Araknis Networks 300 Series User manual

300 - SERIES NETWORK SWITCHES
Installation Guide
Managed IT Rack Network Switches

© 2014 Araknis Networks®
2
FCC Warning
Pro Tips
Notes
CE Warning
Cautions
About This Manual
UL
Warnings
This device has been tested and found to comply with limits for a Class A digital device, pursuant to
Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment
generates and radiates radio frequency energy that will be required to correct interference at their
own expenses.
This is a Class A product. In a domestic environment this product may cause radio interference, in
which case the user may be required to take adequate measures.
This device is intended for indoor use only. It should not be connected to an Ethernet network with
outside plant routing.
This manual was created to provide a reference for installers and end users of Araknis Networks
products. It provides all known information regarding the installation, setup, use, and maintenance
of the product. This manual was created expressly for electronic use, but has been formatted so
that it may be printed and bound using either one-sided or front-and-back printing.
The symbols on the next page are used in this manual to identify certain information. Review the
denition of each symbol type to better understand notes later in the text.
Pro tips are included in sections of the manual to add information that provides extra value,
utility, or ease-of-use for the installer or end user of the product. Pro tips may also link to extra
information that will provide a better understanding of application, technology or use of the product
or feature in question. These items are not required, but have been added for your convenience.
Notes emphasize information important to the installation, setup, or use of the product that is
not essential to follow for safety of the equipment or user. Notes may be located before or in the
midst of the section they apply to, depending on the type of information. These items are usually
essential information, like the size or dimension of a separate part required, or a critical step in the
process, that, if missed, would cause the installer or end user extra work to overcome.
The caution symbol is used to indicate information vital to the safety of the equipment in use with
the product, or the product itself. Cautions are always provided before the information they relate
to. Not following a caution will almost always result in permanent damage to equipment that is not
covered by warranty.
Warnings indicate information vital to the safety to the installer or end user of the product.
Warnings are always provided before the information they relate to. Not following a warning may
result in permanent damage to equipment and serious injury or death of the installer or end user.
CERTIFICATIONS AND WARNINGS

www.snapav.com | Support: 866.838.5052
3
2
2
2
2
2
2
2
FCC Warning
Certications and
Warnings
2
Table of Contents 3
CE Warning
UL
Pro Tips
Notes
Cautions
Warnings
About This Manual 2
Introduction 4
Welcome to Araknis®Networks 4
Araknis®300-Series Overview 4
Installation 6
9
Package Contents 5
6
8
Recommended for Installation 5
8
9
10
Front Panel Layout
Side Panel Layout
Rack Mounting
Wall Mounting
Rear Panel Layout
Shelf Mounting
TABLE OF CONTENTS
Management 12
12
11
11
13
17
Specications
300-Series Managed Switch Specications 13
15
Warranty 17
Contacting Technical Support 17
Appendix
300-Series Managed PoE Switch Specications
Installation
Accessing Switch Management
Powering the Switch

© 2014 Araknis Networks®
4
Thank you for choosing an Araknis 300-series Network Switch. The 300-series managed network
switch is an enterprise-class switch specically designed for use in Ethernet applications within
the IT market.
With front-facing indicators and ports, the 300-series switch was designed for easy installation and
high performance in an environment where trafc on the network and the number of users could
increase continuously. The switch provides 10/100/1000Mbps capability on all ports and operates
as a plug-and-play device, auto detecting connections to other switches and allowing straight-
through patch cables throughout an installation. An intuitive GUI (Graphical User Interface) allows
for quick and easy conguration of the switch’s powerful features.
PoE models provide full PoE functionality. The PoE power budget in the AN-300-SW-F-8-POE /
-16-POE / -24-POE provides 15W on each port simultaneously. This helps the systems integrator
save time and effort calculating the available power budget as more PoE devices are added to
the switch.
The following table lists the models available in the 300-series family of network switches.
Model
Number of
Ethernet
Ports
Number of
PoE Ports
Number of
SFP Ports
Internal/External
Power Supply
AN-300-SW-F-8 8 0 2 Internal
AN-300-SW-F-16 16 0 2 Internal
AN-300-SW-F-24 24 0 2 Internal
AN-300-SW-F-8-POE 8 8 2 Internal
AN-300-SW-F-16-POE 16 16 2 Internal
AN-300-SW-F-24-POE 24 24 2 Internal
This Installation Guide will guide you through the layout of the device, and show the basic
steps for using the switch.
For more information, visit www.snapav.com.
Welcome to
Araknis® Networks
Araknis® 300-Series
Overview
INTRODUCTION
Individual ports can provide up to 25W, but this will affect the available PoE budget for other
ports. Each PoE model can provide 25W on half of the available ports at the same time.

www.snapav.com | Support: 866.838.5052
5
Package Contents
Recommended for
Installation
AN-300-SW-F Gigabit Ethernet Switch (1)
Quick Installation Guide (1)Color-coding Decals set (1)
AC Power Cord (1) Rubber Feet for at surfaces (4) Rack-Mount Kit (1)
·#2 Phillips screwdriver (for mounting ear installation)
·Screws and anchors for wall-mount installation optional; use a material that is fastener rated,
specied for use in the wall, and can safely hold the weight of the model in use
·Rack screws (optional; use screws designed for the rack in use)
·Drill (optional; for installation of wall-mount screws or anchors)
INTRODUCTION
Note: For wall mounting, It’s recommended to use #8x1-1/4 in. Coarse Phosphate-
Plated Steel Bugle-Head Phillips Drywall Screws and Anchors.

© 2014 Araknis Networks®
6
Mounting Options
or
Standard Protruding Recessed
Note: All product pictures in the document are for AN-300-SW-F-16-POE as an
example of the 300-series product line.
Rack Mounting
INSTALLATION

www.snapav.com | Support: 866.838.5052
7
• Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with the
maximum ambient temperature of 104°F.
• Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air
ow required for safe operation of the equipment is not compromised.
• Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
• Circuit Overloading - Consideration should be given to the connection of the equipment to
the supply circuit, and the effect that overloading of the circuits might have on overcurrent
protection and supply wiring. Appropriate consideration of equipment nameplate ratings should
be used when addressing this concern.
• Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections to the
branch circuit (e.g. use of power strips).
Rack Mounting
Guidelines
Rack Mounting
(Continued)
INSTALLATION

© 2014 Araknis Networks®
8
Wall Mounting
Shelf Mounting Caution: Do not stack more than 4 switches together. Do not stack any other equipment
on top of the network switch to avoid possible interference or damage.
INSTALLATION

www.snapav.com | Support: 866.838.5052
9
Front Panel Layout
Rear Panel Layout
LED Behavior Description
1 Gbps
Off
No device is connected/
Connected device
supports 10/100M speed
On Device is connected at
1Gbps speed
1. 1 Gbps LED Indicator (for non-PoE Models)
PoE LED Indicator
(for PoE Models)
Off No PoE device is
connected
On PoE-enabled device is
connected
2. PoE LED Indicator (for PoE Models)
Behavior Description
Off Power is off
On Power is on
4. Power LED Indicator
Behavior Description
Off No device is connected
Blinking Device is connected and
trafc is running
3. Link/Act LED Indicator
4. Ethernet Ports (RJ45)
Connect Ethernet network cables routed to equipment.
5. SFP Ports
Port for AN-ACC-SFP-E-100 or AN-ACC-SFP-MMF-350
4 5
2
1
3
3
4
4
1. Master Power Switch
Toggle Switch for master power control.
2. Power Jack
Attach an IEC power cable.
INSTALLATION

www.snapav.com | Support: 866.838.5052
10
Side Panel Layout
1. Ventilation Slots
Allows airow through the chassis to keep the device cool.
2. Rack Mounting Holes
The combination of threaded holes at the front and rear of each side allow for many
variations in mounting options.
1. Ventilation Slots
Allows airow through the chassis to keep the device cool.
2. Rack Mounting Holes
The combination of threaded holes at the front and rear of each side allow for many
variations in mounting options.
1
1
2
2
Non-PoE models
PoE models
Note: The PoE model shown above is for AN-300-SW-F-24-POE. 8-port and 16-
port models have only one fan.
This manual suits for next models
6
Table of contents
Other Araknis Networks Switch manuals

Araknis Networks
Araknis Networks 920 Series User manual

Araknis Networks
Araknis Networks 210 Series User manual

Araknis Networks
Araknis Networks 210 Series User manual

Araknis Networks
Araknis Networks 100 Series User manual

Araknis Networks
Araknis Networks 210 Series User manual

Araknis Networks
Araknis Networks AN-210-SW-C-8-POE User manual

















