Airofog U260 User manual

Airofog professional
Cold Fogger Manual
U240/ U110
U260/ U120

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Safety
Measurements
• Do not make any modications or repairs to the Cold Fogger by yourself
• Wear personal protective equipment (PPE) when handling dangerous substances
• Keep instructions manual; if Cold Fogger is transfered to a new owner give them the manual too
• Before use, operators must be aware of all protection and safety measures.
• It is recommended to wear ear protection against noise.
• Adhere to chemical suppliers instructions regarding solution concentration and protective measures.
• Wear a protective mask when fogging with dangerous chemicals and/or air suspended particles.
• When fogging, use protective equipment, proper respiratory protection, protective gloves as
applicable.
• Store the appliance in a dry place, far from heat sources.
• Unplug the appliance when it is not in use.
• Keep the appliance out of the reach of children and the person who is not aware of dangers.
• To avoid danger of re or explosion, do not fog with ammable liquid, especially in enclosed areas.
• Do not fog near naked ames.
• Never use the appliance with wet hands or feet or with bare feet.
• Protect the power cord away from heat, oil, sharp edges and rough surfaces.
• Do not force or change the moulded plug in any way.
• Do not use a cord that is cut or frayed, otherwise it is dangerous.
• Use the appliance only for the purpose it was designed for.
• Never leave the appliance unattended while it is operating.
• Avoid breathing fog output and make sure that the air breathed-in by the motor is as dry as
possible.
• Never carry out maintenance service work if the appliance is connected to a power socket.
• Only service by qualied skilled personnel who are allowed to work with the appliance.
• Make sure that the voltage indicated or the socket is as the same as that of the motor.
• Operate in a well ventilated area.
• Use eye protection and face mask when using this equipmenet.
Airofog ULV Cold Fogger systems referred to in this
document are designed for use by qualied and
experienced personnel. Please read this instruction
thoroughly before usage.
Safety Measurements

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Specications
It is the operator’s responsibility to ensure the safe use of the fogger and
that they’re fully compliant with national or local regulations governing
compression sprayer and applications of pesticides.
AIROFOG USA is not liable for damages that has ocurred due to improper
use/repair/maintenance, the use of non-recommended or non OEM parts,
and acceptance of damaged/broken sprayers for any reason.
Caution
U260 (220 - 240 V) / U120 (110 -120 V)
U240 (220 - 240 V) / U110 (110 - 120V)
220 - 240 V, 50 / 60 Hz, 800 W
110 - 120 V, 50 / 60 Hz, 700 W
1 gallon, side opening for relling polyethylene, UV-light resistant
U260/U120 appro. 40-400 ml/min.
U240/U110 appro. 25-150 ml/min.
5-positition liquid dosage control
U260/U120 appro. 0-260 ml/min
double woven, 2 inches wide
extension hose 20 inches for U260
U260/U120: 7.5 lbs; U240/U110: 6.8 lbs.
U260/U120: 9.7 lbs; U240/U110: 9 lbs.
Ø 11 x H16 in
L36 x W32 x H44 cm
Model:
Electric Motor:
Solution Tank:
Output:
Optional:
Shoulder Strap:
Standard Accessory:
Net Weight:
Gross Weight:
Fogger Dimensions:
Packing Dimensions
Specications

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Main
Features
• Airofog ULV cold fogger
operates effectively according
to ultra low volume (ULV)
method. A powerful electric
motor distributes the ne
droplets evenly over the
affected area. The droplets
remain airborne for a sufcient
time. The needle dosage
control knob allows a liquid
volume control, depending on
the viscosity level of the liquid
to be fogged.
Features
32
4
5
1
model: U260/U120
Airofog USA guarantees the ULV Cold Fogger System to be free of defects in materials and workmanship to the
original purchaser for a period of one(1) year on labor and parts which are not subject to usual wear
During this period, AIROFOG USA will replace and/or repair the parts and manufacturer faults on the exclusive
judgment of our technical department free of charge
Shipping and dispatch of defect equipment will be at original purchaser’s expense
Guarantee does not cover damages occurred during transport or by incorrect handling, tampering, use, or the
use of non-recommended products and so on.
Under no circumstances will AIROFOG USA be liable for damages due to improper use or application.
Under no circumstances will AIROFOG USA be responsible for damages to any persons or property.
Airofog Guarantee
On/off switch
Flow control regulator knob
Power cord
Closure ring
Solution tank
1.
2.
3.
4.
5.

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Care &
Maintenance
29
20 U240 / U110
Periodically clean the liquid lter (20) and
the PP lter (29 & 29/1). Remove the lter
and rinse it with running water to remove
the clinging particles.
Avoid contamination when changing
chemicals by running the fogger with clean
water (or appropriate solvent) through unit
and rinse tank thoroughly.
Periodically check the cleanliness of the air
lter (11). If the motor does not breathe a
sufcient quantity of clean air, the fogging
operation will be inefcient and the motor
could be overheated.
Contact AIROFOG USA or an authorized
dealer for technical assistance
Cleaning
11

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Getting
Ready
Upon receipt of the ULV Cold
Fogger, remove from box and
inspect that the pieces are
accounted for and that there is
no visible damage to the fogger.
Use the correct power rating
from the identication plate.
If voltage and frequency
ratings used are beyond those
indicated, the appliance may
suffer serious damage and fail to
operate in the right way.
Inspection
1
3
2
7
4
5
6
8
9

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Operating the
Cold Fogger
• Remove the closure ring (5) and check the tank (6) is clean.
• Replace the power head (7), making sure the tank gasket (4) is
in place and return the closure ring (5) to its position.
• Pour the solution into the tank (6) then close the lling cap (8),
make sure the gasket (9) is in position.
• Before connecting the power plug (3) to a power socket, make
sure that:
• ow control knob (2) on close position
• switch (1) is set to the off position
• Aim the nozzle in the required direction and switch on the
appliance.
• Adjust ow control knob for the quantity of product to be
distributed.
• Once fogging is complete, close the control knob before switching
off the appliance.
• Disconnect the power plug from power socket.
• Remove residues of solution and empty tank, fogging with warm
water.
Prepping the Cold Fogger
Finished fogging
Make sure the power plug (3) is disconnected from the power
socket.
When using solution which creates foam, keep the foam from
penetrating into the power head (7) to damage the motor, in
any case the foam level should be kept lower than the PP lter.
Plan the job so that the fogger draws in the fog as little as
possible through its intake. We recommend starting towards
the end of your site and work your way towards the exit

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Extension Hose
for U260/ U120
57
• Use the Cold Fogger with more precision and control with the
extension hose (Compatible only with U260 / U120) to reach further
distance and harder to reach areas while using less solution.
Extention Hose
Pay attention not to kink or twist the extension solution tube
that sits within the extension hose itself. (57) .

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Applications &
Consumption
• Public hygiene such as in communities, hotels,
canteens, schools, ofces, banks, means of
transportation.......
• Disinfection in food industry
• Disinfection or application of vaccine in intensive
livestock
• Disinfection in greenhouse and mushroom
production
• pest control against ying and crawling insects
• Control of mildew and fungus
• Odor control
The appliance is tted with a standard needle dosage
control or an optional 5-position dosage control
for U260/U120. As the output varies according
to different chemicals and physical propertises of
the formulations, we advice that you do your own
metering of the output under prevailing conditions.
Universal Applications
Consumption
U260/ U120
(no extension hose)
1.3oz/min
2.7oz/min
5.0oz/min
8.1oz/min
10.1oz/min
11.8oz/min
12.8oz/min
13.5oz/min
1/4
1/2
3/4
1
1 1/4
1 1/2
1 3/4
2
Regulator
turns
Flow
(tested with water
U260/ U120
5pt Liquid Dosage Control
0oz/min
1.6oz/min
3.3oz/min
5.0oz/min
6.7oz/min
8.7oz/min
0
1
2
3
4
5
Regulator
position
Flow
(tested with water
U240/ U110
0.8oz/min
2.0oz/min
2.5oz/min
3.0oz/min
3.7oz/min
4.2oz/min
4.7oz/min
5.0oz/min
1/4
1/2
3/4
1
1 1/4
1 1/2
1 3/4
2
Regulator
turns
Flow
(tested with water

Airofog USA
15074 Aviation Loop Drive
Brooksville, FL 34604
USA
+1-352-593-5152
www.airofogusa.com
Optimizing the
Cold Fogger
• Before application, make sure you know the
required application time and
• quantity of substance to treat the area, as this will
make the job easier.
• The ideal condition for the suspension of the minute
droplets is around 250C temperature and 75% relative
humidity.
• During application, never leave the appliance
unattended.
Since a ne mist is difcult to be seen, usually it is better to calculate fogging time
and volume from the liquid ow rate rather than rely on visible indications.
An optimum distribution rate is 1.7oz of substance per minute approximately. To
establish the application time, rstly determining the total quantity of substance to
be applied, in accordance with the formula as below:
Recommendations
( m3 of area to be treated ) x ( oz of substance required for 1m3 ) = oz of substance
oz of substance
distribution in oz per minute
= distribution time in minutes
Distribution
This manual suits for next models
3
Table of contents
Other Airofog Insect Control Equipment manuals
Popular Insect Control Equipment manuals by other brands

Olimpia electronics
Olimpia electronics RT-52/HACCP quick start guide