Anilam Wizard 211 User manual

P/N 70000421B
Wizard 211
Digital Readout
Operations Manual
WIZARD 211
FSET MM
INCH
ABS
INCR
2
9
75
4
1
0.+
-
3
86
SALES & SERVICE:
A Tech Authority, Inc.
13745 Stockton Ave.
Chino CA 91710
909-614-4522

iii
Warranty
ANILAM warrants its products to be free from defects in material and
workmanship for three (3) years from date of installation. At our
option, we will repair or replace any defective product upon prepaid
return to our factory.
This warranty applies to all products when used in a normal industrial
environment. Any unauthorized tampering, misuse, or neglect will
make this warranty null and void.
Under no circumstances will ANILAM, any affiliate, or related company
assume any liability for loss of use or for any direct or consequential
damages.
The foregoing warranties are in lieu of all other warranties expressed
or implied, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose.
System Purchased From: ____________________________
Console Part Number:_______________________________
Console Serial Number: _____________________________
Date of Installation: _________________________________
Feature, Operation, and Technology
WIZARD Digital Readouts provide the absolute latest in ease of
operation, capability, and technology. As a result, ANILAM may alter
and enhance operation, features, and capabilities without notice.
© Copyright 2004 ACU-RITE Companies Inc.

v
Contents
Contents ................................................................................................................................ iii
Introducing the Wizard............................................................................................................1
The ANILAM Wizard 211 Keypad and Display Windows .............................................2
The ANILAM Wizard 211 Back Panel...........................................................................3
First-Time User Checklist .......................................................................................................5
About This Manual..................................................................................................................7
Function Code List..................................................................................................................8
Beeper ....................................................................................................................................9
Keyboard Entry Error............................................................................................................10
Presetting a Dimension ........................................................................................................11
Resetting an Axis to Zero .....................................................................................................12
Recalling a Preset Dimension ..............................................................................................13
Clearing a Preset Dimension................................................................................................14
Centering the Workpiece ......................................................................................................15
Adding/Subtracting Values ...................................................................................................16
Dividing an Axis Value by 2 ..................................................................................................17
Inch/Metric Conversion.........................................................................................................18
Plus/Minus Key .....................................................................................................................19
Absolute/Incremental (ABS/INCR) Key ................................................................................20
Absolute/Incremental............................................................................................................21
Absolute Zero Set – F 01......................................................................................................22
EverTrackTM Mode – F 02.....................................................................................................23
Setting a Correction Factor – F 03 .......................................................................................27
Correction Factor OFF/ON – F 04 ........................................................................................28
Radius/Diameter per Axis – F 05..........................................................................................29
Approaching Zero Indicator ..................................................................................................30
Approaching Zero – F 06......................................................................................................31
Last Position Save/Recall – F 10/F 11 .................................................................................32

vi
Contents (Continued)
Axis Reset Only – F 16 .........................................................................................................33
Parameter Settings – F 20....................................................................................................34
Metric linear encoders .............................................................................................35
Inch Linear Encoders (BT or JB Linear Encoders)..................................................40
Beeper OFF/ON – F 21 ........................................................................................................41
Display Dim OFF/ON – F 22/F 23 ........................................................................................42
Axis Designation – F24.........................................................................................................43
Linear Encoder Error Detect OFF/ON – F 40/F 41...............................................................44
Diagnostics – F 45 ................................................................................................................45
Troubleshooting ....................................................................................................................47
Index .............................................................................................................................Index-1

1
Introducing the Wizard
Thank you for purchasing the ANILAM Wizard 211 Digital Readout (DRO).
Review these pages carefully to learn how to properly operate your new DRO.
The new DRO offers many features and capabilities never before used in conventional
DRO systems.
This manual was written with you, the operator, in mind. Please take the time to study
it. A little well-spent time now will ensure many years of trouble-free operation.
For additional information, please contact your local authorized ANILAM distributor, or
call us directly:
ANILAM, Inc.
One Precision Way
Jamestown, New York, U.S.A., 14701
Phone: (716) 661-1700
FAX: (716) 661-1884
http://www.anilam.com

2
Introducing the Wizard (Continued)
The ANILAM Wizard 211 Keypad and Display Windows
NOTE: The Wizard 211 DRO is available in one-axis, two-axis, and three-axis
models. For simplicity, the procedures in this manual describe only a
two-axis model.
WIZARD 211
FSET
MM
INCH
ABS
INCR
2
9
7
5
4
1
0
8
6
+
-
3
.
Display Windows
Key
Absolute/Incremental
MM/INCH Key
Function Key
Set Key
Plus/Minus Key
Numeric Keys
Axis Keys

3
Introducing the Wizard (Continued)
The ANILAM Wizard 211 Back Panel
Linear Encoder
Connections
Ground
Connection
Power Cord
Connection
ON/OFF Switch
Fuse Cover Slot
I
O
Selecting the Operating Voltage
To select the operating voltage for the DRO:
1. Locate the ON/OFF switch on the back panel of the DRO and verify that the switch
is in the OFF (0) position.
CAUTION:To avoid electrical shock, unplug the DRO from the power source.
2. Insert a small screwdriver into the fuse cover slot and open the fuse cover.
3. Remove the fuse holder. Depending on the desired operating voltage, place the
fuse in either the 115V slot or the 230V slot. For 115V, place the fuse on the right
and the clip on the left; for 230 V, place the fuse on the left and the clip on the right.
NOTE:Both the 5 X 20 mm fuse (Europe) and the ¼ X 1-¼ inch fuse (U.S.), rated at
0.5 amps/250V can be used in the fuse holder.
4. The selected operating voltage is visible through the fuse cover window.
5. Insert the fuse holder into the ON/OFF switch and close the fuse cover.

4
Introducing the Wizard (Continued)
Your Wizard’s display was designed to be easy to read:
ABS RST CF RI MM INCH
Axis Indicator
Indicates Z1
Coarse Resolution
Diameter Mode
Absolute Mode
Reset Only Axis
Correction Factor
Reference Indicator
MM or INCH Mode
Edge Sensor
Approaching Zero
Indicator

5
First-Time User Checklist
Your new DRO has many preset values. Before you proceed, please review the
following list to verify default settings. If you need to change any setting(s), refer to
Parameter Settings – F 20.
Description of Setting Factory Setting Your Setting
1. Mill/Lathe Operation MILL
2. Linear Encoder Resolution Axis 1 5 µm
Axis 2
5 µm
3. Direction of Count Axis 1 +
Axis 2
+
4. Position Tolerance Indicator Axis 1 Set to Zero
Axis 2 Set to Zero
5. Audible Keyboard Tone ON
6. Display Resolution Axis 1 .0002 inches (.005mm)
Axis 2
.0002 inches (.005mm)
7. Display Dimming 15 Minutes
8. Radius Diameter Mode Axis 1 Radius
Axis 2 Radius

6
First-Time User Checklist (Continued)
For your safety, and to prevent damage to the machine, please verify the following:
9. DRO arm and DRO are securely
mounted to the machine.
Yes/No
10. The DRO Input-voltage switch
on the power-entry module
(back panel) is set to the correct
input voltage.
Yes/No
11. DRO is properly grounded.
(Earth-ground to wall conduit or
water pipe, for example, not
grounded to the machine).
Yes/No
12. All cables are off the floor and
out of the range of moving parts.
Yes/No
Table of contents
Other Anilam Digital Readout manuals