AES Proteam iX7 User manual

Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]
Proteam iX Inverter

Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]

-1 -
TABLE OF CONTENT
1. PREFACE …………...…………………………………………………………………………..…………....2
2. CARTON CONTENTS …………...……………………………………………………………….......5
3. OVERVIEW OF THE UNIT ……………………………………………………………..……………….……6
4. EXPLODED VIEW …………………………..……………………………………………..……………….……8
5. INSTALLATION AND CONNECTION …………………………..………..………..…………………10
5.1 Installation Illustration …………………………..………..…………………..…………….……10
5.2 Swimming Pool Heat Pumps Location ….…………..…………………..…………………10
5.3 How Close to Your Pool? ….…………..……………………………………....…………….……11
5.4 Swimming Pool Heat Pumps Plumbing ….…………………………....….…………….…11
5.5 Swimming Pool Heat Pumps Electrical Wiring ….………………....….………….……12
5.6 Initial Startup of the Unit….………………....….………………………………...……….……12
6. OPERATING THE UNIT ………………………………………………………………………….…….……13
6.1 LCD CONTROLLER INTERFACE….………………....….……………………………….......……14
6.2 BUTTON OPERATION INSTRUCTION….………………....….…………………….......……16
6.3 TIMER SETTING….………………..........…………...………..…….…………………….......……19
6.4 FORCED DEFROST MODE ….……………….........……..…….….………………….......……23
7. ERROR CODES ……………………………………………………………..……………………….…….……23
8. MAINTENANCE AND INSPECTION………………………………………..……………….…….……25
9. WIRING DIAGRAMS……………………………………………………………..……………….…….……31
10. CABLE SPECIFICATION…………………………………………….…………………..……….…….……34
11. WIFI / APP APPLICATION ………………………………..……….……….……..………….…….……35
READ THIS MANUAL CAREFULLY BEFORE OPERATING THE UNIT. DO NOT THROW IT AWAY.
RETAIN FOR FUTURE REFERENCE.
BEFORE OPERATING THE UNIT, ENSURE THE INSTALLATION HAS BEEN CARRIED OUT IN
ACCORDANCE WITH THESE INSTRUCTIONS. IF IN DOUBT PLEASE CONSULT YOUR LOCAL
DEALER.
Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]

-2 -
1. PREFACE
In order to provide our customers with quality, reliability and versatility, this product has
been made to strict production standards.
This manual includes all the necessary information about installation, debugging,
discharging and maintenance. Please read this manual carefully before you open or
maintain the unit.
The manufacture of this product will not be held responsible if someone is injured or the
unit is damaged, as a result of improper installation, debugging, or unnecessary
maintenance. It is vital that the instructions within this manual are adhered to at all times.
The unit must be installed by qualified personnel.
The unit can only be repaired by qualified installer centre , personnel or an authorized
dealer.
Maintenance and operation must be carried out according to the recomended time and
frequency, as stated in this manual.
Use genuine standard spare parts only.
Failure to comply with these recommendations will invalidate the warranty.
Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature
constant. For split type unit, The indoor unit can be Discretely hidden or semi-hidden to suit
a luxury house. Our heat pump has following characteristics:
a.Durable
The heat exchanger is made of PVC & Titanium tube which can withstand prolonged
exposure to swimming pool water.
b.Installation flexibility
The unit can be installed outdoors.
c.Quiet operation
The unit comprises an efficient rotary/ scroll compressor and a low-noise fan motor,
which guarantees its quiet operation.
d.Advanced controlling
The unit includes micro-computer controlling, allowing all operation parameters to be
set. Operation status can be displayed on the LCD wire controller. Remote controller can be
chosen as future option.
Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]

-3 -
WARNING
Do not use means to accelerate the defrosting process to clean,
other than those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources
(for example: open flames, an operating gas appliance or an operating electric heater.)
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
NOTE: The manufacturer may provide other suitable examples or may provide additional
information about the refrigerant odour.
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
The appliance shall be installed in accordance with national wiring regulations.
Before obtaining access to terminals, all supply circuits must be disconnected.
Spaces where refrigerant pipes shall be compliance with national gas regulations.
Servicing shall be performed only as recommended by the manufacturer.
The appliance shall be stored in a well-ventilated area.
All working procedure that affets safety means shall only be carried by competent persons.
Transport of equipment containing flammable refrigerants
Compliance with the transport regulations
Marking of equipment using signs
Compliance with local regulations
Disposal of equipment using flammable refrigerants
Compliance with national regulations
Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer's instructions.
Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the
equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will be
determined by local regulations.
Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]

-4 -
Caution & Warning
1. Please make sure that the unit and power connection have good earthing, otherwise may
cause electrical shock.
2. Directive 2002/96/EC (WEEE):
The symbol depicting a crossed-out waste bin that is underneath the appliance indicates
that this product, at the end of its useful life, must be handled separately from domestic
waste, must be taken to a recycling centre for electric and electronic devices or handed
back to the dealer when purchasing an equivalent appliance.
3. Directive 2002/95/EC (RoHs): This product is compliant with directive 2002/95/EC (RoHs)
concerning restrictions for the use of harmful substances in electric and electronic devices.
4. The unit CANNOT be installed near the flammable gas. Once there is any leakage of the
gas, fire can occur.
5. Make sure that there is circuit breaker for the unit, lack of circuit breaker can lead to
electrical shock or fire.
6. The heat pump is equipped with an over-load protection system. It does not allow for the unit
to start for at least 3 minutes from a previous stoppage.
7. Installation must be performed in accordance with local regulations by authorized person only.
8. USE SUPPLY WIRES SUITABLE FOR 75℃.
9. Caution: Single wall heat exchanger, not suitable for potable water connection.
Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]

-5 -
2. CARTON CONTENTS
Before starting the installation, please make sure that all following items are found inside
the box.
Carton Box
Item
Image
Quantity
Swimming pool heat
pump
1
Operation and
Installation Manual
1
Accessories
1 (Set)
Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]

-6 -
3. OVERVIEW OF THE UNIT
NO
iX7/ iX11
iX14
iX19/ iX21/ iX25
A
760
870
1020
B
544
653
708
C
283
307
318
D
332
356
391
E
356
380
415
F
110
115
137.5
G
520
620
725
H
740
850
1000
I
93.5
96.2
87.2
J
260
325
395
K
377
418
443
Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]

-7 -
NO
iX33/ iX40/ iX33T/ iX40T
A
1170
B
1389
C
192.5
D
427
E
469
F
96.5
G
560
Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]

-8 -
4. EXPLODED VIEW
MODELS: iX7/ iX11/ iX14/ iX19/ iX21/ iX25
1
Top cover
11
4-way valve assembly
2
Top metal frame
12
Right panel
3
Left panel
13
LCD controller pad
4
Fan bracket
14
Terminals block cover
5
Fan motor
15
Titanium heat exchanger
6
Fan blade
16
Compressor
7
Fan grill
17
Chassis
8
Back net
18
Reactor
9
Evaporator
19
Middle separation panel
10
Electrical control box assembly
20
Plastic front panel
Automated Environmental Systems, Unit B, Anglian Lane, Bury St Edmunds, IP32 6SR
01284 6587710 | [email protected]
This manual suits for next models
9
Table of contents
Other AES Inverter manuals