Clock -
This manual suits for next models
2
Table of contents
Other Beckhoff Transmitter manuals
Popular Transmitter manuals by other brands

Dejero
Dejero EnGo 3x manual

Rosemount
Rosemount 4600 Reference manual

Speaka Professional
Speaka Professional 2342740 operating instructions

trubomat
trubomat GAB 1000 instruction manual

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 instructions

Rondish
Rondish UT-11 quick start guide