Option 2: 802.3af-Compliant PoE Switch
1. Connect the CX200 Ethernet port to an 802.3af-compliant PoE switch with
an Ethernet Cable.
2. Connect a computer to the switch.
3. Make sure the Power LED turns into a solid light for AP configuration.
Factory Reset
Besides the software-based reset via AP WebUI, there are the two options to
restore the CX200 to factory default settings.
Option 1: Using Reset Button of PoE Injector
1. Power up the CX200 with the PoE injector as
illustrated in the power option #1 above.
2. Locate the Reset Pin Hole on the injector.
3. Insert a sharp-pointed object, e.g. paper clip,
into the hole and press for 10-20 seconds.
Option 2: Using AP Factory-Reset Tool
For details, please visit https://www.altaitechnologies.com/tools-and-
utilities/