AMS Alborz MicroSystem User manual

Alborz
MicroSystem
AMS-RE3011 RIO
Remote IO Module User’s Manual
Alborz Micro System
Industrial Control
& Monitoring
Power Distribution
Panel
Wireless Radio
Modem
Telemetry Control
Data Acquisition &
Transmission
Technical Support and
Contact Information:
alborzmicrosystem.com

AMS-E3011 RIO User’s Manual
AMS-E3011 Hardware User’s Manual
The documentation is copyrighted 2016 by Alborz Micro System Co., Ltd. All rights are reserved.
AMS Co., Ltd.
Trademarks
The Alborz Micro System logo is a registered trademark of AMS Inc.
All other trademarks or registered marks in this manual belong to their respective
manufacturers.
Disclaimer
Information in this document is subject to change without notice and does not represent a
commitment on the part of Alborz Micro System.
AMS provides this document as is, without warranty of any kind, either expressed or implied,
including, but not limited to, its particular purpose. AMS reserves the right to make improvements
and/or changes to this manual, or to the products and/or the programs described in this manual,
at any time.
Information provided in this manual is intended to be accurate and reliable. However, AMS
assumes no responsibility for its use, or for any infringements on the rights of third parties that
may result from its use.
This product might include unintentional technical or typographical errors. Changes are
periodically made to the information herein to correct such errors, and these changes are
incorporated into new editions of the publication.
Technical Support Contact Information
www.alborzmicrosystem.com

AMS-E3011 RIO User’s Manual
Table of Contents
1. Introduction
1.1. Overview
1.2. Package check list
1.3. Product Key Features
1.4. Specification
1.5. Hardware Block Diagram
1.6. Physical Dimensions
1.7. Appearance
1.8. LED Indicators
2. Initial Setup
2.1. Appearance
2.2. DIN-Rail Installation
2.3. Wall-mounted Installation
2.4. Device Address and Baud Rate Setting
2.5. Modbus Register Map
3. Module Specifications and Wiring
3.1. Power Supply
3.2. Analog Input
3.3. Digital Input
3.4. Digital Output
3.5. Serial Ports

AMS-E3011 RIO User’s Manual

AMS-E3011 RIO User’s Manual
1.1. Overview
Alborz MicoSystem provides a variety of solutions in the fields of software and hardware in SCADA
and Telemetric systems. In the hardware category, the RTU productions of the company are divided
into five categories of RTU100, IDL1000, MDL2000, AMS-R3000 and AMS-R4000, which they are
designed and developed for specific applications in the SCADA systems. In this document, we focus
on the features and capabilities of the AMS-E3011 Remote IO and how you can be benefited from
these features in your SCADA project.
1.2. Package check list
The AMS-E3011 ships with the following items:
• AMS-E3011 RIO Controller
• Quick Start
Optional Accessories (They can be purchased separately)
• R30-MSP: Male serial connection (3pin to DB9)
• R30-FSP: Female serial connection (3pin to DB9)

AMS-E3011 RIO User’s Manual
1.3. Product Key Features
Powerful Cortex-M3 industrial-grade CPU
Low power consumption
Support multiple industry standard
Support multiple communication protocols
4x 1KHz Counter
8x Digital Inputs
4x Digital Output
4x Analog Inputs
LED indicator for all of the inputs, outputs and communication status
Chatter Filter
Jitter Filter
Watchdog Timer
1.4. Specification
The AMS-E3011 RIO is a remote IO expansion module with a low power consumption feature
which is offered for using in SCADA systems with limited number of Input/output. It can
connect to any RTU or PLC through RS485, RS232 or CAN bus with the standard Modbus
communication protocol. Moreover, AMS-E3011 RIO can be used as a standalone device to
transmit numerous IO with twisted pair cable up to 3000ft (900m) farther. This product
benefit from a Cortex-M3 industrial-grade CPU, integrated power supply and a number of
accurate analog and digital inputs/outputs in order to data acquisition and perform
supervisory commands.

AMS-E3011 RIO User’s Manual
Technical Specification
Power Supply and Consumption
External Power
+9-36 VDC
*(18-75 VDC available as a request)
Power Consumption
1.5 W max
I/O
Digital Input
8 Ch (+15~30VDC) Isolation 2.5KV RMS
*(8 Ch (+40~55VDC) available as a request)
Digital Output
4 Ch (Relay 1A ~ 125VAC)
Analog Input
4 Ch 12Bit (4-20mA / 0-20mA / 0-5V)
Communication
Internal
RS485, RS232, CAN
Protocols
Modbus Master/Slave
Baud rate
600~921600 bps
(Easy online setup with DIP-Switches)
Slave ID
1-15
(Easy online setup with DIP-Switches)
Computer
CPU
32-bit ARM Cortex-M3
Real Time Clock
Internal RTC
Accuracy 5 sec in year @ 25’C
Physical
Size (WxHxD)
105x91x58.4 mm
4.13x3.58x2.3 inches
Material
ABS UL-94-HB
Mounting
DIN Rail mounting
Wall Mounting Available
Environmental Parameter
Temperature
-40°C ~ 80°C
EPIL Certified
Humidity
0 ~ 95 % non-condensing
Standards
EMC:
IEC61000-4-2
IEC61000-4-4
IEC61000-4-5
IEC61000-4-6
IEC61000-4-8
EPIL & AUT Certified

AMS-E3011 RIO User’s Manual
1.5. Hardware block diagram:
The following figure shows the AMS-E3011 block diagram with all features.
Figure 1, AMS-E3011 Block Diagram

AMS-E3011 RIO User’s Manual
1.6. Physical Dimensions

AMS-E3011 RIO User’s Manual
1.7. Appearance
The following figure depict AMS-R3011 RIO controller in the Isometric View.