Aeotec NanoMote Quad User manual

30-09-2020 13:08
Pagina 1 van 5http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA003
Aeotec
NanoMote Quad
SKU: AEOEZWA003
Quickstart
This is a secure Wall Controller for Europe. To run this device please insert fresh 1 * LIR2450 batteries. Please make sure the internal battery is fully ch
1. Insert the LIR2450 battery.
2. Set the Z-Wave network main controller into learning mode (see Z-Wave network controller operating manual).
3. Pressing and holding a button for 3 seconds.
4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, import
distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use
equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sou
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart se
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not
in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave
device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of
security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Product Description
The NanoMote Quad is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wa
You can also activate a scene like sleep scene, movie scene and entertainment scene with it.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You ca
by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommend
the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inope
Pressing and holding a button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to
defaults if you short press the button within this 3 seconds.Please use this procedure only when the network primary controller is missing or otherwise inope

30-09-2020 13:08
Pagina 2 van 5http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA003
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
Installation
Open the cover
Insert your battery and close the cover
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate wi
devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave netwo
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Inclusion
1. Open the NanoMote
2. Insert the battery
3. Press the button on the NanoMote One twice
Exclusion
1. Press the button on the NanoMote One twice
Product Usage
LOW BATTERY ALARM FUNCTION
NanoMote Quad will send battery report to the lifeline group when button is triggered during the sleep mode. If the battery level of the NanoMote Quad is le
20%, the NanoMote Quad will send a low battery alarm to the main controller.
CHILD LOCK FUNCTION
Child Lock function. If enable the Child Lock function, the LED indicator will not be on when press down the button. To switch on/off the Child Lock function,
press and hold the button for 10 seconds, the LED indicator will be solid on in red. Then release the button, the LED indicator will be continuously stay in re
seconds. During this 2 seconds, please click the button once, the LED light will be blink fast in red for 2 seconds.
TESTING Z-WAVE NETWORK RANGE
Press and hold the button for 15 seconds, the LED light will be solid on in purple. Then release the button, the LED light will be stay in purple for 2 seconds,
2 seconds, please click the button once, it will start to test the Z-Wave network range and LED light will blink fast in purple. After finish the test, if the LED li
green, it refers to strong signal; if in blue, it refers to medium signal, and if in red, it refers to weak signal or no signal.
Tip: This function works only when NanoMote Quad has been included into a ZWave network.

30-09-2020 13:08
Pagina 3 van 5http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA003
BATTERY CHARGING
NanoMote Quad has an internal rechargeable battery that will run for three months under the normal use condition. The charger!s output should be a micro
terminal with the specification of output DC 5V.The LED color is red during the charging process, and it will turn to green if the charging is finished.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In orde
communicate with the device, a static controller Cis needed in the network. This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time
significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbo
Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static contro
controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses o
device. To wakeup the device please perform the following action: Pressing and holding a button for 3 seconds. Led will turn to green,which means Scene C
has been woken up.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing
Firmware-Update over the Air
This device is capable of receiving a new firmware 'over the air'. The update function needs to be supported by the central controller. Once the controller sta
update process, perform the following action to confirm the firmware update: With reference to Wake-up operation (VI.WAKE UP) and Z-Wave controller!s g
do OTA.
Association - one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a dif
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they a
related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will rece
same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number Maximum
Nodes Description
15 NanoMote Quad will send the central scene notification command and battery report comma
associated nodes if any button is triggered.
25 NanoMote Quad will send Basic Set command to the associated nodes if button 1 is presse
35 NanoMote Quad will send switch multilevel set, the multilevel start level change and multileve
level change command to the associated nodes if button 1 is pressed, hold and released, re
45 NanoMote Quad will send Basic Set command to the associated nodes if button 2 is presse
55 NanoMote Quad will sendswitch multilevel set, the multilevel start level change and multileve
level change command to the associated nodes if button 2 is pressed, hold and released, re
65 NanoMote Quad will send Basic Set command to the associated nodes if button 3 is presse
75 NanoMote Quad will sendswitch multilevel set, the multilevel start level change and multileve
level change command to the associated nodes if button 3 is pressed, hold and released, re
85 NanoMote Quad will send Basic Set command to the associated nodes if button 4 is presse
95 NanoMote Quad will sendswitch multilevel set, the multilevel start level change and multileve
level change command to the associated nodes if button 4 is pressed, hold and released, re
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock fu
enhanced features.

30-09-2020 13:08
Pagina 4 van 5http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA003
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be t
value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same
applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 32: Level of low battery
Define a battery level as the low battery.
Size: 1 Byte, Default Value: 20
Setting Description
10 - 50 when the value is 10% to 50%,it will send a low battery command.
Parameter 41: Enable send central scene notification.
Set of sending central scene notification or not.
Size: 1 Byte, Default Value: 1
Setting Description
0Disable
1Enable
Parameter 42: Setting the duration value of the command switch multilevel.
Setting the duration value of the command switch multilevel.
Size: 1 Byte, Default Value: 255
Setting Description
0 - 255 The higher the value,the long the duration value of the command switch multilevel
Parameter 43: Enable/disable the buzzer alarm when battery is running low.
Set the buzzer alarm or not when battery is low.
Size: 1 Byte, Default Value: 0
Setting Description
0Disable
1Enable
Technical Data
Dimensions 50 x 50 x 14 mm
Weight 26 gr
Hardware Platform ZM5101
EAN 1220000016118
IP Class IP 20
Voltage 3,6 V
Battery Type 1 * LIR2450
Device Type Wall Controller
Network Operation Portable Slave
Z-Wave Version 6.71.01
Certification ID ZC10-18036056
Z-Wave Product Id 0x0371.0x0002.0x0003
Frequency Europe - 868,4 Mhz
Maximum transmission power 5 mW

30-09-2020 13:08
Pagina 5 van 5http://manual.zwave.eu/backend/make.php?lang=en&sku=AEOEZWA003
Supported Command Classes
Association Grp Info
Association V2
Battery
Central Scene V3
Configuration
Device Reset Locally
Firmware Update Md V3
Manufacturer Specific V2
Powerlevel
Security 2
Security
Supervision
Transport Service V2
Version V2
Wake Up V2
Zwaveplus Info V2
Controlled Command Classes
Basic
Battery
Switch Multilevel V2
Explanation of Z-Wave specific terms
Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall
controllers.
Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.
Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
Inclusion — is the process of adding new Z-Wave devices into a network.
Exclusion — is the process of removing Z-Wave devices from the network.
Association — is a control relationship between a controlling device and a controlled device.
Wakeup Notification — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.
Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.
(c) 2020 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by Z-Wave
Europe GmbH. The product content is maintained by Z-Wave Europe GmbH , Supportteam, [email protected]. Last update of the product data: 2020-01-23
09:05:35
Other manuals for NanoMote Quad
2
This manual suits for next models
1
Table of contents
Other Aeotec Switch manuals

Aeotec
Aeotec AEOEZW140 User manual

Aeotec
Aeotec ZW139 User manual

Aeotec
Aeotec Smart Switch 7 User manual

Aeotec
Aeotec Dual Nano Switch Series User manual

Aeotec
Aeotec ZW116 User manual

Aeotec
Aeotec DSC18103-ZWEU User manual

Aeotec
Aeotec Dual Nano Switch ZW132 User manual

Aeotec
Aeotec AEOEZW116 User manual

Aeotec
Aeotec Smart Switch 6 User manual

Aeotec
Aeotec Smart Home Hub User manual