Autarco S2.LAN-BOX User manual

© Autarco Group B.V. IM.S2.LAN-GATEWAY-EN-V1.0
Installation manual
LAN Monitoring Gateway for Autarco inverters

2LAN Monitoring Gateway
Contact Information
Autarco Group B.V.
Schansoord 60
5469 DT Erp
The Netherlands
www.autarco.com
Other Information
This manual is an integral part of the unit. Please read the manual carefully before installation, operation or
maintenance. Keep this manual for future reference.
Product information is subject to change without notice. All trademarks are recognized as the property of their
respective owners.
If any technical problems occur, please contact us, with the following information in hand.
-Device Model
-Serial number of product
© Autarco Group B.V.
All rights reserved.

Installation manual
IM.S2.LAN-GATEWAY-EN-V1.0 3
Table of contents
1. Introduction 4
1.1 Read this first 4
1.2 Checklist 4
1.3 Interface and connection 5
1.4 Mounting gateway 5
2. Installing the LAN Monitoring Gateway 6
2.1 Connection with single inverter 6
2.2 Connection with multiple inverters 7
2.3 Confirm connection 8
3. Network setting 9
3.1 Connection via Wi-Fi 9
3.2 Connection via Ethernet 16
4. Registration 20
4.1 Check connection in MyAutarco 20
4.2 Monitoring setup 20
5. Debug 21
5.1 LED indication 21
5.2 Trouble Shooting 22
5.3 Reset 22

4LAN Monitoring Gateway
1. Introduction
1.1 Read this first
The main purpose of this user manual is to provide instructions and detailed procedures for installing, operating,
maintaining, and troubleshooting the Autarco LAN Monitoring Gateway which is used with the Autarco
inverters.
To reduce the risk of electrical shock, and to ensure the safe installation and operation of the LAN Monitoring
Gateway, the following safety symbol appears throughout this document to indicate dangerous conditions and
important safety instructions:
WARNING! Indicates safety instruction, which if not correctly followed, can result in injury or
property damages.
By connecting with single or multiple inverters through RS485/422 interface, the gateway can collect
information of PV-systems from inverters. The gateway connects to the router of the local area network, either
by WiFi or Ethernet cable, thereby transmitting data to the web server.
Users can check the runtime status of the device by checking the 4 LEDs on the panel, indicating power,
485/422, link and status respectively.
Please keep this user manual available at all times.
1.2 Checklist
After unpacking the box, please make sure all the items are contained as follows:
1 LAN Monitoring Gateway
(S2.LAN-BOX)
1 power adapter with
European or British plug
1 Quick Guide
2 expandable rubber hoses
2 screws
1 RS485 Monitoring cable

Installation manual
IM.S2.LAN-GATEWAY-EN-V1.0 5
1.3 Interface and connection
1.4 Mounting gateway
LAN Monitoring Gateway can be either wall-mounted or flatwise. It should at all times be installed indoors.
WARNING! When you screw/unscrew or adjust the antenna, please make sure that you only
use the metal part of the antenna. Do not hold the plastic part while adjusting otherwise the
antenna may be damaged.
LEDs
Antenna Port
RESET
Ethernet
SN serial number
RS485/422
Power adapter port

6LAN Monitoring Gateway
2. Installing the LAN Monitoring Gateway
2.1 Connection with single inverter
Connection to local router via WiFi
Connect inverter to gateway with monitoring cable and connect gateway to power supply with power adapter.
Connection to local router via ethernet cable
Connect inverter to gateway with monitoring cable, connect gateway to local router with network cable and
connect gateway to power supply with power adapter.
WARNING! Power supply of inverters must be cut off before connection. Make sure that all
connections are completed, then power the gateway and inverters, otherwise personal injury
or equipment damage may be caused.

Installation manual
IM.S2.LAN-GATEWAY-EN-V1.0 7
2.2 Connection with multiple inverters
1. Parallel connect multiple inverters with network cables.
2. Connect first inverter to gateway with network cable.
3. Set different address for each inverter. For example, when connecting three inverters, the address of
first inverter must be set as "01", the second must be set as "02", and the third must be set as "03" and
so on.
a. On the inverter, press ENTER and then UP/DOWN to navigate to SETTINGS
b. Select SET ADDRESS
c. Set address and press ENTER to save
d. For further details, please refer to inverter manual
4. Connect gateway to local router with ethernet cable if required, for connection by WiFi, go to step 5.
5. Connect gateway to power supply with power adapter.
Connection to local router via WiFi
Connection to local router via ethernet cable

8LAN Monitoring Gateway
2.3 Confirm connection
When all connections are finished and with the power on for about 1 minute, check the 4 LEDs. If POWER and
STATUS are permanently on, and LINK and 485/422 are permanently on or flashing, connections are successful.
If any problems, please refer to Chapter 5 ‘Debug’.

Installation manual
IM.S2.LAN-GATEWAY-EN-V1.0 9
3. Network setting
The LAN Monitoring Gateway can transfer information to the router via either Wi-Fi or Ethernet, users may
choose the appropriate method accordingly.
3.1 Connection via Wi-Fi
Step 1: Prepare a computer or device, e.g. table PC and smartphone that enables Wi-Fi.
Step 2: Obtain an IP address automatically
1. Open Wireless Network Connection Properties, double click Internet Protocol (TCP/IP)
2. Select Obtain an IP address automatically, and click OK.
WARNING! The setting hereinafter is operated with Window XP for reference only. If other
operating systems are used, please follow the corresponding procedures.

10 LAN Monitoring Gateway
Step 3: Set WiFi connection to the gateway
1. Open wireless network connection and click View Wireless Networks.
2. Select wireless network of the data logging module, no passwords required as default. The network
name consists of AP and the serial number of the product. Then click Connect.
Table of contents
Other Autarco Gateway manuals
Popular Gateway manuals by other brands

LST
LST M500RFE-AS Specification sheet

Kinnex
Kinnex Media Gateway quick start guide

2N Telekomunikace
2N Telekomunikace 2N StarGate user manual

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Original instructions

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE user guide

Telsey
Telsey CPVA 500 - SIP Technical manual