Areca ARC-4038 Series User manual

ARC-4038 series
(8/12-Bays 12Gb/s SAS Tower JBOD Enclosure)
SAS JBOD Enclosure
USER’S Manual
Version: 2.0
Issue Date: September, 2017

Copyright and Trademarks
The information of the products in this manual is subject to change
without prior notice and does not represent a commitment on the part
of the vendor, who assumes no liability or responsibility for any errors
that may appear in this manual. All brands and trademarks are the
properties of their respective owners. This manual contains materials
protected under International Copyright Conventions. All rights
reserved. No part of this manual may be reproduced in any form or by
any means, electronic or mechanical, including photocopying, without
the written permission of the manufacturer and the author.
FCC Statement
This equipment has been tested and found to comply with the lim-
its for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against in-
terference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interfer-
ence will not occur in a particular installation.
Manufacturer’s Declaration for CE Certication
We conrm ARC-4038 series has been tested and found comply with
the requirements set up in the council directive on the approximation
of the low of member state relating to the EMC Directive 2004/108/EC.
For the evaluation regarding to the electromag-netic compatibility, the
following standards where applied:
EN 55022: 2006, Class B
EN 61000-3-2: 2006
EN 61000-3-3: 1995+A1: 2001+A2: 2005
EN 55024:1998+A1:2001=A2:2003
IEC61000-4-2: 2001
IEC61000-4-3: 2006
IEC61000-4-4: 2004
IEC61000-4-5: 2005
IEC61000-4-6: 2006
IEC61000-4-8: 2001
IEC61000-4-11: 2004

Contents
1. Introduction ................................................................ 4
1.1 Overview ..........................................................................4
1.2. Features ..........................................................................6
2. Hardware Installation ................................................. 8
2.1 Before You First Installing....................................................8
2.2 ARC-4038 JBOD Enclosure View ...........................................9
2.3 Locations of the Subsystem Component .............................. 11
2.3.1 Drive Tray LED Indicators ............................................. 11
2.3.2 SAS Host/Expander LED Indicators ................................ 12
2.4 Installation...................................................................... 13
3. CLI Features.............................................................. 19
3.1 Expander RS-232C Port Pin Assignment .............................. 19
3.2 Start-up VT100 Screen ..................................................... 20
3.3 CLI Command ................................................................. 23
• HELP Command ................................................................ 23
• PASS Command ................................................................ 24
• LO Command ................................................................... 24
• LINK Command ................................................................ 24
• EDFB Command (Same as “DHPM”)..................................... 27
• TH Command ................................................................... 28
• GROUP Command ............................................................. 30
• SYS Command.................................................................. 31
● BU Command ................................................................... 33
• FAN Command.................................................................. 34
• SPIN Command ................................................................ 35
• ST Command.................................................................... 36
• LSD Command.................................................................. 36
• SHOWLOGS Command....................................................... 38
• FDL Command .................................................................. 39
• Counters Reset Command .................................................. 40
• Sasaddr Command ............................................................ 42
• Sub Command.................................................................. 42
• CON Command ................................................................. 43

INTRODUCTION
4
1. Introduction
This section presents a brief overview of the ARC-4038 compact tower
12Gb/s SAS JBOD enclosure.
1.1 Overview
The ARC-4038 SAS-to-SAS JBOD box provides a compact external
storage chassis capable of accommodating up to 8/12 12Gb/s Se-
rial-Attached SCSI (SAS) drives or 6Gb/s Serial ATA (SATA) drives.
The box can support both 3.5-inch disk drives and 2.5-inch disk
drives, each one contained in its individual hole on the disk carrier.
The expander module on ARC-4038 is designed with an integrated
ARM Cortex-R4 processor for topology management functions such
as discovery, enclosure and drive management, and LED manage-
ment. Each ARC-4038 compact tower JBOD supports four 12Gb/s
SFF-8644 and one 6Gb/s SFF-8088 SAS host and expansion con-
nections. Out-of-band CLI can re-dene manufacture default set-
ting on those connections. Conguration and environmental in-
formation is accessible either via in-band (SES-3.0 over SMP) or
out-of-band serial port.
Unparalleled Performance
The 12Gb/s ARC-4038 offers 28 ports of connectivity in a 8/12-bay
desktop tower. It can provide internally connectivity for up to 8/12
direct attached SAS/SATA HDDs and or SSDs and 20 external ports
(using 4 x SFF-8644 and 1 x SFF-8088 connector) for storage host/
expansion connections. High performance architecture sets new
boundaries of industry performance expectations: 12Gb/s SAS or
6.0Gb/s and 3Gb/s SAS/SATA. The ARC-4038 incorporates the lat-
est enhancements in SAS along with new LSI DataBolt bandwidth
optimizer technology. This is designed to help facilitate the indus-
try transition to 12Gb/s SAS-enabled systems by allowing users
to take advantage of 12Gb/s speeds while utilizing existing 6Gb/s
drives and backplanes. Using DataBolt, the ARC-4038 buffers
6Gb/s data and then transfers it out to the host at 12Gb/s speeds
in order to match the bandwidth between faster hosts and slower
SAS or SATA devices.

INTRODUCTION
5
Easy Management
The ARC-4038 contains an embedded expander manager that can
access via in-band SES-3.0 over SMP protocol and out-of band RS-
232 port. An out-of-band serial port is available for managing the
conguration and monitoring the expander. The ARC-4038 expand-
er rmware and EPLD has implemented the SES-3.0 protocol and
disk activity map to the individual fault/activity status indicator on
the backplanes. It has implemented autonomous chassis manage-
ment of power supply status connectors, two fan monitor/speed
control connectors through the SES-3.0 protocol. In data center
environments, identifying issues with drives and environments are
crucial. The hardware monitor can monitor system voltage and em-
perature. The warning message will be shown in alarm buzzer and
respect LED.
Maximum Interoperability
Areca presents its ultra-high performance and high reliability
12Gb/s SAS expander module for a cost-effective and enterprise-
class JBOD storage enclosure. A 12Gb/s SAS expander module
literally expands the number of end devices that you can connect
together. Expander devices, typically embedded into an expander
module to connect system backplane, support large congurations
of SAS end devices, including SAS host/RAID adapters and SAS
and SATA disk drives. The SAS protocol denes a mechanism that
has been implemented in the SAS expanders to guarantee fair ac-
cess between drives in a domain. The ARC-4038 is ideal for 12Gb/s
SAS storage systems with external interfaces and get the benets
of more storage capacity. The type and total amount of drives you
use are based on the host interface in the server that the JBOD is
connected. Host-based RAID conguration is supported via an ex-
ternal connectors on PCIe to 12Gb/s SAS RAID controller, external
series SAS/Fibre/iSCSI to 12Gb/s SAS RAID and SAS host adapt-
ers.

INTRODUCTION
6
1.2. Features
Drives
SAS hard drives
• Up to 8/12 2.5-inch or 3.5-inch SAS hot-plug hard drives
(12.0 Gb/s) at speeds of 7.2K, 10K or 15K rpm
SATA hard drives
• Up to 8/12 2.5-inch or 3.5-inch SATA hot-plug hard drives
(12.0 Gb/s) at speeds of 7.2K or 10K rpm
JBOD Controller Module
Expander board 1 module
Sensors 1 sensor
Backplane Board
Connectors
• 8/12 SAS hard-drive connectors
• 1 power supply connector
• 2 cooling fan module connectors
• 1 sets of expander board connector
Controller Back-Panel Connectors
I/O connectors
• 2 x SFF-8644 "Host In" connectors for connection to the host
• 1 x SFF-8088 "Host In" connectors for connection to the host
(only for 8-bays enclosure)
• 2 x SFF-8644 "Expansion Out" connectors for expansion to an
additional JBOD enclosure
Management connectors
• 1 x 6-pin UART RJ-11 connector
• 1 x RJ-45 LAN connector (manufacture manager only)
LED Indicators
Hard-drive carrier
• 1 blue single-color activity LED status indicator
• 1 two-color fault/power LED status indicator

INTRODUCTION
7
Expander board
• 2 x One-color LED status indicators for each SAS host port, one
for SAS host port link and one for the activity status
• 2 x One-color LED status indicators for each SAS expansion port,
one for SAS expansion port link and one for the activity state
Power Supplies
• Wattage 220 W maximum continuous
• Voltage 90–256 V rated
• Frequency 50–60 Hz
• Amperage +12V/16A, +5V/16A, +3.3V/14A
Cooling Fan
• Speed 2 X 2700rpm/brushless fan
• Amperage 2 X 0.135A
Physical
ARC-4038-8
• Height 302 mm
• Width 146 mm
• Depth 290 mm
• Weight 14.9lbs/6.8 kg (without disk)
ARC-4038-12
• Height 310 mm
• Width 206 mm
• Depth 290 mm
• Weight 20.8lbs/9.5 kg (without disk)
Environmental
Temperature:
Operating 0° to 40°C
Storage –40° to 60°C
Relative humidity:
Operating 10% to 80% (non-condensing)
Storage 5% to 95% (non-condensing)

HARDWARE INSTALLATION
8
2. Hardware Installation
This section describes how to install the ARC-4038 compact tower
12Gb/s SAS JBOD enclosure with host computer and disks.
2.1 Before You First Installing
Thanks for purchasing the ARC-4038 as your compact tower JBOD
data storage enclosure. The following manual gives simple step-by-
step instructions for installing and conguring the ARC-4038 JBOD
enclosure.
Unpack
Unpack and install the hardware in a static-free environment. The
ARC-4038 JBOD enclosure is packed inside an anti-static bag be-
tween two sponge sheets. Remove it and inspect it for damage. If
the ARC-4038 JBOD enclosure appears damaged, or if any items of
the contents listed below are missing or damaged, please contact
your dealer or distributor immediately.
Checklist
• ARC-4038 8/12-bays compact tower JBOD enclosure
• SFF-8088 to SFF-8088 cable (optional)
• SFF-8644 to SFF-8644 cable (optional)
• 1 x Power cord
• 1 x RJ11 to RS-232 DB9 cable
• 1 x RJ-45 LAN cable
• 32/48 x drive mounting screws (4 per drive tray)
• 1 x ARC-4038 quick installation guide

HARDWARE INSTALLATION
9
Front View Rear View
1. Disk Activity LED
2. Disk Fault/Power LED
3. System Fan
4. SAS Host Port0 (CH0)*
5. SAS Host Port1 (CH1)*
6. SAS Expansion Port0 (CH2)*
7. SAS Expansion Port1 (CH3)*
8. SAS Host Port2 (CH4)*
9. RS232 Port
10. LAN Port
11. Power Supply Fan
12. Power Connector
13. System Fan
14. On/Off Switch
2.2 ARC-4038 JBOD Enclosure View
The following diagram is the ARC-4038-8 compact tower JBOD en-
closure front view and rear view.
* Note: This is the default conguration. You can use the CLI to set it
as a expansion port or host port.

HARDWARE INSTALLATION
10
The following diagram is the ARC-4038-12 compact tower JBOD
enclosure front view and rear view.
Front View Rear View
1. Disk Activity LED
2. Disk Fault/Link LED
3. SAS Host Port0 (CH0)*
4. SAS Host Port1 (CH1)*
5. SAS Expansion Port0 (CH2)*
6. SAS Expansion Port1 (CH3)*
7. RS232 Port
8. LAN Port
9. On/Off Switch
10. System Fan
11. System Fan
12. Power Connector
* Note: This is the default conguration. You can use the CLI to set it
as a expansion port or host port.