Aeroneb Go User manual

Instruction Manual


Table of Contents
Introduction....................................................... 1
Important Safeguards....................................... 2
Warranty ........................................................... 5
Classications and Markings............................ 6
Aeroneb®Go System Parts .............................. 7
Unit Assembly and Usage ................................ 7
Prior to Assembly.............................................. 7
Assembly/Functional Test................................. 8
How to Operate the Aeroneb®Go Nebulizer .... 9
Cleaning and Storing Your Aeroneb®Go........ 11
Troubleshooting Guide ................................... 14
Electromagnetic Susceptibility........................ 15
Specications ................................................. 17
Performance................................................... 18
Replacement Parts and Accessories.............. 20
Appendix 1: EMC tables................................. 21

This page has been intentionally left blank

1
INTRODUCTION
Be sure to read these instructions fully before use.
Thank you for purchasing the Aeroneb®Go Nebulizer. Certain
conditions such as asthma, COPD (chronic obstructive
pulmonary disease) and cystic brosis require that prescribed
liquid medication be turned into a ne mist, called an aerosol,
and then inhaled into the lungs. The Aeroneb® Go turns liquid
medication into an aerosol, which you can then inhale through
a mouthpiece or an aerosol mask into your lungs.
The Aeroneb® Go uses the unique OnQ™ Aerosol Generator,
which is unlike any other nebulizer technology available.
When you turn on your nebulizer, OnQ pumps liquid through
tiny holes in a wafer-thin metal plate to create a soft mist
aerosol.
The Aeroneb®Go, for use by paediatric and adult patients,
is intended to aerosolize physician-prescribed solutions for
inhalation that are approved for use with a general-purpose
nebulizer.
Designed with your needs in mind, the Aeroneb®Go is
portable, lightweight, compact and silent. The control module
operates with three (3) “AA” disposable or rechargeable
batteries (not included), or can alternatively be powered by
the AC/DC adapter.

2
IMPORTANT SAFEGUARDS
When you use electrical products, always follow basic safety
precautions. As with any electrical device take particular care
around children.
READ ALL WARNINGS AND INSTRUCTIONS BEFORE
YOU USE YOUR NEBULIZER
WARNING:
If this product is being used to treat a life threatening
condition, a backup device is necessary.
• As with any electronic device, this product may become
unusable due to an electrical outage, battery depletion,
or mechanical failure. We recommend that you have
spare batteries and have a backup device available to
you.
• The AC/DC adapter does not charge batteries.
• If you are using batteries and the green light is ashing,
your batteries are low. You may nish your treatment and
then change (or replace and recharge) the three “AA”
batteries immediately.
• Do not share your Aeroneb®Go Nebulizer with others.
It is intended for use by a single user. If more than one
person uses it, there is a risk of spreading infectious
illness.
• As with all electronic devices, it is recommended that the
product is unplugged when not in use.
• Adult supervision is required when this product is used by
children and individuals who require special assistance.
• Use this product only for physician-prescribed solutions
for inhalation as described in this manual.

3
• Do not use components or attachments that are not
recommended by Aerogen. Refer to the Replacement
Parts and Accessories section in this manual (page 20).
• Never operate this product if any of the parts are not
working properly or have been damaged.
• Do not use the Aeroneb®Go Nebulizer in the presence
of a ammable anaesthetic mixture with air, oxygen or
nitrous oxide. As with any electrical equipment, take care
when using the device in a potentially oxygen enriched
environment.
• Do not use the Aeroneb®Go Nebulizer with anaesthetic
breathing systems or lung ventilator breathing systems.
• Do not place or drop this product into water or any liquid
when it is plugged into a power source.
• Keep this product and cords away from heated surfaces.
• Be sure the device has been properly cleaned before
use to avoid possible contamination.
• If after proper cleaning it takes longer than 12 minutes to
deliver 3 mL of normal saline (0.9%), the Nebulizer Unit
should be replaced.
• The user should ensure that exhaled medication is
directed away from bystanders.
• Do not microwave any parts.
• By connecting the AC/DC adapter to the Aeroneb®Go
Control Module, the Aeroneb® Go Control Module and
batteries are not being charged.
• As with any cables keep all cables tidy to avoid tripping
or strangulation hazards and take particular care around
children.
WARNINGS CONTINUED:

4
• Do not nebulize alcohol-based drugs in an oxygen-rich/
high pressure environment.
• In event of loss of mains power, remove the AC/DC cable
from the control module and operate with batteries (refer
to page 9).
• Never clean your Nebulizer Unit with solvents, chemicals,
alcohol or abrasive cleaners.
• Do not use brushes, sharp tools or abrasive cloths that
could scratch or damage the surfaces.
• Do not clean parts in a dishwasher.
• Store your Aeroneb®Go in the carrying case.
• Do not store the Aeroneb®Go in a location where it is
exposed to direct sunlight, extreme heat or cold, dust or
water. Store out of reach of children.
• Follow local laws and recycling plans regarding disposal
or recycling of components, batteries and packaging.
• Before storing your Aeroneb® Go for an extended period,
remove the batteries from the Aeroneb® Go Control
Module and store them separately. If you do not take the
batteries out, they may leak and cause your nebulizer to
stop working.
WARNINGS CONTINUED:

5
WARRANTY
The Aeroneb®Go Control Module and AC/DC Adapter are
warranted for a period of two years from the date of purchase
against defects in manufacturing. The Aeroneb®Go nebulizer
unit is warranted for one year from date of purchase against
defects in manufacturing. All warranties are based on typical
usage.
The life of the Aeroneb®Go nebulizer unit has been validated
for use for 100 disinfecting treatments (boiling or baby
bottle steam steriliser). This is based on a minimum of one
year typical usage prole of 2 treatments per day and two
disinfecting treatments per week. The user should note that
any use in excess if this may result in reduced life of the
product.

6
CLASSIFICATIONS AND MARKINGS
The symbols that appear on the Aeroneb®Go Nebulizer and
its accessories are described in the table below:
Symbol Meaning
Attention, consult accompanying documents
Class II equipment per IEC/EN 60601-1
Type BF equipment per IEC/EN 60601-1. This label
applies to Aeroneb®Go nebulizer unit only
US
Classied by TUV with respect to electric shock, re
and mechanical hazards
SN Serial number
REF Model number
Manufacturer
Input
Output
DC Voltage
AC Voltage
Power On/Off
Fragile – Handle with care
Keep Dry
–20 oC
+60 oC
Transient storage temperature limits: -20°C to 60°C