Aquavitro sentia dose User manual

sentia™ dose
User Manual
Manual de instrucciones / Manuel d’instructions / Manuale Istruzioni / Manual de instruções / Handleiding / Bedienungsanleitung / Руководство
пользователя / Instrukcja obsługi / Kullanım Kılavuzu / Hướng dẫn sử dụng /


Contents
Introduction 2
Parts Checklist 2
Power Supply & Connecting Units 3
Using the Included Mounting Bracket 4
Setting Up Doser Pump Heads and Tubing 4
The sentia™App 5
Setting Up Aquariums in the App 5
Adding sentia™ Devices to the App 6
Device Setup 6
Notes on Dosing Schedules 9
The Dashboard 9
Resetting the WiFi Conguration on the Primary Doser 10
Resetting the Memory Conguration 10

IMPORTANT SAFETY INSTRUCTIONS
WARNING - To guard against injury, basic safety precautions should be observed, including the following:
A) READ AND FOLLOW ALL SAFETY INSTRUCTIONS
B) DANGER: To avoid possible electric shock, special care should be taken since water is employed in the use of
aquarium equipment. For each of the following situations, do not attempt repairs by yourself; return the appliance
to an authorized service facility for service or discard the appliance:
1) CAUTION: If the appliance falls into the water, DON’T reach for it! First unplug it and the retrieve it. If electrical
components of the appliance get wet, unplug the appliance immediately. (Non-immersible equipment only)
2) If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source. (Non-
immersible equipment only)
3) Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended
to be wet.
4) Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or
damaged in any manner.
5) To avoid the possibility of the appliance plug or receptacle getting wet, position aquarium stand and tank or the
fountain to one side of a wall-mounted receptacle to prevent water
from dripping onto the receptacle or plug. A “drip-loop” shown in the
Figure A should be arranged by the user for each cord connecting an
aquarium appliance to a receptacle. The “drip-loop” is the part of the
cord below the level of the receptacle or the connector if an extension
cord is used, to prevent water traveling along the cord and coming in
contact with the receptacle. If the plug or receptacle does get wet,
DON’T unplug the cord. Disconnect the fuse or circuit breaker that
supplies power to appliance. Then unplug and examine for presence of
water in the receptacle.
C) Close supervision is necessary when any appliance is used by or near children.
D) To avoid injury, do not contact moving parts or hot parts such as heaters, reectors, lamp bulbs and the like.
E) Always unplug an appliance from an outlet when not in use, before putting on or taking off parts and before cleaning.
Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.
F) Do not use an appliance for other than intended use. The use of attachments not recommended or sold by the
appliance manufacturer may cause an unsafe condition.
G) Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.
H) Make sure an appliance mounted on a tank is securely installed before operating it.
I) Read and observe all the important notices of the appliance.
J) If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts
than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over,
pulled, or placed where the appliance plug and extension cord plug will be exposed to water.
K) This appliance has a polarized plug (one blade is wider than other). As a safety feature, this plug will t in a polarized
outlet only one way. If the plug does not t fully in the outlet, reverse the plug. If it still does not t, contact a qualied
electrician. Never use with an extension cord unless plug can be fully inserted. Do no attempt to defeat this safety
feature. EXCEPTION: This instruction may be omitted for an appliance that is not provided with a polarized attachment
plug.
SAVE THESE INSTRUCTIONS
sentia™ dose pumps are made in conformity with the national and international security laws.
Drip Loop
Appliance Aquarium
Power
Supply
Cord

CONSIGNES DE SÉCURITÉ IMPORTANTES
MISE EN GARDE : An de se protéger contre les blessures, des mesures de sécurité de base doivent être observées, y compris les suivantes.
A) LIRE ET OBSERVER TOUTES LES CONSIGNES
DE SÉCURITÉ
B) DANGER - Pour éviter tout choc électrique, une grande prudence est de rigueur. Dans chacune des situations suivant-
es, ne pas essayer de réparer l’appareil soi-même; l’expédier au fabricant pour réparation ou le jeter.
1) Dans le cas l’appareil tombe dans l’eau, ne pas se précipiter à le récupérer! Avant tout, débrancher-le de la prise.
Si les composants électriques se mouillent, débrancher-le immédiatement (Uniquement pour produits non-
submersibles).
2) Si l’appareil présente une fuite d’eau anormale, débrancher-le immédiatement de la source d’alimentation
(Uniquement pour produits submersible).
3) Examiner soigneusement l’appareil après l’installation. Il ne doit pas être branché s’il y a de l’eau sur les pièces
qui ne doivent pas être mouillées.
4) Ne pas faire fonctionner un appareil défectueux, dont le cordon électrique ou la che sont endommagés, ou qui a
été échappé ou abîmé d’une façon quelconque.
5) An d’éviter que l’appareil ou la prise de courant soient mouillés, installer le cabinet de aquarium et le bac à côté
d’une prise de courant pour empêcher l’eau de dégoutter sur la prise.
L’utilisateur devrait faire une boucle d’égouttement g. ci-dessous
pour chaque cordon électrique branché d’un aquarium à une prise de
courant. La boucle d’égouttement est la partie du cordon se trouvant
sous le niveau de la prise de courant (ou le raccord si une rallonge
électrique est utilisée), an d’empêcher que l’eau circule le long du
cordon électrique et entre en contact avec la prise de courant. Si la
che ou la prise de courant sont mouillées, NE PAS débrancher le
cordon électrique : débrancher d’abord le fusible ou disjoncteur qui
fournit l’électricité à l’appareil et débrancher ensuite l’appareil en
vériant qu’il n’y ait pas d’eau dans la prise.
C) Pour éviter les accidents, ne pas toucher les pièces en mouvement ou chaudes comme chauffages, réecteurs,
ampoules, etc.
D) Toujours débrancher l’appareil quand il n’est pas utilisé, quand des pièces doivent être enlevées ou remplacées et
avant l’entretien. Ne jamais tirer par le l pour débrancher l’appareil; prendre la che et débrancher l’appareil.
E) Ne pas utiliser un appareil pour un emploi autre que celui pour lequel il a été fabriqué. Les pièces non vendues ou non
recommandées par le fabricant pourraient compromettre la sécurité de l’appareil.
F) Ne pas exposer cet appareil aux intempéries ou à une température en dessous de 0 ºC.
G) S’assurer qu’un appareil monté sur un aquarium soit bien installé avant de le faire fonctionner.
H) Lire et observer tous les avis importants sur l’appareil.
I) Si une rallonge électrique est nécessaire, s’assurer qu’elle soit de la bonne taille. Un cordon électrique de taille inférieur
ou de moins d’ampères ou de watts que l’appareil peut surchauffer. Le cordon doit être placé de façon à éviter que
quelqu’un trébuche ou le tire involontairement.
J) Cet appareil possède une che polarisée (une lame est plus large que les autres). Par mesure de sécurité, cette che
s’insère dans la prise polarisée que dans un sens. Si la che n’entre pas complètement dans la prise, inverser la che.
Si elle ne rentre toujours pas, contactez un électricien qualié. Ne jamais utiliser une rallonge si la che peut être
insérée complètement. Ne pas essayer de contourner ce dispositif de sécurité.
K) Cet appareil possède une che polarisée (une lame est plus large que les autres). Par mesure de sécurité, cette che
s’insère dans la prise polarisée que dans un sens. Si la che n’entre pas complètement dans la prise, inverser la che.
Si elle ne rentre toujours pas, contactez un électricien qualié. Ne jamais utiliser une rallonge si la che peut être
insérée complètement. Ne pas essayer de contourner ce dispositif de sécurité. EXCEPTION: cette notice peut être
omise pour tout appareil ne pas muni d’une che polarisée.
CONSERVER CES INSTRUCTIONS
Les sentia™ dose pompes sont conforme aux normes de sécurité nationales et internationales.
Aquarium
Boucle d’égouttement
Appareil
Cordon
d'alimentation

READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1) Unplug the device before installing or carrying out any maintenance. Please check that the voltage and frequency
indicated on the device label corresponds to that of your electrical network. This electrical device must be powered
by a differential circuit breaker
2) Never operate the device without water to avoid damage to the pump’s components.
3) Before plugging in the device, check that the cord and the device are not damaged.
4) The adapter has a type Z cable link. The cable and the plug cannot be substituted or repair. In case of damage,
replace the entire device.
5) CAUTION: disconnect all submerged electrical products before doing maintenance in the water; in case the plug or
electrical outlet is damaged, switch off the circuit breaker before disconnecting the plug from the outlet.
6) This product is designed for indoor use only, and has an IP20 protection rating; it should not be turned on unless you
have ensured that the unit is a completely dry.
7) Never put the device in the water and place it where it CANNOT fall into the water or have contact with water.
8) This unit is non-submersible. To avoid the possible risk of electric shock place the unit in a dry place safe from
splashing, moisture and salt creep, where it can’t accidentally fall into water.
9) This product is designed for aquarium use only. Use in other applications may damage its components, voiding the
warranty immediately.
10) The device can be used with liquids or in environment with a temperature not higher than 35 °C / 95 °F.
11) Do not use the device for purposes (i.e. in bathroom or similar applications) other than for which it was designed.
12) Avoid device use with corrosive and abrasive liquids.
13) This device has not been designed for use by children or mentally challenged individuals. Appropriate adult
supervision or persons responsible for personal safety is required.
14) To prevent water from accidentally wetting the plug or electrical outlet, make a loop in the cord under the electrical
outlet level
INSTRUCTIONS FOR THE CORRECT DISPOSAL OF THE PRODUCT ACCORDING TO EU DIRECTIVE 2002/96/EC
When used or broken, this product does not have to be disposed with other waste. It can be delivered to specic electrical
waste collection centers or to dealers who provide this service. Disposal of electrical products separately avoids
negative consequences for the environment and for overall public health and allows the reuse of materials providing
savings of energy and resources.
LIMITED WARRANTY
Seachem guarantees this product (see Exclusions below) to the original purchaser against defects of materials and
workmanship for a period of three (3) years from the date of original purchase, and may be extended for an additional
two (2) years with registration of the product at www.registration.seachem.com; all terms excepting for the doser’s
pump head, which is guaranteed for a period of six (6) months. This warranty is limited to repair or replacement (at
Seachem’s discretion) of defective product only and does not cover loss of aquarium life, personal injury, property loss,
or damage arising from the use of the product. You must retain original proof of purchase to validate the warranty.
Any warranty herein shall run concurrently with, and not in addition to, any minimum warranty periods established by
applicable law.
Claims made under warranty shall be led online at www.seachem.com by the original purchaser and who must provide
proof of purchase at the time of ling. The claimant must obtain a “Return Merchandise Authorization” at the time of
ling before sending any product for warranty or technical service. The purchaser bears the cost of shipping to and
from the service center or repair station.

EXCLUSIONS. This warranty does not cover the following: *Damage resulting from accident, misuse, abuse, lack
of reasonable care, use of the product that is other than normal or ordinary, using the project in abnormal working
conditions or any other failures not resulting from defects in materials or workmanship. *Damage resulting from
modication, tampering with or attempted repair by anyone other than Seachem or its designee. * Transfer of the
product to someone other than the original purchaser. * Subjecting the product to electrical service not specied in the
packaging; the original purchaser is responsible for providing adequate electrical facilities.”
EXCLUSION DAMAGES AND LIMITATION OF IMPLIED WARRANTIES
Your sole and exclusive remedy is product repair or replacement as provided in this Limited Warranty. The company
disclaims any liability for incidental and consequential damages for breach of any express or implied warranty or
conditions, including the implied warranties or conditions of merchantability, merchantable quality, tness for a
particular purpose, or of satisfactory quality with respect to this product. This writing constitutes the entire warranty
agreement of the parties with respect to the subject matter hereof, no waiver or amendment shall be valid unless in
writing signed by Seachem. Any implied warranties herein are limited to one year or the shortest period allowed by the
law of your jurisdiction

Introduction
Parts Checklist
The sentia™dose primary and secondary dosers provide an unparalleled platform for the success of any aquarist
in keeping consistent parameter levels in any aquarium environment. The patented modularity and simplicity in
design offer affordability and expandability beyond any other doser system on the market. The dosers are easily
programmed and run using any smart phone with an app over Wi. A host of convenient and industry leading
features make the sentia™dose dosers the best choice in dosing systems for any aquarium.
A. sentia™dose Unit
B. Power Adaptor with Plugs Set (North American, EU,
UK and Australia/New Zealand) Primary Unit only
C. Colored Rings for Pump Head (Red, Orange, Yellow,
Green, Blue, Teal, Purple)
D. Colored Clips for Tubing (Red, Orange, Yellow, Green,
Blue, Teal, Purple)
A D
E F G H I
B C
x2 x2
x7x7
E. Tubing (3m)
F. Tubing Connectors (2)
G. Mounting Plate (1) and Screws (2)
H. Adhesive Strips for Mounting Plate (2)
I. Calibration Tube with Cap
Check the integrity of each component of the parts list prior to use.

Power Supply & Connecting Units
The sentia™dose Primary Control Unit includes a Power Adaptor and Plugs Set. The Plugs Set includes plugs
matching electrical outlets for North American, EU, UK and Australia/New Zealand locales or setups. To prepare
the Power Adapter for use, slide the appropriate Plug onto the Plug Adaptor rmly - the Plug should lock into place
securely. The Power Adapter supplies power to the the Primary Control Unit and any Secondary Units attached to
the Primary Control Unit.
Always make certain the Power Adapter is unplugged before connecting or disconnecting any Primary
Control Unit or Secondary Units in sequence.
To connect any unit in sequence simply remove the corresponding side plates of the units being connected (Figure
1.A) and slide the unit being connected to the right down onto the unit on the left (Figure 1.B). Replace all side
covers to any exposed sides once connections are complete.
Primary Control Units and Secondary Units can be connnected in any sequence or order. The connected units
sequence will always appear in the app list from left to right in a top-to-bottom arrangement with the left unit being
at the top of the list.
Once all units being used are connected in sequence and side covers are in place, the Power Adpator can be
plugged into any unit in the sequence. All units should have lights illuminate just above the Pump Head(s). A white
colored circle should be lit to the right above the Pump Head(s). A white WiFi emblem should show to the left above
the Pump Head on Primary Control Units. A white Link emblem should blink to the left on any Secondary Units - the
light(s) will blink in succession for any sequence of Secondary Units.
Figure 1.A Figure 1.B

Using the Included Mounting Bracket
Each sentia™dose Primary Control Unit and/or Secondary Unit includes a mounting bracket for optionally securing
the Unit(s) as desired. The included Mounting Plate can be secured with the included Screws or the included
Adhesive Strips. The Mounting Plates for any number of Units in sequence interlock to neighboring Units. Mounting
Plates should be secured in sequence to the mounting location. Once secured, the entire group of Units can be
attached to the line of Mounting Plates.
Setting Up Doser Pump Heads and Tubing
Placement of the sentia™dose Primary Control Unit and/or connected Secondary Unit(s) is unique to each user’s
circumstance. In general, the system should be set up for ease of access to any supplements being dosed while
being within a comfortable proximity to the aquarium or sump being dosed. Any length of tubing distance is
generally feasible given proper calibration of the solution being dosed.
Additionally, the Pump Head can be adjusted to 8 different positions by turning the Pump Head gently clockwise
to unlock its position. The Pump Head can then be turned to the various other positions and then locked back
into place by lowering it into the chosen position and turning it counter clockwise. This allows the Unit(s) to be
positioned horizontally, vertically, diagonally, etc. to facilitate the best position for each user’s application. All
sentia™dose Primary Control Units and Secondary Units come with the Pump Head already assembled.
Connect a Tubing Connector to each end of the Pump Head tubing. When facing the Pump Head directly the ow
through the doser is in through the Right Tube and out through the Left Tube. Approximately 1 meter of Tubing is
included with each Primary Control Unit and Secondary Unit. Install the appropriate length of tubing required from
the supplement reservoir or bottle to the inow side (Right Tube when facing Unit) of a unit making certain that
the length of tubing extends all the way to the bottom of the resevoir easily. Install the appropriate length of tubing
required from the Primary Control Unit and/or connected Secondary Unit outow side (Left Tube when facing Unit)
to the aquarium or sump being dosed. Make certain the line is secure and that the output end of the line is above
the water line. Additional tubing is available in 3 meter segments as an accessory from your dealer.
Colored Rings for Pump Heads are intended to coordinate with the Colored Clip for each tube run to avoid confusion
when using multiple dosers. The Pump Head Colored Ring can be removed by lightly pulling up at the indention
where the Colored Ring meets the Pump Head. Simply replace the Colored Ring as desired and press down on the
Colored Ring to secure it to the Pump Head. A corresponding Colored Clip can then be installed on the end of the
output line at the aquarium or sump being dosed.
Table of contents
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual