<12005442 001>
Page 7 of 78
IEC 60950
Clause Requirement Test Result – Remark Verdict
TRF No.: I950___E TRF originator: FIMKO
1.7.8.4 Markings using figures .......................................:
Not used. N
1.7.9 Isolation of multiple power sources .....................:
Equipment designed for only
one connection to the mains. N
1.7.10 IT power system For Norway compliance has
to be evaluated during the
national approved.
N
1.7.11 Thermostats and other regulating devices Neither thermostats nor other
regulating devices provided. N
1.7.12 Language .............................................................:
Installation instruction and
markings are in English.
User’s Manual in English.
Versions of other languages
will be provided when
submitted for national
approval.
P
1.7.13 Durability The marking plate was
subjected to the permanence
of marking test. The marking
plate was rubbed with cloth
soaked with water for 15s and
then again for 15s with the
cloth soaked with petroleum
spirit.
After this test there was no
damage to the marking. The
marking on the label did not
fade. There was no curling of
the marking.
P
1.7.14 Removable parts No removable parts provided. N
1.7.15 Replaceable batteries No batteries provided. N
Language..............................................................:
1.7.16 Operator access with a tool..................................:
There are not any operator
accessible areas with a tool
defined.
N
1.7.17 Equipment for restricted access locations............:
dto N
2 PROTECTION FROM HAZARDS P
2.1 Protection from electric shock and energy hazards P
2.1.1 Protection in operator access areas P
2.1.1.1 Access to energized parts See below.