ACU-RITE 200S READOUTS User manual

200S R
EADOUTS
REFERENCE MANUAL


200S i
200S Key Layout
200S Soft keys
There are multiple pages of soft key functions to select from the
operating modes. Use the LEFT/RIGHT arrow keys -4- to cursor
through each page. The page indicator in the Status Bar will show the
page orientation. The darkened page indicates the page you are
currently on.
1Display Area
2Soft keys
3Power Indicator light
4Arrow Keys: Use the UP/DOWN keys to adjust the
screen contrast.
5Axis Keys
6Numeric Keypad
7ENTER key
8CLEAR key
1Page Indicator
2Set Zero Indicator
Soft Key function (Page 1) Soft key
Opens on-screen help instructions.
Opens the Tool Table. Page 18 for Milling, and
page 36 for Turning.
Switches display between operating modes
Actual Value (Absolute) / Distance-to-Go
(incremental). See page 10.
Toggles between Set / Zero functions. Used
with individual axis keys (page 16).
Soft Key function (Page 2) Soft key
Opens the Datum form to set the datum for
each axis (page 20).
Opens the Preset form. This form is used to set
a nominal position. This is a Distance-To-Go
(Incremental) function (page 23).
Used to divide the current position by two. This
function is for Milling applications only
(page 26).
1
1
1
2
1
4
1
5
1
6
1
7
1
8
3
1
1
1
2

ii
Press to select the Circle Pattern, Linear
Pattern, Incline Mill, or Arc Mill table. This
function is for Milling applications only
(page 28).
This soft key toggles between radius and
diameter displays. This function is for Turning
applications only (page 41).
Soft Key function (Page 3) Soft key
Opens the Job Setup menu and provides
access to the Installation Setup soft key
(page 11).
Press when ready to identify a reference mark
(page 9).
Opens the Calculator functions for standard
math, trigonometry, RPM, and Taper for
Turning functions.
Toggles between inch and millimeter units
(page 11).
Soft Key function (Page 2) Soft key

200S iii
Readout Parameter Access Code
An access code must be entered before machine-related installation
parameters can be set or changed. This prevents inadvertent
adjustments to the installation setup parameters.
Access to Machine Parameter Operations
Refer to the Setup section also.
Begin by pressing the SETUP soft key.
Press the soft key INSTALLATION SETUP.
Press the access code numbers 8891 using the numeric key pad.
Press the ENTER key
The readout is now ready for machine parameter setting operations.
IMPORTANT!
The access code is 8891.
IMPORTANT!
To prevent setup parameters from being changed, remove
this page from the Reference Manual after initially setting
up the readout system. Retain this information in a safe
place for future use.

iv

200S v
Introduction
Software Version
The software version is shown on the initial power up screen.
200S
DRO axis availability.
Symbols within Notes
Every note is marked with a symbol on the left indicating to the
operator the type, and/or potential severity of the note.
200S Fonts
The following shows how soft keys, and hard keys are represented
within the text of this manual:
Soft keys - SETUP soft key
Hard keys - ENTER hard key
This User's Manual covers the functions of the 200S for
both milling, and turning applications. Operational
information is arranged in three sections: General
Operations, Mill Specific Operations, and Turn
Specific Operations.
The 200S DRO is available in two, and three axis form.
The 3 axis 200S DRO is used through out this manual for
illustration, and description of function keys.
General Information
e.g. on the behavior of the 200S.
Warning
e.g. when a special tool is required for a function.
Caution - Risk of electric shock
e.g. when opening a housing.

vi

200S vii
Hassle-Free Warranty
ACU-RITE Companies, Inc. is proud to offer the 3-Year Hassle-Free Warranty for all digital readout systems, vision readout
systems, and precision glass scales. This warranty will cover all of the ACU-RITE repair and replacement costs for any readout
or precision glass scale returned during the three (3) year warranty period. ACU-RITE will repair or replace the damaged
components - regardless of the product’s condition absolutely free, no questions asked. This warranty covers both materials,
and factory labor. In addition, authorized ACU-RITE service representatives will provide service labor (field service) for a period
of one (1) year at no charge. Notice of the claimed defect must be received by ACU-RITE within the warranty period.
This warranty applies only to products and accessories installed and operated in accordance with this reference manual.
ACU-RITE shall have no obligation, with respect to any defect, or other condition caused in whole or part by the customer’s
incorrect use, improper maintenance modification of the equipment, or by the repair, or maintenance of the product by any
person except those deemed qualified by ACU-RITE.
Responsibility for loss of operation, or diminished performance due to conditions beyond ACU-RITE’s control cannot be
accepted by ACU-RITE.
The foregoing warranty obligations are in lieu of all expressed or implied warranties. ACU-RITE Companies, Inc. shall not be
liable under any circumstances for consequential damages.

viii
Other manuals for 200S READOUTS
3
Table of contents