Alcolock ALCOLOCK GR User manual

Instruction manual
ALCOLOCK GR
ALCOHOL INTERLOCK
wireless
TM

Federal Communications Commission (FCC) Disclaimer
Changes or modications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
To comply with Radio Frequency (RF) exposure requirements, a separation distance
of at least 20 cm must be maintained between the antenna(s) of the Electronic Control
Unit (ECU) and all persons.
This device complies with Part 15 of the FCC rules. Operations are subject to the
following 2 conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that
may cause undesired operations
Industry Canada
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes:
1. L’appareil ne doit pas produire de brouillage, et
2. L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.

Alcohol Countermeasure Systems Corp
60 International Boulevard
Toronto, Ontario M9W 6J2 CANADA
T +1 416 619 3500
F +1 416 619 3501
acs-corp.com
For service inquiries and the toll free number, refer to the Compliance Guide.
ACS, ALCOHOL COUNTERMEASURE SYSTEMS, ALCOLOCK and the “Molly”
are trademarks of Alcohol Countermeasure Systems (International) Inc. and are
used under license. Alcohol Countermeasure Systems is the trading style of Alcohol
Countermeasure Systems (International) Inc.
© 2011 - 2014 Alcohol Countermeasure Systems
The information disclosed in this document is the valuable property of Alcohol
Countermeasure Systems Corp. and all copyright and other proprietary rights to this
document are reserved. No reproduction of this document is permitted without the
prior written consent of Alcohol Countermeasure Systems Corp.


Indicator light
Display
Air vent
SIDE VIEWFRONT VIEW
ALCOLOCK GR DIAGRAM
USB port
The navigation button permits the selection of
options shown on the display.
Press Left, Right, Up, Down or Centre (Enter) on
the navigation button to select options, based on the
location on the display.
Mouthpiece
Navigation
button
Mouthpiece port

TABLE OF CONTENTS
Safety and precautions ........................................................1
Product prole ......................................................................2
Getting started ......................................................................3
Alcohol inuence on testing ..........................................3
Terms used in this manual ............................................3
Display icons .................................................................3
Fees ..............................................................................4
Installation .....................................................................4
Maintenance ..................................................................4
Operating temperature ..................................................4
Battery voltage and unit charging ..................................4
Handset sleep mode .....................................................5
Assistance .....................................................................5
Inserting the mouthpiece .....................................................5
Using the ALCOLOCK GR ...................................................6
Performing a test ...........................................................6
Results displayed ..........................................................7
Warm-up and standby (where applicable) .....................8
Restart without breath test ............................................8
Performing retests .........................................................9

Menu options ......................................................................11
Power down ................................................................11
Dates ...........................................................................11
Reset ...........................................................................12
Service ........................................................................12
Maintenance and troubleshooting ....................................13
Troubleshooting table ..................................................13
Service dates ..............................................................13
Service due ........................................................14
Service lockout ...................................................14
Error messages ..................................................15
Technical specications ....................................................17
Reset codes ................................................................17
Emergency override (where applicable) ......................17
Dealer service .............................................................17
Disposal of unit at end of service life ...........................17
Replacement parts ......................................................17
Service Record ...................................................................18
Index ....................................................................................19

ALCOLOCK GR1
SAFETY AND PRECAUTIONS
ALCOLOCK GR series of alcohol interlocks have been
designed for easy and safe operation. The device is to be
used only for the purposes specied herein. To help ensure
your safety, you must follow these precautions:
• Always use a clean mouthpiece for good hygiene and
to trap any foreign matter or excess moisture from the
breath sample
• Do not store mouthpieces in a cold area before use. This
will cause condensation to form in the mouthpiece and
droplets may enter the handset during the test
• Do NOT perform a breath test while the vehicle is in
motion. Complete a successful breath test before you
resume driving
• Do not eat, drink or smoke for at least 15 minutes
before the test. This could contaminate the breath
sample. Swish and swallow fresh water to remove any
contaminants from the mouth
• Avoid exposing the handset to direct sunlight for
extended periods of time
• If liquid spills onto the handset, remove with a cloth and
allow the handset to dry thoroughly. If there is substantial
moisture damage, do not activate the handset. Contact
your local service centre
• Keep all radio frequency transmitting devices
(such as mobile phones or laptops) away from
the ALCOLOCK GR unit to minimize interference,
particularly when performing a test
NOTE: The alcohol interlock WILL NOT shut your vehicle
off during operation.

INSTRUCTION MANUAL 2
PRODUCT PROFILE
ALCOLOCK GR series alcohol interlocks control the
normal operation of a vehicle through connections with the
power, starting and control systems. To start the vehicle,
the driver must provide a proper sample of breath with an
alcohol concentration (BrAC) below the preset limit. During
the operation of a vehicle, the driver will need to provide
additional breath samples to ensure continued compliance
with program requirements. The ALCOLOCK GR alcohol
interlock will not cause the vehicle motor to stop.
ALCOLOCK GR units consist of a handset that is the
link to the driver and an Electronic Control Unit (ECU) for
connection with the vehicle.
The ALCOLOCK GR handset may have a wired or wireless
connection to the ECU, depending on the version.
ALCOLOCK GR units are used in alcohol interlock programs
under the direction of a jurisdictional authority and are fully
compliant with international regulations for alcohol interlocks
being used in compliance programs.
WARNING!
• Do not open any enclosures. Doing so will
potentially damage the components within and void
the warranty
• Do not attempt to tamper with the installation or
circumvent the alcohol interlock. This is considered
a program violation
• Do not attempt to drive after consuming alcohol.
This is an unsafe practice and is considered a
program violation
• The ALCOLOCK GR device may engage a service
lockout if:
a. The scheduled service date is past due
b. An early/immediate recall has been triggered
and the device has not been serviced prior to the
lockout date indicated on the handset

ALCOLOCK GR3
GETTING STARTED
ALCOHOL INFLUENCE ON TESTING
WARNING! Drinking alcohol and eating foods containing
alcohol may cause a failed alcohol test.
Some factors that may affect the results of a test (because
of possible residual alcohol in the mouth) are consumption
of medicines, drops, gum, smoking and using mouthwash or
mouth spray. Rinsing the mouth with water and swallowing
after consumption of these products will remove possible
alcohol contamination.
Do not eat, smoke or drink for at least 15 minutes before
taking a test. Also, before taking a test, refrain from using
windshield washer uid for at least 10 minutes or using any
aerosol air fresheners, disinfectants, cologne, or perfume in
the vehicle, as these can also contain alcohol.
NOTE: The above list of factors that may affect the
results of a breath test is not exhaustive. There are
additional items that also may affect the results. Follow
this guide carefully to avoid incorrect results and consult
the service centre.
TERMS USED IN THIS MANUAL
• BrAC = Breath Alcohol Concentration
• BAC = Blood Alcohol Concentration
• Preset Limit = Set according to local regulations
• ECU = Electronic Control Unit
DISPLAY ICONS
The handset is in communication with the ECU.
There is no communication between the handset
and the ECU.
The power indicator is illuminated by 5 power
bars. Charge the handset if only 1 power bar
remains.
Table of contents