2.Generaladvice
You haveboughtanairdryermadebyAERIALthusdecidingforaprovenquality
product"MadeinGermany". Ifthereareanyquestions, you will findsomeadvicein
thismanualhowtoeliminatesuchdifficultiesasquicklyaspossible.
ATTENTION:
Immediatelyafterreceipt,youshouldcheckyourairdryerfortransportdamage!In
thecaseof damage, youshouldinformtheforwarding agent, parcelservice, post
officeetc. accordinglyuponreceipt,andmakeanoteofit ontheforwarding
documents!
Ifatransport damageshouldbenoticedafterunpackingtheequipment,please
contactimmediatelyyourrespectivesellerorspecializeddealer.
Beforeputtingyourairdryerintooperationfortheveryfirsttime, theseinstructions
foroperationshouldbestudiedverythoroughly.Thus,you canmakesurethatthis
appliancewill operateperfectlyforalongperiod oftimesavingyourselves
unnecessaryrepairsandexpenses.
Inthecaseofmalfunction disconnectyourapplianceand ensurethatitisnot
connectedagainbytakingthemainsplugout ofthesocket.
Please, keepthedevicewrappinginordertobeabletosend thedevicesafefor
guarantee repair. Inordertosavespaceyouopensimplytheadhesivetapewitha
knifeand youfoldthecarton.
3.Modeoffunctioning
TheAD-/WT-airdryerisbuiltparticularlyforairdryingandlaundrydryinginclosed
rooms.
Thatdehumidifiercanprevent theformation ofcondensation, eliminatetoohighair
humidity,drylaundryandholdaspecificairhumidityconstant. Thetimewhichthe
dryerrequiresinordertoachieveaspecifichumidityortodryabulkoflaundry
dependsessentiallyontheenvironmentalconditions.Theattainablehumidityvalue
isequallydependent on theenvironmentalconditions.
TheAD-/WT-dehumidifierworksaccording tothecondensationprinciplewithheat
recovery. Thefan(Pos.2)suckthemoist airthrough acoolregister(evaporator,
Pos3).Theairbecomessofarchilledunderthepointofcondensationhere,that
themoistaircondenseaswaterand flowsthroughthecondensateoutlet. The
chilledand driedairiswarmedupatthecondenser(Pos.3)again. Duetotheheat
pumpeffect,theoutletairissomedegreeswarmerthanthesuckedroomair.
Usefulenergycan conductedupto3-foldoftheelectricalpowerconsumption.The
absolutemoistureofairisloweredcontinuouslybythecontinuouscirculationofthe
roomairthrough thedevice.Thesurplusmoistureisremovedsafelyand efficiently.