ArgoxScan AR-3000 User manual

0
NOTICE:
This equipment has been tested and it complies with
the limits for a Class a digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to
provide a reasonable protection against harmful
interference when the equipment is operated under a
commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in
a residential area is likely to cause harmful
interference in which case the user will be required to
correct the interference at his own expenses.
Note: All brands and trademarks shall belong to their
respective owner.
Note: Specification is subject to changes without
notice.
This device complies with Part 15 of the FCC Rules.
Operation shall be subject to the following two
conditions:
(1) This device may not cause harmful interface, and
(2) This device must accept any interface received,
including interface that may cause undesirable
operation.

1
Using the ArgoxScan AR-3000
The ArgoxScan can automatically scan barcode at a distance.
Simply aim and pull the trigger. Code scanning is performed
along the center of the light bar emitted from the reading
window. This bar must cover the entire code.
Recommended Steps
When the required settings have been configured, all settings
are stored in non- volatile memory of the scanner after
reading EXIT Label. Recommended steps are as follows.
1) Set the right host interface for your scanner.
(The scanner is in factory default shown as bold label)
2) Set interface to optimize protocol of the scanner with
your host in interface section.
3) Set system control of the scanner, such as specific
adjustments double confirm, indicator and scanning
mode which you prefer using in the system control
section.
4) Set code options of the scanner for your usage in the
code option section. You must make sure to enable the
symbology first, then Min./Max. code length, code ID
checksum and truncate digits are also converted.
5) Set string format of the scanner, such as preamble,
postamble Prefix, suffix, code ID and code name
transmission for your application in the string format
section.
Note: If it stil does not work properly. Please contact your
dealer for further information.

2
CONTENTS
Chapter 1 Introduction
Introduction
Default Setting ……………………………………….
4
ArgoxScanAR-3000 specification ………………..
6
Programming the ArgoxScan……………………..
9
Chapter 2 Parameter Setting
Interface
Interface Selection …………………………………..
11
USB HID Keyboard……………………………….…
12
RS-232 …………………………………………….….
15
Pin Assignments …………………………………….
18
System Control
Scan mode...………………………………………….
19
Indication …………………………..…………………
25
Code Option
UPCA ……………………………………..………….
27
UPCE …………………………………………………
32
EAN-13 ……………………………………………….
36
EAN-8 …………………………………………………
40
Code 39 ………………………………………………
44
Interleaved 2 of 5 ……………………………………
49
Industrial 2 of 5 ………………………………………
50
Matrix 2 of 5 Eur ……………………………………
52
Codabar ………………………………………………
54
Code-128/GS1-128 …………………………………
57
Code-93 ………………………………………………
61
Code-11 ………………………………………….……
64
MSI/Plessey ………………………………………….
66
UK/Plessey …………………………………………..
69

3
Telepen ……………………………………………….
71
Standard 2 of 5 ………………………………………
73
China Post ……………………………………………
75
Italian pharmacode ………………………….………
77
GS1 Data Omniidirectiona (RSS-14)……..……….
79
GS1 Databar Limited (RSS- Limited )………..……
81
GS1 Databar Expanded (RSS-Expanded) ………..
83
String Format
String Setting / Transmission
(Prefix/Suffix)…………………………………………
85
String Setting / Transmission
(Preamble/Postamble)………………………………
87
String Setting / Transmission
(Insert Group Characters)…………………………..
89
String Setting / Transmission
(Others)…….…………………………………………
93
Datamagic…………………………………………….
95
Appendix
Test Chart …………………………………………….
101
ASCII Code Table ……………………………………
104
Parameter setting List ……………………………….
105

4
Introduction
Installation RS-232
1) Disconnect power to the terminal/computer.
2) Connect the appropriate interface cable and external
power supply (DC adapter) to the scanner.
3) Plug the serial connector into the serial port on the back
of your computer/terminal. Tighten the two screws to
secure the connector to the port.
4) Plug the power pack into a power source.
5) Once the scanner has been fully connected, turn the
terminal/computer power back on.
USB HID (Simulate with keyboard wedge)
1) Connect the USB cable between scanner and PC.
2) Windows will automatically detect the USB device.
USB Com
1) Connect the USB cable between scanner and PC.
2) Windows will automatically detect the USB device.
Note: If any of the above operations is incorrect, turn off the
power immediately and check any improper
connections. Go through all above steps again.

5
Default setting
For each barcode shown as below:
Code Type
Read
Enable
Checksum
Verification
Enable
Checksum
Transmission
Enable
Code
ID
3000
UPC-A
V
V
V
A
UPC-E
V
V
V
E
EAN-13
V
V
V
F
EAN-8
V
V
V
FF
Code-39
V
*
Interleaved
2 of 5
V
i
Industrial
2 of 5
-
-
i
Matrix 2 of 5
B
Codabar
%
Code-128
V
V
#
Code-93
V two digits
&
Code-11
VOne digit
O
MSI/Plessey
V
@
UK/Plessey
V
@
Telepen
S
Standard 2 of 5
-
-
i
GS1databar
Omnidirectiona
-
-
R4
GS1databar
Limited
-
-
RL
GS1databar
Expanded
-
-
RX
China Post
t
Italian
Pharmacode.
p

6
Weight
85 g (cable not included)
Interface
USB COM/ USB HID /RS-232
Case material
ABS
Cushion material
TPR
Electrical
Input Voltage
5 VDC ± 0.25V
Power - Operating
850mW
Power - Standby
250 mW
AR-3000
Operational
Light Source
623 nm Visible Red LED
Optical System
2500 pixel CCD (Charge-coupled device)
Depth of Scan Field
0-85 mm (code 39, PCS=90%, 20mils)
Scanning Width
50 mm at 10mm
Scan Speed
300 scans/sec
Resolution
3mil Code39,PCS=90%
Print Contrast
30% or more
Scanning Angle
Pitch: ±60° Yaw: ±30°
Decode Capability
Auto-discriminates all standard
barcodes; Other symbologies can be
ordered optionally
Beeper Operation
7 tones or no beep
Indicator
Blue LED
Mechanical
Length
163mm
Width-head
75 mm
Depth-head
50 mm

7
Current - Operating
200 mA@5 VDC
Current - Standby
60 mA@5 VDC
Physical and Environment
Operating
Temperature
0℃to 50℃(32℉to 122℉)
Storage
Temperature
-20℃to 60℃
(-4℉to 140℉)
Humidity
5% to 90% relative humidity,
non-condensing
Light Level
Up to 20000 Lux.
Impact resistance
1.5m drop to concrete
EMC regulation
FCC Class A,CE, BSMI

8
Programming
Programming
method
Scan Utility
Manual (Reading special barcode)
DOS command through RS-232,
Windows configuration program
Program upgrade
Enabled built-in flash memory
Programmable
characteristics
Code type selection, check digit
selection, Decoding option Transmitted
character delay, Message suffix, Good
read beep tone and volume, Scanner
trigger selection, interface type ,Data
Editing

9
Programming the AR-3000
To program the AR-3000, you must scan a series of
programming barcode in the correct order. On the last page
of this manual, you will see a table of alphanumeric barcodes,
which are used to program the various options presented.
To program each option, you must:
1. Scan the Program barcode on the parameter setting part.
2. Enter the option mode by scanning the Option Bar Code
(also on the Parameter setting part).
3. To the right of the option barcode, the necessary
alphanumeric inputs are listed. Scan these alphanumeric
entries from the last page . To confirm above steps, you
must scan the Finish barcode on the last page.
4. Once you have finished programming. Scan the Exit
barcode, listed on the lower right hand corner of each
parameter setting part.
Table of contents
Other ArgoxScan Barcode Reader manuals



















