Safety Notes
DEHUMIDIFIERS
• The Storm Elite dehumidifier must always be connected using a grounded electrical
connection as required for all electrical appliances. The warranty is voided and all respon-
sibility for the operation transfers to the owner if non-grounded wiring is utilized.
• Your Storm Series dehumidifier must be maintained and serviced by qualified technicians.
• Storm dehumidifiers are intended for use only when the unit is installed in a level and
upright position. Operating the unit in any other position could cause water to come in
contact with the electrical components.
• Before moving the dehumidifier, turn off the unit and allow the pump reservoir to empty (if
unit is already off, press “P” button to confirm drain reservoir is empty). After the pump has
finished operation, unplug the power cord and relocate the unit to the desired position.
• If the inside of the machine has gotten wet for any reason, the unit should be opened and
allowed to dry thoroughly before reconnecting it to electric and restarting.
• For proper operation, neither the inlet or discharge should be positioned against a wall. A
minimum of 8” clearance between the Storm and any obstruction is required.
• Do not insert any objects or fingers into the inlet or discharge.
• All work on the machine should be done with the unit off and unplugged.
• Do not spray water or cleaner directly on the exterior of the Elite. Only use a damp cloth
to clean the exterior and always unplug the unit first.
• Do not use unit as shelf or device to hang clothes as this could cause damage to unit.
• Do not stand on the machine.
※

※Table of Contents
DEHUMIDIFIERS
Introduction..................................................................................................01
Unit Overview...............................................................................................03
Operating Instructions..................................................................................04
Preparing the Unit for Use............................................................................09
Maintenance & Repair..................................................................................11
Storing Your Dehumidifier.........................................................................................15
Troubleshooting............................................................................................15
Warranty.......................................................................................................17
Readiness Checklist.....................................................................................19
Service Checlist............................................................................................20
※

DEHUMIDIFIERS
※Introduction
Identification
-1 -
Congratulations on purchasing a Storm Elite dehumidifier! The Storm Elite comes
with an extensive warranty plan. To ensure you are eligible, be sure to note the serial
number and date of purchase. The serial number can be found on the data on the
back of the unit.
Model Name: Storm Elite
Serial Number:__________
Date of Purchase: ___________
Customer Service
• Contact your installing contractor
• Contact Seaira Global: 910-660-0962
※
• 125 Pints Per Day
• High COP: 2.4 L/kWh
• Only 63 dBa
• Automatic humidistat
• Built-in Pump with Overflow Protection
• Self Monitoring System
• Eco Friendly R410A Refrigerant
• Easy Access to Internal Components
• Auto Restart After a Power Outage
• Unit Can Be Ducted, If Necessary
Features
For additional questions concerning the operation fo your dehumidifier, please

How Your Storm Dehumidifier Works
Installation
120 Volts may cause serious injury from electric shock.
WARNING
WARNING
DEHUMIDIFIERS
-2 -
The Storm Elite dehumidifier utilizes its integral humidistat to monitor the conditioned space.
Once conditions are outside the desired setpoint, the compressor energizes and air is
drawn across an evaporator coil. The evaporator coil is cooler than the dew point of the air
so water vapor will turns into liquid condensation. The air is then reheated through the
condenser coil and distributed back into the room.
1. Disconnect electrical power before servicing
2. Only plug unit into grounded electrical outlet
3. Do not use an extension cord
4. Do not use a plug adapter
Power Supply: 115V, 60 Hz AC Only 1 Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp Time Delay Fuse or Circuit Breaker
Place the Elite in your desired location. The inlet of the machine should be at least 8”
from any obstructions. If the unit has been transported in a horizontal position, allow it to
sit in an upright position for at least 30 minutes before operating.
Do not use dehumidifier in an environment where corrosive or high VOC materials are applied.
Electrical Supply

Front View
Rear View
Handle
Wheel
Front Cover
Air Outlet
Access Latch
Control Panel
Power Cord
Tubing &
Cord Rack
Drain Tube
Connection
Air Intake
Air Filter
DEHUMIDIFIERS
-3 -
※
Unit Overview
※

-4 -
Operating Instructions
Control Panel Overview
OK
M
P
Menu
Up Button Down Button LCD Monitor
On/Off
Select/OK Drain Pump
P
M
DEHUMIDIFIERS
Press the on/off button once to power the dehumidifier on and begin operation. Once it is
powered on, the display will show room humidity levels unless another button is being
pressed. To power off the unit, press the on/off button one time.
NOTE: When the unit is turned off, the fan will run for 1 minute prior to shutting off. In addition, the
condensate pump will pump for approximately 15 seconds to drain the reservoir.
Press the pump button once to remove any water from the integral pump’s reservoir. This is
useful if you need to move the dehumidifier or plan on storing it for an extended period of time.
1. On/Off Button
2. Pump Button
3. Menu Button
Pressing the Menu button gives you the capabilitiy to access the settings. Continue pressing
the Menu button until your desired selection is flashing. Press the (OK) key to confirm that selection
and you will move to a submenu.
After you’ve completed your task, select “R” (return), then press the (OK) button to move back to the
previous menu. Alternatively, you can wait 10 seconds and you will automatically return to the main
screen.
From the main menu you can access:
• Humidity Settings: Adjust the humidity setpoint
• Timer Settings: Set up auto start time, auto stop time, and time cycles
• Temperature Scale Settings: Choose between Celsius and Fahrenheit for temperature
readings
NOTE: See “How to Change the Settings” for detailed programming instructions
※
※

-5 -
poweron
n
UnitO
OK
Inlet32℃76%
DEHUMIDIFIERS
Use this button to confirm a selection.
The up and down buttons are used to adjust the humidity or timer settings..
Please note that the LCD monitor will go blank if no buttons are pushed. Push any
button to activate the display.
• The display will Show “Power On” when the machine has been plugged in but not
started.
• The display will show “Unit On” when the machine is running. This display will
change after 2 seconds.
4. Select/OK Button
5. Up Button Down Button
6. LCD Display
Understanding the Display Screen
• The LCD interface shows two lines of data. The first line will display the room
temperature and humidity.
or
Job.T000
5
Humi.set50%
• The second line will alternate between showing the working time (Job T) and
Humidity Setpoint.
NOTE: The second line will change every ten seconds.
2. Display During Operation
1. Display WhileTurning on the Dehumidifier

Inlet32℃76%
Draining
Inlet32℃76%
Dig
ft
en
ros
ff
UnitO
Draining
Job.T000
5
089L fe
i.0H
or
DEHUMIDIFIERS
• When you press the “power off” button, two lines of data will be displayed. The top line will
read “Unit Off”. The bottom line will read “Draining” while the pump is being emptied
(approximately 15 seconds).
• Once the pump reservoir has drained, the contents of the second line will alternatively
show “job hours” and “total hours”, switching every 10 seconds until the one minute final
fan cycle is completed.
• When you press the “P” button to drain the pump, the second line of the display screen
will show draining. Draining will also appear during automatic draining while the dehumidi-
fier is operating.
• The display will show “defrosting” when the machine is in defrosting mode. If both “De-
frosting” and “Draining” are occuring simultaneously, “Defrosting” will show on the screen.
• When one of the timing settings is being used (auto start, auto stop, or timing cycle), that
information will show on the second line of the display
4. Display While Turning off the Dehumidifier
3. Display During Draining and Defrosting
5. Display While Using Timers
TimeOn00 05
TimeO000
5
ff
O000000
I11
Time Remaining Until Auto Start
Time Remaining Until Auto Stop
Time Remaining Until Cycle Starts
-6-

-7-
HumidTimer
TempUR
Humid
R
Setting
35%
DEHUMIDIFIERS
c. Press the menu key until the humidity level (bottom left of display) is flashing. It
will either say “Co” for continuous operation or a number for a specific percentage.
2. Timer Settings (Timer)
This selection allows you to set a timer for the unit to turn on or turn off. You can also set up
cycle timing, which lets you set up a repeating cycle of specific on and off durations.
b. Press the (M) button until “Humid” is flashing. Press (OK) to select this option.
The screen will show:
a. Press the Menu (M) button. The screen will show:
1. Setting the Humidity Level (Humid)
NOTE: As long as the machine is plugged into power, the settings can be changed. The unit does
not have to be operating to modify the setup.
How to Change the Settings
d. Use the Up or Down arrows to set the machine to your desired level. Press the
(ok) button when finished. The cursor will automatically move to the “R”, which will
be flashing. Press (ok) to confirm moving to the previous menu or wait 10 seconds
and you will automatically return to the main menu.
a. Press the menu key several times until the Timer button is flashing. Press the (ok)
button to confirm.
HumidTimer
TempUR
b. The screen will show: To.on, T.off, T.I/0, R
ff
noo
T
T
T
R
/
.
..
I0
Other manuals for Storm Elite
1
Table of contents
Other ALORAIR Dehumidifier manuals

ALORAIR
ALORAIR Sentinel SLGR 1400X User manual

ALORAIR
ALORAIR Storm SLGR 850C User manual

ALORAIR
ALORAIR Sentinel HDi120 User manual

ALORAIR
ALORAIR ARMORED 170L User manual

ALORAIR
ALORAIR STORM PRO User manual

ALORAIR
ALORAIR Sentinel HDi120 User manual

ALORAIR
ALORAIR STORM PRO User manual

ALORAIR
ALORAIR Storm LGR Extreme User manual

ALORAIR
ALORAIR Sentinel HD90 User manual

ALORAIR
ALORAIR Sentinel HDi100 User manual