ACeevac SUC 81025 User manual

ACeevac
High Vacuum High Flow
Portable Suction Pump
SUC 81025
220 240 V~ 50 Hz
User Manual
CLEMENTS
Manual No. SUC 81025 008
Issue 3

User Manual
ACeevac High Suction Pump
Manual Number SUC 81025 008 ssue 3 2021-02
Copyright © 2021 CU Medical Australia Pty Ltd
The information in this manual was originated by, and is the exclusive
property of CU Medical Australia Pty Ltd. t is furnished for customer
information only, and is not an authorisation or licence to make this
product or to furnish this information to others.
Safety
Thank you for purchasing this Clements ACeevac High
Suction Pump.
For your safety it is imperative that this unit only be
operated by authorised personnel in accordance with the
instructions as described in this manual. Operated in this
way, the ACeevac High Suction Pump will provide the
standard of service specified.
Due to continual improvements in product design, the
ACeevac High Suction Pump may vary in detail from the
descriptions in this manual. n the event of further
questions please contact your local distributor or CU
Medical Australia direct.
Familiarise yourself with these Directions for Use
before operating this device.
Sponsor:
CU Medical Australia Pty Ltd
Unit U, 10 - 16 South St
Rydalmere NSW 2116 Australia
Phone: +61 2 9466 5300
Website: www.clements.net.au
CA-M srl
Via Ugo La Malfa 13
Frazione Pilastro
43013 Langhirano (PR)
taly
0123

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
3
Contents
Description......................................................................... 4
Specifications .................................................................... 5
Environmental Conditions .................................................. 6
Symbols. ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ... 7
Cautions ........ ..... ...... ..... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... 9
Controls and Operation.... ...... ..... ..... ..... ..... ...... ..... ..... ..... ... 10
sing FLOVAC Disposable Liners ..................................... 11
Cleaning .......... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ... 13
Spare Parts........................................................................ 15
Troubleshooting ......... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... ... 16
Wiring Diagram..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... ... 17
Diagnostic Setup...... ...... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... 18
Periodic Safety Check.... ..... ...... ..... ..... ..... ...... ..... ..... ..... ..... 20
Return for Repair . ..... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... .... 20
Emissions Guidance Table ................................................ 21
Immunity Guidance Table .................................................. 22
Immunity Guidance Table ................................................. 23
Separation Guidance Table .............................................. 24
Warranty... ...... ..... ..... ..... ...... ..... ..... ..... ...... ..... ..... ..... ...... .... 26

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
4 Description
Description
The Clements ACeevac High Suction Pump is a compact,
portable unit designed to suit the needs of hospitals, doctors’
surgeries and paramedics in providing a strong source of
suction for use in indoor environments where mains power is
available.
Identification
SUC 81025 ACeevac High Vacuum / High Flow Portable Suction
Pump
Intended Use
To provide a continuous vacuum source, within the stated
operating vacuum range, for the aspiration of fluids and
particulate matter in medical procedures carried out by
clinically trained and authorized personnel.
Contraindications
Before using the ACeevac, consult the instructions for use.
Failure to follow instructions in this manual could cause harm.
Do not use for thoracic or low vacuum drainage.
Do not use the ACeevac for suctioning of explosive, corrosive or
easily flammable fluids.
ACeevac is not suitable for MR . Do not place in the ACeevac
pump MR environments.
Pump Classifications
GMDN 63642
GMDN Term Surgical suc ion pump
GMDN Synonym Aspira or
Device Class Class IIa (Rule 11)
Elec rical Pro ec ion Class II
Pro ec ion Type BF Applied Par
S erilisa ion No supplied in s erile s a e
Anaes he ic Ra ing
NOT Ca egory AP
NOT Ca egory APG
Opera ion Mode Con inuous opera ion

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
5
Specifications
Specifications
Maximum Vacuum -80 kPa [-600 mmHg]
Maximum Flow 21 L/min ( hrough jar) 32 L/min (free air)
Mains Power
Requiremen
220 - 240 V~ 50 Hz 110 VA
S a us Indica or Green neon lamp in On/Off swi ch indica es power
available s a us
Pump Pis on ype
Fil er Disposable hydrophobic and bac erial fil er
BFE 99.9999%, VFE 0.027 micron
Collec ion Con ainer 1 li re au oclavable, sha erproof plas ic jar
Op ional 2 li re au oclavable, sha erproof plas ic jar
Op ional 1 li re disposable liner jar
Op ional 2 li re disposable liner jar
Overfill Pro ec ion Floa valve mechanism
Vacuum Con rol Needle valve
Gauge Bourdon ube ype. Dual scale.
Gauge Range 0 o -100 kPa gradua ed a 5 kPa
0 o -760 mmHg gradua ed a 50 mmHg
Weigh 3.6 kg
Dimensions 360L x 215W x 195H mm
S andard
Condi ions
25°C, Sea level, 100kPa
Mo or PSC AC mo or
Fuse F1.6A L 250V
Jar Classifications
GMDN 44943
GMDN Term Suc ion Sys em Canis er, Reusable
Device Class Class I (Rule 1)
S erilisa ion No supplied in s erile s a e

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
6 Environmental Conditions
Package Contents
The Clements ACeevac package contains:
• ACeevac portable suction pump
• Silicone 8 x 14 mm medical suction tubing; 18cm x2, 150cm x1
• 1 litre reusable collection jar with lid assembly
• 2-Pin AU plug to EC 320 power lead
• Disposable antibacterial/hydrophobic filter
• Stepped conical tubing connector
Environmental Conditions
Environmental conditions for operation, transportation and
storage are shown in the following table. n addition, for
vehicular transportation, the unit should be kept upright.
State Parameter Minimum Maximum
Opera ing Tempera ure 5ºC 35ºC
Humidi y 10% RH 93% RH
Barome ric Pressure 700 hPa 1060 hPa
Tempera ure -25ºC 70ºC
Humidi y 0% RH 93% RH
Barome ric Pressure 500 hPa 1060 hPa
Transpor and S orage
Al i ude 0 m 2000 m

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
7
Symbols
General warning
Consul user manual
Type BF Applied Par (suc ion cannula)
Insula ion Class II (double insula ion)
Hz Mains power frequency
Off
CE Mark in conformi y wi h CE MEDDEV direc ive
93/42/EEC and subsequen changes
Manufac urer
REF Model / Reference Number
LOT Lo / Ba ch Number
On
~Al erna ing curren
Symbols
0123

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
8 Symbols
SN Serial Number
Fragile
Rela ive Humidi y
Keep Cool / Keep ou of direc sunligh
Tempera ure Range
A mospheric Pressure Range
C-Tick Mark
Dispose of elec rical produc according o requiremen s
of WEEE direc ive
IP21
Degree of pro ec ion agains in rusion by body par s or
objec s an agains ingress by wa er.
1s Digi - Pene ra ion of Solids
2 = Pro ec ed agains solids > Ø 12.5 mm
2nd Digi - Pene ra ion of Liquids
1 = Pro ec ed ver ical dripping wa er
Symbols

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
9
Cautions
Usage
1. Use only for the specified Intended Use.
2. Do not use near flammable substances such as oxygen or
anaesthetic gases.
3. Home care use is restricted to home carers and physically and
mentally competent adults.
4. n home care use, keep accessories out of reach of infants as
small parts can present a choking hazard.
Fluids
1. Keep device clear of water and other fluids. Do not handle pump
with wet hands.
Electrical
1. Use only the supplied power cord.
2. Confirm that electrical rating of rating label matches that of the
mains power. Avoid the use of power boards and extensions.
3. Maintain clear access to the mains power outlet to facilitate
disconnection.
4. Place pump clear of patient and other electronic equipment.
5. When not in use, disconnect from power supply.
6. Do not pull cable to remove plug from mains power outlet.
General
1. Check the pump and fittings for damage before each use.
2. Do not use without the bacteria/hydrophobic filter correctly
fitted.
3. Switch off pump immediately if overflow float valve is actuated.
4. After use, clean and store away from heat, dust and sunlight.
Cautions

CLEMENTS
CLEMENTSCLEMENTS
CLEMENTS
10
Operation
1. Place the pump on a flat stable horizontal surface.
2. Connect a short length of silicone tubing from the jar “VACUUM”
port to the “ N” (or directional arrow symbol) side of the
bacterial/hydrophobic filter. Connect a short length of silicone
tubing from the other side of the filter to the pump inlet.
3. Connect the long silicone tubing to the jar “PAT ENT” port.
4. Connect supplied power cord to power socket at rear of pump.
Connect power cord to compatible mains outlet.
5. Press switch to turn on pump. (Press again to turn off.)
Controls and Operation
Pump Controls
Bac erial / Hydrophobic Fil er
» Mus ALWAYS be fi ed «
Vacuum Con rol
“IN” or Δ Side
of Fil er
“VACUUM” por
(above floa valve)
ON / OFF
Rocker
Swi ch
Vacuum Gauge
“PATIENT” Por
Connec Pa ien
Tubing
Power Inle
(a rear)
Table of contents
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual