Alfalaval 8692 User manual

Quickstart
English Deutsch Français
Type 8692 / 8693
Positioner / Process Controller
Positioner / Prozessregler
Positionneur / Régulateur de process
ESE02210EN/DE/FR

We reserve the right to make technical changes without notice.
Technische Änderungen vorbehalten.
Sous réserve de modifications techniques.
© 2011 - 2012 Alfa Laval A/S
Quickstart 1202/01_EU-ML_00809647 / Original DE

3
Type 8692, 8693
1. QUICKSTART .....................................................................................................5
1.1. Symbols .............................................................................................. 5
2. AUTHORIZED USE .........................................................................................6
2.1. Restrictions ........................................................................................ 6
2.2. Predictable misuse ..........................................................................6
3. BASIC SAFETY INSTRUCTIONS .............................................................7
4. GENERAL INFORMATION ...........................................................................8
4.1. Contact address ...............................................................................8
4.2. Warranty ............................................................................................. 8
5. DESCRIPTION OF SYSTEM .......................................................................9
5.1. Functions ..........................................................................................10
6. TECHNICAL DATA ........................................................................................10
6.1. Conformity .......................................................................................10
6.2. Standards .........................................................................................10
6.3. Operating conditions .....................................................................10
6.4. Mechanical data .............................................................................11
6.5. Type label ........................................................................................11
6.6. Pneumatic data ...............................................................................11
6.7. Electrical data..................................................................................12
7. CONTROL AND DISPLAY ELEMENTS ...............................................13
7.1. Function of the keys ........................................................................ 13
7.2. Operating state ................................................................................ 14
7.3. Operating levels ............................................................................... 14
7.4. Display in operating state AUTOMATIC .................................... 15
8. INSTALLATION ...............................................................................................15
8.1. Safety instructions .........................................................................15
8.2. Installing the positioner / process controller
on process valves belonging to series 2103 and 23xx .........16
8.3. Installing the positioner / process controller
on process valves belonging to series 26xx and 27xx ............. 17
9. FLUID INSTALLATION ................................................................................19
9.1. Safety instructions .........................................................................19
9.2. Installing the process valve ..........................................................19
9.3. Pneumatic connection of the positioner /
process controller ..........................................................................19
10. ELECTRICAL INSTALLATION ...............................................................21
10.1. Safety instructions .......................................................................21
10.2. Electrical installation 24 V DC ..................................................21
10.3. Electrical installation PROFIBUS DP ......................................27
10.4. Electrical installation DeviceNet ...............................................29
Positioner Type 8692 and process controller Type 8693
english

4
Type 8692, 8693
11. START-UP TYPE 8692 ............................................................................. 31
11.1. Safety instructions .......................................................................31
11.2. Specifying the basic settings ....................................................32
11.3. Automatic adjustment X.TUNE ...............................................34
12. START-UP TYPE 8693 ............................................................................35
13. ACCESSORIES ...........................................................................................35
14. SAFETY POSITIONS ...............................................................................36
15. PACKAGING, TRANSPORT, STORAGE ..........................................37
english

5
Quickstart
Type 8692, 8693
1. QUICKSTART
The operating instructions describe the entire life cycle of the device.
Keep these instructions in a location which is easily accessible to
every user and make these instructions available to every new owner
of the device.
Important Safety Information!
Read Quickstart carefully and thoroughly. Study in particular the
chapters entitled “Basic safety instructions” and “Authorized use”.
• Quickstart must be read and understood.
Quickstart explains, for example, how to install and start-up the
device.
A detailed description of the device can be found in the operating
instructions for positioner Type 8692 and Type 8693.
1.1. Symbols
The following symbols are used in these instructions.
DANGER!
Warns of an immediate danger!
• Failure to observe the warning may result in a fatal or serious
injury.
WARNING!
Warns of a potentially dangerous situation!
• Failure to observe the warning may result in serious injuries or
death.
CAUTION!
Warns of a possible danger!
• Failure to observe this warning may result in a medium or minor
injury.
NOTE!
Warns of damage to property!
indicates important additional information, tips and
recommendations.
refers to information in these operating instructions or in
other documentation.
designates a procedure that must be carried out.
english

6
Authorized use
Type 8692, 8693
2. AUTHORIZED USE
Non-authorized use of the positioner Type 8692 and the
process controller Type 8693 may be a hazard to people,
nearby equipment and the environment.
• The device is designed to be mounted on pneumatic actuators
of process valves for the control of media.
• Do not expose the device to direct sunlight.
• Use according to the authorized data, operating conditions and
conditions of use specified in the contract documents and oper-
ating instructions. These are described in the chapter entitled
“6. Technical data”.
• The device may be used only in conjunction with third-party
devices and components recommended and authorized by Alfa
Laval.
• In view of the large number of options for use, before installa-
tion, it is essential to study and if necessary to test whether the
positioner is suitable for the actual use planned.
• Correct transportation, correct storage and installation and
careful use and maintenance are essential for reliable and fault-
less operation.
• Use the positioner Type 8692 and 8693 only as intended.
2.1. Restrictions
If exporting the system/device, observe any existing restrictions.
2.2. Predictable misuse
• Do not feed any aggressive or flammable media into the pilot air port.
• Do not feed any liquids into the pilot air port.
• Do not put any loads on the body (e.g. by placing objects on it or
standing on it).
• Do not make any external modifications to the device bodies. Do not
paint the body parts or screws.
english

7
Basic safety instructions
Type 8692, 8693
3. BASIC SAFETY INSTRUCTIONS
These safety instructions do not make allowance for any
• contingencies and events which may arise during the installation,
operation and maintenance of the devices.
• local safety regulations – the operator is responsible for observing
these regulations, also with reference to the installation personnel.
Danger – high pressure!
• Before dismounting pneumatic lines and valves, turn off the
pressure and vent the lines.
Risk of electric shock!
• Before reaching into the device or the equipment, switch off the
power supply and secure to prevent reactivation!
• Observe applicable accident prevention and safety regulations
for electrical equipment!
General hazardous situations.
To prevent injury, ensure:
• Installation and repair work may be carried out by authorized
technicians only and with the appropriate tools.
• After an interruption in the power supply or pneumatic supply,
ensure that the process is restarted in a defined or controlled
manner.
• The device may be operated only when in perfect condition and
in consideration of the operating instructions.
• The general rules of technology apply to application planning
and operation of the device.
NOTE!
Electrostatic sensitive components / modules!
The device contains electronic components which react sensitively
to electrostatic discharge (ESD). Contact with electrostatically
charged persons or objects is hazardous to these components. In
the worst case scenario, they will be destroyed immediately or will
fail after start-up.
• Observe the requirements in accordance with EN 61340-5-1
and 5-2 to minimize or avoid the possibility of damage caused by
sudden electrostatic discharge!
• Also ensure that you do not touch electronic components when
the supply voltage is present!
english

8
General information
Type 8692, 8693
The positioner Type 8692 and the process controller Type
8693 were developed with due consideration given to the
accepted safety rules and is state-of-the-art. Nevertheless,
dangerous situations may occur.
Failure to observe this operating manual and its operating instructions
as well as unauthorized tampering with the device release us from
any liability and also invalidate the warranty covering the devices
and accessories!
4. GENERAL INFORMATION
4.1. Contact address
Contact your local Alfa Laval Company.
4.2. Warranty
The warranty is only valid if the positioner Type 8692 and the process
controller Type 8693 is used as intended in accordance with the
specified application conditions.
english

9
Description of system
Type 8692, 8693
5. DESCRIPTION OF SYSTEM
Positioner or process controller
Actuator
Valve body
Process valve
Fig. 1: Structure 1
The positioner Type 8692 and the process controller Type 8693 are
electropneumatic positioner controllers for pneumatically actuated
control valves with single-action or double-action actuators.
The positioner, together with the pneumatic actuator, make up an
optical and functional unit.
The control valve systems can be used for a wide range of control
tasks in fluid technology and, depending on the application condi-
tions, different process valves from the Alfa Laval range can be
combined with the positioner or with the process controller. Slanted
seat valves, straight seat control valves, diaphragm or ball valves are
suitable.
Pilot air port
(label: 1)
Exhaust air port
(label: 3)
Electrical connection module
Transparent cap under it
control module with display and keys
Body casing
Additional exhaust air port (label: 3.1)
only for Type 23xx and 2103 with pilot-operated control
system for high air output (actuator size ø 125 / 130)
Air intake filter
Pressure limiting valve
Fig. 2: Structure 2
english

10
Technical data
Type 8692, 8693
5.1. Functions
Type 8692 - Position controller
The position of the actuator (stroke) is regulated according to the
position set-point value. The position set-point value can be spec-
ified by an external unit signal (or via field bus).
Type 8693 - Process controller
The process controller is integrated into a control loop. The stroke
of the valve is calculated from the process set-point value and the
process actual value via the control parameters (PID controller). The
process set-point value can be set by an external signal.
6. TECHNICAL DATA
6.1. Conformity
In accordance with the EC Declaration of conformity, the positioner
Type 8692 and the process controller Type 8693 are compliant with
the EC Directives.
6.2. Standards
Conformity with the EC Directives is verified by the following standards.
EN 61000-6-3, EN 61000-6-2, EN 61010-1
6.3. Operating conditions
WARNING!
Solar radiation and temperature fluctuations may cause mal-
functions or leaks.
• If the device is used outdoors, do not expose it unprotected to
the weather conditions.
• Ensure that the permitted ambient temperature does not exceed
the maximum value or drop below the minimum value.
Ambient temperature 0 – +55 °C
Protection class IP65 / IP67 according to EN 60529
(only if cables, plugs and sockets have
been connected correctly
and in compliance with the exhaust air
concept in chapter “9.3. Pneumatic
connection of the positioner / process
controller”).
english
This manual suits for next models
1
Table of contents
Languages:
Popular Valve Positioner manuals by other brands

Parker
Parker MX80L series product manual

Westlock
Westlock Quantum 2800 Installation & operating instructions

Samson
Samson 3730-0 Mounting and operating instructions

Samson
Samson TROVIS 3730-3 Mounting and operating instructions

ESCO Technologies
ESCO Technologies ETS LINDGREN 2302-001 user manual

SMC Networks
SMC Networks IP8000 manual

Samson
Samson FOUNDATION 3730-5 Mounting and operating instructions

Samson
Samson TROVIS SAFE 3731-3 Mounting and operating instructions

Flowserve
Flowserve Logix 3400MD User instructions

halstrup-walcher
halstrup-walcher HIPERDRIVE instruction manual

ABB
ABB TZIDC Commissioning instructions

Samson
Samson FOUNDATION 3730-5 Mounting and operating instructions