ADF Wed PROFINET / J1939 User manual

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 1 di 24
User Manual
Revision 1.001
En lish
PROFINET / J1939 - Converter
(Order Code: HD67610-A1)
for Website information:
www.adfweb.com?Product=HD67610
for Price information:
www.adfweb.com?Price=HD67610-A1
Benefits and Main Features:
Very easy to confi ure
Electrical isolation
Two PROFINET ports
Temperature ran e: -40°C/85°C (-40°F/185°F)
For others PROFINET products see also the followin link:
Converter PROFINET to
www.adfweb.com?Product=HD67600 (NME 2000)
www.adfweb.com?Product=HD67601 (Serial RS232)
www.adfweb.com?Product=HD67601 (Serial RS485)
www.adfweb.com?Product=HD67602 (Modbus Master RS232)
www.adfweb.com?Product=HD67602 (Modbus Master RS485)
www.adfweb.com?Product=HD67603 (Modbus Slave RS232)
www.adfweb.com?Product=HD67603 (Modbus Slave RS485)
www.adfweb.com?Product=HD67604 (PROFIBUS Master)
www.adfweb.com?Product=HD67605 (PROFIBUS Slave)
www.adfweb.com?Product=HD67606 (C N)
www.adfweb.com?Product=HD67607 (C Nopen)
www.adfweb.com?Product=HD67608 (DeviceNet Master)
www.adfweb.com?Product=HD67609 (DeviceNet Slave)
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
Other
Products

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 2 di 24
INDEX:
Pa e
INDEX 2
UPDATED DOCUMENTATION 2
REVISION LIST 2
WARNING 2
TRADEMARKS 2
SECURITY ALERT 3
EXAMPLE OF CONNECTION 4
CONNECTION SCHEME 5
CHARACTERISTICS 6
CONFIGURATION 6
POWER SUPPLY 7
FUNCTION MODES 8
LEDS 9
PROFINET 10
J1939 11
USE OF COMPOSITOR SW67610 12
NEW PROJECT / OPEN PROJECT 12
SET COMMUNICATION 13
RECEIVE FRAMES 14
SEND FRAMES 15
UPDATE DEVICE 16
MECHANICAL DIMENSIONS 18
ORDERING INFORMATIONS 19
ACCESSORIES 19
PLC CONFIGURATION 20
DISCLAIMER 23
OTHER REGULATIONS AND STANDARDS 23
WARRANTIES AND TECHNICAL SUPPORT 24
RETURN POLICY 24
UPD TED DOCUMENT TION:
Dear customer, we thank you for your attention and we remind you that
you need to check that the followin document is:
Updated
Related to the product you own
To obtain the most recently updated document, note the “document code”
that appears at the top ri ht-hand corner of each pa e of this document.
With this “Document Code” o to web pa e www.adfweb.com/download/
and search for the correspondin code on the pa e. Click on the proper
“Document Code” and download the updates.
To obtain the updated documentation for the product that you own, note
the “Document Code” (Abbreviated written "Doc. Code" on the label on the
product) and download the updated from our web site
www.adfweb.com/download/
REVISION LIST:
W RNING:
ADFweb.com reserves the ri ht to chan e information in this manual about
our product without warnin .
ADFweb.com is not responsible for any error this manual may contain.
TR DEM RKS:
All trademarks mentioned in this document belon to their respective
owners.
Revision
Date uthor Chapter
Description
1.000 18/09/2012
Dp All First Release
1.001 29/07/2013
Fl All Revision

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 3 di 24
SECURITY LERT:
G
ENER L
I
NFORM TION
To ensure safe operation, the device must be operated accordin to the instructions in the manual. When usin the device are required for
each individual application, le al and safety re ulation. The same applies also when usin accessories.
I
NTENDED
U
SE
Machines and systems must be desi ned so the faulty conditions do not lead to a dan erous situation for the operator (i.e. independent limit
switches, mechanical interlocks, etc.).
Q
U LIFIED
P
ERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications.
Qualified personnel are persons who are familiar with the installation, assembly, commissionin and operation of this equipment and who
have appropriate qualifications for their job.
R
ESIDU L
R
ISKS
The device is state of the art and is safe. The instrument can represent a potential hazard if they are inappropriately installed and operated
by personnel untrained. These instructions refer to residual risks with the followin symbol:
This symbol indicates that non-observance of the safety instructions is dan er for people to serious injury or death and / or the
possibility of dama e.
CE
CONFORMITY
The declaration is made by us. You can send an email to support@adfweb.com or ive us a call if you need it.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 4 di 24
EX MPLE OF CONNECTION:

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 5 di 24
CONNECTION SCHEME:
Figure 1: Connection scheme for HD67610-A1

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 6 di 24
CH R CTERISTICS:
The HD67610-A1 is a PROFINET / J1939 Converter.
It has the followin characteristics:
Up to 512 bytes in readin and 512 bytes in writin ;
Triple isolation between CAN - Power Supply, CAN - Ethernet, Power Supply - Ethernet.
Two-directional information between J1939 bus and PROFINET bus;
Mountable on 35mm Rail DIN;
Wide power supply input ran e: 8…24V AC or 12…35V DC;
Wide temperature ran e: -40°C / 85°C [-40°F / +185°F].
CONFIGUR TION:
You need Compositor SW67610 software on your PC in order to perform the followin :
Define the parameter of PROFINET line;
Define the parameter of CAN line;
Define the J1939 frames that the Converter can accept;
Define the J1939 frames that the Converter sends trou h the J1939 line;
Update the device.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 7 di 24
POWER SUPPLY:
The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below.
V C
VDC
Vmin Vmax Vmin Vmax
8V 24V 12V 35V
Consumption at 24V DC:
Device Consumption [W/V ]
HD67610-A1 3.5
HD67610-A1
Caution: Not reverse the polarity power

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 8 di 24
FUNCTION MODES:
The device has ot two functions mode dependin of the position of the ‘Dip2 of Dip-Switch A’:
The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal workin of the device.
The second, with ‘Dip2 of Dip-Switch A’ at “ON” position, is used for upload the Project and/or Firmware.
For the operations to follow for the updatin , see ‘UPDATE DEVICE’ section.
Accordin to the functionin mode, the LEDs will have specifics functions, see ‘LEDS’ section.
Warnin :
Dip1 of ‘Dip-Switch A’ must be at ON position for workin even if the Ethernet cable isn’t inserted.

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 9 di 24
LEDS:
The device has ot six LEDs that are used to ive information of the functionin status.
The various meanin s of the LEDs are described in the table below.
LED Normal Mode Boot Mode
1: ON [supply volta e ]
( reen)
ON: Device powered
OFF: Device not powered
ON: Device powered
OFF: Device not powered
2: MT [maintenance display]
(yellow)
ON: Maintenance Problem is present
OFF: No maintenance are present
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in pro ress
3: BF [bus fault] (red)
ON: The Ethernet connection is defective; the IP
address exists several times in the network; the own
NameOfStation exists several times in the network; no
IP address has been set
Flashing: At least one confi ured AR is no lon er in
the data exchan e
OFF: No errors are present
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in pro ress
4: SF [ roup error] (red) ON: At least one AR is not in the data exchan e
OFF: No errors are present
Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in pro ress
5: Ethernet1 Tx ( reen) Blinks when is transmittin Ethernet frames Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in pro ress
6: Ethernet2 Tx ( reen) Blinks when is transmittin Ethernet frames Blinks quickly: Boot state
Blinks very slowly (~0.5Hz): update in pro ress

Industrial Electronic Devices
ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com hone +39.0438.30.91.31
User Manual
PROFINET
/
J1939
Document code: MN67610_ENG Revision 1.001 Pa ina 10 di 24
PROFINET:
The PROFINET connection must be made usin Connector3 and/or Connector4 of HD67610-A1 with at least a Cate ory 5E cable. The
maximum len th of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to
100 Mbps. To connect the device to an Hub/Switch is recommended the use of a strai ht cable, to connect the device to a PC/PLC/other is
recommended the use of a cross cable.
Table of contents