AP&T AP-DJ1811 User manual

Intelligent control ionizing air blower
AP-DJ1811
Shanghai Anping Static Technology Co.,Ltd
AP&T
R
AP&T
New Product
Intelligent Control Ionizing Air Blower

Effectively solve the problems
caused by static electricity
Suitable for electronics, optoelectronics,
semiconductor and other industries
Prevent adhesion of objects
Static removal Prevent blockage of feeder
Prevent static electricity
Prevent material splash

Network Monitoring
Multiple networking methods to monitor the
working status of ionizing air blower online
RS485
communication
AP-DY6703
AP-KT3701 AP-DY6704
USB wire link
USB wire link
IMS monitoring software
IMS monitoring software
IMS monitoring software

Intelligent Remote Control
Cleaning time /Air volume output adjustable
Cleaning time setting
Set a reminder for the cleaning time at will. Blue light flashes indicates cleaning is required. The electrode needle
cleaning cycle should be set according to the working environment when using the ionizing air blower. Cleaning
cycle should be shorten appropriately in environment with more moisture and dust.
Air volume output adjustable
Fan speed in five gears. Adjust the air volume according to the installation distance of the static eliminator and the
status of the target object.
Ion balance adjustable
The ion balance voltage can be adjusted by adjusting the negative high voltage
amplitude remotely.
Function Symbol Operation instructions
Unlock Unlock before adjusting operating parameters; 30s delay if any key is
pressed, exit and re-locked if no key is pressed.
Run / Pause Device starts running when power is on. Press "STOP" to standby and no
high voltage output. Press "RUN" again and the device will start working.
Clean Press the button to clean the needle once.
Adjust clean time CTTH → +/- Press CTTH first, and then press +/- to increase or decrease the
cleaning cycle. Minimum adjustment unit 1H.
Adjust air volume CFM → +/- Press CFM first, then press +/-,air volume from high to low is 1,2,3,4,5.
Adjust ion balance IBN → +/- Press IBN first, then press +/- to adjust the ion balance voltage.
Confirm CAL → OK Note: Press CAL first, then press OK to confirm after adjusting the
output parameter; otherwise, false alarms are likely to occur.
Reset Reset(150Hz、50%、4H):Press CAL first,then pressPress IBN first, then press + when the positive voltage on flat panel charge detector or object surface is high, press IBN first, then press - when
the negative voltage on flat panel charge detector or object surface is high until the ion balance reaches the ideal status.
CAL →
TIME TIME
Reduce the negative high voltage amplitude,
the negative ion output decreases
Adjust ion balance voltage
Button Function instructions

Pulse DC
Discharge effect is better compare to
frequency AC ionizing air blower
Pulse DC method generate ions with two polarity by
applying "+" and "-" high voltage alternately on positive
and negative electrode needles.
Compared with power frequency AC method, the
utilization rate of ion generation is higher. And its static
elimination ability can be exerted no matter in short or
long distance. In addition, the high voltage amplitude
can be adjusted, which is convenient for intelligent
control.
Pulse DC VS Traditional AC
AC
High voltage power supply
Power frequency AC
T
+HV
(Positive high voltage)
-HV
(Negative high voltage)
Pulse DC
Pulse DC
Positive pulse Negative pulse
T
Pulse DC
Positive voltage working time
Negative voltage working time
+HV
(Positive high voltage)
-HV
(Negative high voltage)
Positive voltage working time
Negative voltage working time

Keep a clean production environment and stay
away from static electricity
Ion balance distribution diagram of AP-DJ1811
Discharge time distribution diagram of AP-DJ1811
Note:The 0 point of the test length is the center position of the
air blower
Test standard:ANSI/ESD.STM3.1,SJ/T 11446—2013
Test instrument: Trek charge plate tester
Test voltage:±1000V → ±100V attenuation
Test environment:humidity 50±5%;temperature 23±3℃
Test bearing chart of single-port air blower
Z(mm)Trek 150*150mm flat tester
-150
X(mm)
150mm
300mm
450mm
900mm
600mm
750mm
150
0
-150 0 150
900
750
600
450
300
150
Test Height (mm)
0.4
1.5
2.7
3.8
5
6.2
7.3
8.4
9.6
11
12
Discharge Time(s)
Test Length (mm)
-150 0 150
900
750
600
450
300
150
-9
-7
-6
-4
-3
-1
0
2
3
5
Ion Balance(V)
High Efficiency Static Removal
Test Length (mm)
Test Height (mm)

No.1
No.2
No.4
Intelligent remote control
Ion output characteristics can be adjusted by remote
control.
8 Electrode needles
Multiple air outlets, 8 tungsten
electrode needles per air outlet with
longer life time.
No.3
Built-in cleaning brush
Automatic needle brushing function when start up. By
default, the needle is automatically brushed every 4 hours
for manual cleaning and maintenance free.
High voltage alarm
Display screen show fault alarm and LED red
light alarm when the fan and high voltage
breakdown.
Features
Safe / Easy to use / Durable

No.5
No.6
No.7
LED display
LED display shows the equipment address (e.g.A00),
wind speed gear (e.g.S1), cleaning cycle (e.g.T04),
temperature and humidity, cleaning indication (Cleaning),
fan fault alarm (Fan Fault!!) and HV fault alarm (HV
Fault!!)
High air volume fan five
speed adjustment
Stable performance and air volume output
1.45 times higher than ordinary fans.
CE certification
CE certified with electromagnetic protection function and
no electromagnetic interference to other equipment. It can
also effectively avoid external electromagnetic
interference affecting the normal operation of the air
blower which is a high-security and high-reliability static
eliminator.
No.8
Network Monitoring
Wired network communication
realisable and monitor the working
status of the air blower.
RS485
Communication
IMS monitoring software
Features
Safe / Easy to use / Durable

Temperature and humidity
(The temperature and humidity sensor is located inside the product)
Unlock / Lock
Run / Pause Fan No.
wind speed gear(5gears)
LCD display
Green light always on: normal Red light always on: fan fault alarm
Power interface cable function information
1、2 Orange
White-orange VCC:+24VDC
3Blue RS485+B
4White-blue RS485+A
5Green GND
6White-green GND
7Brown VTH:Sensor threshold alarm
HVAL:Eliminator high voltage alarm
8White-brown
Clean:Eliminator cleaning indication
9Metal shield PE
The output wiring diagrams of pins 7 and 8 are as follows:
8VKDSHGEUDFNHW
RJ45 power/communication interface
*URXQG6WXG
3RZHUVZLWFK
&OHDQingVZLWFK
$LUYROXPHDGMXVWPHQW
/('GLVSOD\
6WDWXV,QGLFDWRU
)URQW %DFN
%DNHOLWHVFUHZKDQGOH(0î)
)DQIURQWFRYHU )DQUHDUFRYHU
Product Use
3DQHOIXQFWLRQVspecificationGLPHQVLRQV
3DQHOIXQFWLRQV
Blue light flashes: cleaning indication
Blue light always on: pause/standby Red light flashes: high voltage fault alarm
Cleaning cycle
ACT:Sensor/eliminator power-on indication
HV Alarm signal:Normal--always open、Abnormal--always close Power signal :Normal--always close
cleaning signal:Clean--always open

Model AP-DJ1811
Input voltage DC 24V(RJ45 Interface)
Output voltage DC±4KV → ±6KV
Power 12W
Ion emission Pulse DC
Emitter electrode Tungsten alloy
Discharge range 750*300mm(L*W)
Air volume ≤ 135CFM*1
Noise Single air outlet≤ 58dBA(1000mm away from the air outlet)
Ozone thickness ≤ 0.05ppm(150mm away from the air outlet)
Ion balance ≤ |±10V|
Discharge speed ≤ 1.5S
(300mm away from the air outlet)
Status indicator
Power on/clean operation—blue light flashes;
Normal work—green light (always under monitoring status);
Fan fault alarm—red light always on;
High voltage fault alarm-red light flashes;
Infrared debugging/cleaning prompt-blue light flashing
Communication method RS485
Signal output RS485(115200bps,8,1,n,n)≥ 20ms
Collector open circuit:< 50V,100mA
Working temperature 0℃ -50℃
Working humidity < 70%RH
Dimensions 147*70.5*190mmmm(L*W*H)Ionizing Air Blower body size)
Shell material Aluminum powder spraying
Installation accessories 1 pair of U-shaped iron powder spraying mounting
brackets, 1 pair of bakelite screw handles(M5×8)
Power adapter INPUT:AC100—240V 50/60Hz;
OUTPUT:DC24V 2A(dual RJ45 Interface)
Weight 1.35KG(Including power cord and bracket)
Warranty 1Year
Certification CE
Specification
Unit:mm
Dimensions
Installation accessories
1 pair of U-shaped iron powder spraying
mounting brackets, 1 pair of bakelite
screw handles(M5×8)
147 70.5
156
190
200.5
60
152
117
Φ6.5×3
Φ6.5×2
102
30
10°
56 56
30
R6
20
1,5
60
20
Table of contents
Other AP&T Blower manuals

AP&T
AP&T AP-AC2459 User manual

AP&T
AP&T AP-DC2452-60C User manual

AP&T
AP&T AP-DJ1802 User manual

AP&T
AP&T AP-DC2451-001 User manual

AP&T
AP&T AP-DJ2812 User manual

AP&T
AP&T AP-DC2453 User manual

AP&T
AP&T AP-DC2453 User manual

AP&T
AP&T AP-DJ2814 User manual

AP&T
AP&T AP-DJ2813 User manual

AP&T
AP&T AP-DC2451-001 User manual