ALZA DA-201QA User manual

GAS HEATER DA-201QA
USER MANUAL
FOR YOUR SAFETY PLEASE READ THIS MANUAL CAREFULLY AND OPERATE THE
APPLIANCE ACCORDING TO THESE INSTRUCTIONS. PLACE INSTRUCTIONS IN A SAFE
PLACE FOR FUTURE REFERENCE. ONLY USE IN A WELL VENTILATED AREA.

2
Dear customer,
Thank you for purchasing our product. Please read the following instructions carefully
before using for the first time and keep this user manual for future reference. Pay
particular attention to the safety instructions. If you have any questions or comments
about the device, please contact the customer line. Customer line, availability 24 hours a
day: 225 340 111, www.alza.cz.
Importer: Alza.cz a.s. Jankovcova 1522/53, Holešovice 170 00 Prague 7 www.alza.cz
•Use only in a well ventilated area.
•Do not use in leisure vehicles such as caravans and auto caravans.
•This appliance requires a hose and regulator, check with your gas supplier.
•Read the instructions before using this appliance.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A
FIRE OR EXPLOSION MAY RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY
OR LOSS OF LIFE.

3
WARNINGS
1. Never attempt to light if the hose appears loose or damaged in any way.
2. Do not press the ignition button for more than 40 seconds.
3. Never disconnect the regulator while cylinder valve or regulator is on.
4. Don't change cylinders in area which open fire exists.
5. Don't expose your cylinder to extreme heat.
6. Do not store any other cylinders in the room in which your heater is being used.
7. Do not insert your finger or any other material through the safeguard of the heater.
8. Leave at lease 1 meter distance between your heater and any other heat source.
9. Do not let unauthorized persons tamper with your heater.
10. Do not use appliance under electrical socket outlets.
11. Do not use the heater in bathrooms, showers of swimming pool, leisure vehicles
such as caravans or auto caravans.
12. This heater must not be used without a gas cylinder fitted for stability purposes.
13. Do not cover your heater. Fabrics, clothing, hangings, net curtains, bed lines and
other flammable materials may ignite if placed against the outlets of your heater.
14. In the event of a gas leak, the appliance must be switched off immediately, close the
valve on the gas cylinder and on the switch-on valve of the regulator. Disconnect the
regulator from the bottle.
15. Switch off the appliance at the regulator switch on the valve and the regulator after
use. Disconnect the gas bottle.
16. Only use in a well ventilated areas.
17. The protective screen of this appliance is intended to prevent the risk of fire or injury
due to burns and no part of it may be permanently removed. IT DOES NOT PROVIDE
EFFECTIVE PROTECTION FOR YOUNG CHILDREN OR OLD PERSONS.
18. Do not move the appliance when operating, shocks and bumps may activate the
safety device.
19. Do not use this heater with a programmer, timer, separate remote-control system or
any other device that switches the heater on automatically, since a fire risk exists if
the heater is covered or positioned incorrectly.
20. The fireguard of this heater is intended to prevent direct access to heating elements
and must be in place when the heater is in use. The fireguard does not give full
protection for young children and for infirm persons.
21. WARNING: In order to avoid overheating, do not cover the heater.
22. Children under the age of 3 should be kept out of reach unless they are under
constant supervision. Children must not connect, regulate and clean the appliance or
perform maintenance.

4
TECHNICAL CHARACTERISTICS
Type: Mobile Infrared Space Heater equipped with atmosphere sensing system and
flame failure Device.
Dimensions: 420*360*720mm( D*W*H )
Category: I3B/P(30)
Countries of Destination: CZ/SK/HU
Pressure: 30 mbar
Heater input: 1.5kW(Minimum), 2.9kW(Medium), 4.20kW(Maximum)
Consumption: 110g/h(Minimum), 207g/h(Medium), 305g/h(Maximum)
Regulator outlet pressure: 30 mbar
Power: 220-240V/50-60HZ
Electric input: 1.5kW
Injector size: 0.59mm
Ignition system: Piezo Electric
Cylinder Type: Up to 15.0kg cylinders at maximum diameter 32cm and height 62cm.(for
cabinet gas heater)

5
SAFETY PRECAUTIONS
1. Always use the heater in accordance
with the instructions supplied with each
heater. Keep the user manual in a safe
place.
2. DO NOT place clothes or other
material on the heater. This could cause
a fire risk or affect the efficiency of the
appliance.
3. DO NOT position heater close to
furniture.
4. DO NOT move heater from room to
room when lit.
5. DO NOT position heater close to walls,
furniture, net curtains, bed linen or any
flammable materials, as this could result
in a risk of fire. The following minimum
distances should be respected: 50cm
from the sides and 100cm from the
front. ALWAYS face the heater towards
the centre of the room. The heater
should be positioned on a level surface
at all times.
6. If a leak is suspected, DO NOT
disconnect the regulator. Check all
connections. Slowly turn the gas on and
brush the connections with soapy water,
or a leak detection spray. A gas leak will
form bubbles. If a leak is found, turn the
gas off. DO NOT use the heater again
until it has been checked by a
competent person in accordance with
the Gas Safety (installations and use)
Regulations 1998.

6
Note: Minimum distance from mobile heater to the ceiling at least 1000mm.
USING ENVIRONMENT
Your heater consumes oxygen while it is in use. For this reason, adequate ventilation
should be provided in rooms in which the heater is used. This ensures the removal of
products of combustion and allows the entry of replacement air.
Adequate ventilation should considerably reduce condensation occurring. The following
table shows the smallest sizes of rooms suitable for each heat setting and the
ventilation,which should be provided.
FOR INFRARED MODELS:
Number of Radiant
Continously IN USE
OTHER ROOM SIZE
LIVING ROOM SIZE
VENTILATION
Low
Level
High
Level
1
15 cubic meters –
1.5m×4m×2.5m
30 cubic meters –
2.8m×4m×2.5m
105cm2
105cm2
2
28 cubic meters –
2.8m×4m×2.5m
58 cubic meters –
5.2m×4m×2.5m
105cm2
105cm2
3
42 cubic meters –
4.2m×4m×2.5m
84 cubic meters –
8.4m×4m×2.5m
105cm2
105cm2

7
1. This appliance requires a hose and a regulator.
2. Only use in well ventilated areas.
3. Do not use in vehicles, caravans or auto caravans.
4. Do not attempt to use in high rise flats, basements, bathrooms or bedrooms.
5. This appliance should be tested for leaks before initial use and whenever the
cylinder is reconnected.
6. It is important that all gas connections have been correctly made to prevent any
leakage. Do not use a naked flame to test for leaks. Use soapy water or a leak
detection spray.
7. Always use your cylinder in an upright position.
8. Always turn off the appliance at the regulator when not in use.
9. When lighting your heater for the first time, or after a period of time has passed
since the last use, light the heater outside and burn outdoors for 15 minutes.
10. Do not use your heater while sleeping.
11. Do not use your heater in high-rise flats.
12. Do not use your heater in basements, bathrooms or bedrooms.
13. This appliance requires a hose and a regulator, check with your gas supplier for the
correct type according to the cylinder being used and any regulations at that time.
14. The guard on the appliance is to prevent risk of fire or injury from burns and no part
of it should be permanently removed. It does not give full protection to young
children or the infirm. We would recommend a fireguard BS 8423 to be fitted.
Use only regulator and hose approved for LP Gas at the correct pressures.
The pressure adjuster should comply with the standard ČSN EN 16129 and current
regulations in the country where it is installed, which may be found at your nearest
retailer of gas items refer to the technical data. It is strictly prohibited to use adjustable
pressure.
The life expectancy of the regulator is estimated at 10 years. It is recommended that the
regulator is changed within the 10 year of the date of manufacture or changed
according to the national regulations.
The hose used must conform to the relevant standard for the country of use.The length
of the hose must be 0.5m (maximum). Worn or damaged hose must be replaced. Ensure
that the hose is not obstructed, kinked, or in contact with any part of the appliance other
than at its connection. It is recommended that the hose is changed within 1 year of the
date of manufacture or the national conditions require it.

8
HOW TO CHOOSE THE PROPER REGULATOR
30 mbar regulator with butane,propane or their mixtures @ category I3B/P(30)
WARNING
Perform a leak test on all connections every time you reconnect the cylinder, or if the
heater has not been used for a significant period.
Do not twist the flexible tube or the hose.
Do not move the appliance when lit.

9
FAULT FINDING CHART:
SYMPTOMS
FAULT
REMEDY
1. Pilot will not light
automatically.
No spark across electrode
gap.
A) Ensure that piezo-
electric switch is
functioning correctly.
B) Check that electrical
lead is not damaged.
2. Pilot will not light
automatically but points
(A) to (E) are satisfactor any
the pilot will light with a
match.
Incorrect position of spark
in relation to pilot gas flow.
Re-position spark plug so
that spark jumps across
gap flow.
3. Heater will not remain
alight when pressure is
released from ignition
button.
Electro-magnetic valve
closes while heater is
alight.
A) Ensure that
thermocouple probe is
located in pilot flame.
B) Ensure good connection
between thermocouple
and valve.
C) Check thermocouple.
D) Check electromagnetic
value.
4. After changing to
maximum position with all
three plaques alight one or
more plaques appear
below normal intensivity.
A) Blocked jets.
B) Partially blecked supply
tube.
A) Remove and clean
blocked jet.
B) Remove supply tube,
remove jets and blow
through the tube.
5. Difficulty in cross lighting
from position 1 to position
2 or 3.
A) Air draught directed
away from a first plaque.
B) Position of the pilot
flame.
A) Charge the location of
the appliane so that it is
not adversely affected by
air draught.
B) Position pilot so that it
impinges across bottom
corner of 2nd plaque as
well as 1st plaque.
6. Smell of combustion.
Missing piece of ceramic
fireclay.
Inspect perimeter of each
plaque and locate place
where some fireclay has
been displaced.
Repair with PYRUMA and
leave to sot for
approximately 24 hours.
REPAIRS ARE TO BE CONDUCTED BY AUTHORIZED PERSONNEL ONLY.

10
CONNECTING THE CYLINDER
1. Place the gas filled cylinder into the back of the heater.
2. Clip on the gas regulator to the gas cylinder, connect the flexible tubing to regulator
and gas valve.
3. Turn the cylinder and the regulator on.
4. If the regulator is not supplied or is missing, please contact your gas supplier to
advise of the correct type for the gas cylinder being used.
5. IMPORTANT TEST FOR LEAKAGE: This must be carried out in a well ventilated area,
free from naked flames and any other sources of ignition. With the regulator
connected to the cylinder, turn on the regulator control. Brush all connections from
gas cylinder to the valve of appliance, with a solution of detergent and water or a
leak detection spray. A stream of bubbles forming indicates a leak. If a leak is found
turn off at the regulator and disconnect the regulator from the bottle and remove
the gas cylinder outdoors or to a well ventilated area. DO NOT USE THE HEATER.
Contact your gas supplier for assistance. Fix the rear cover after leakage test.
HOW TO CHANGE A CYLINDER
1. Turn off at the regulator and allow the heater to cool fully before removing and
replacing the cylinder. Do not attempt to replace the cylinder whilst the heater is still
in use.
2. Cylinders must be replaced in a flame free environment.
3. Do not smoke while changing the cylinder.
4. When you need to replace your empty cylinder, turn the gas off at the valve or
regulator and take the empty cylinder out of the heater.
5. Remove the regulator from the empty cylinder.
6. Follow the steps described under “CONNECTING THE CYLINDER“, connect a new
cylinder.
Table of contents
Languages:
Other ALZA Gas Heater manuals
Popular Gas Heater manuals by other brands

Superior
Superior BGE18NV Installation and operation instructions

Dru
Dru Room-sealed atmospheric gas-fired heating... user manual

klover
klover TKR 35 user guide

Rothenberger Industrial
Rothenberger Industrial 035984 instruction manual

New Buck Corporation
New Buck Corporation 34 user manual

Hargrove
Hargrove Timberland Glow Operation and installation guide

Superior
Superior BGE18NR Operation instructions

Brant Radiant Heaters
Brant Radiant Heaters QTD Series User instruction

L.B. White
L.B. White Therma Grow HW220 Owner's manual and instructions

Sealey
Sealey LP35.V5 instructions

Italkero
Italkero Falo Evo User manual and assembly instructions

Desa
Desa 30LP owner's manual








