ABB Relion REQ650 User manual

Relion® 650 series
Breaker protection REQ650 2.1 IEC
Product guide

Contents
1. Application..................................................................... 3
2. Available functions..........................................................5
3. Current protection........................................................ 12
4. Voltage protection........................................................ 13
5. Multipurpose protection................................................13
6. Secondary system supervision..................................... 13
7. Control......................................................................... 14
8. Logic............................................................................ 15
9. Monitoring.................................................................... 16
10. Metering......................................................................18
11. Human machine interface............................................18
12. Basic IED functions..................................................... 19
13. Station communication ...............................................19
14. Hardware description.................................................. 19
15. Connection diagrams.................................................. 22
16. Technical data............................................................. 23
17. Ordering for pre-congured IED...................................65
18. Ordering for Accessories............................................. 68
Disclaimer
The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any
errors that may appear in this document. Drawings and diagrams are not binding.
© Copyright 2016 ABB.
All rights reserved.
Trademarks
ABB and Relion are registered trademarks of the ABB Group. All other brand or product names mentioned in this document may be trademarks or registered
trademarks of their respective holders.
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1
2 ABB

1. Application GUID-3F024D79-D031-42DC-B0BC-1F3757B8D3E0 v3
Breaker protection REQ650 provides a standalone solution
for applications where synchrocheck controlled closing of the
circuit breaker is required, but the integration of the automatic
reclosing function into the main line protection IED is not
preferred or suitable. The advanced automatic reclosing,
synchronizing, synchrocheck and energizing check functions
of REQ650 provides an optimized standalone product.
REQ650 provides backup to the main protection with
redundant protection and control functions.
One pre-configured package has been defined for the
following application:
• A breaker bay connecting a transmission line to a
busbar, with back-up protection functions enabling
single or three phase trip (B11)
The backup protection is based on basic overcurrent and
voltage based functions. In line protection applications,
autoreclosing with or without synchrocheck is available.
The package is configured and ready for direct use. Analog
and control circuits have been pre-defined and other signals
need to be applied as required for each application. The pre-
configured IED can be changed and adapted to suit specific
applications with the graphical configuration tool.
Forcing of binary inputs and outputs is a convenient way to
test wiring in substations as well as testing configuration logic
in the IEDs. Basically it means that all binary inputs and
outputs on the IED I/O modules (BOM, BIM and IOM) can be
forced to arbitrary values.
Central Account Management is an authentication
infrastructure that offers a secure solution for enforcing
access control to IEDs and other systems within a substation.
This incorporates management of user accounts, roles and
certificates and the distribution of such, a procedure
completely transparent to the user.
The Flexible Product Naming allows the customer to use an
IED-vendor independent 61850 model of the IED. This
customer model will be used as the IEC 61850 data model,
but all other aspects of the IED will remain unchanged (e.g.,
names on the local HMI and names in the tools). This offers
significant flexibility to adapt the IED to the customers system
and standard solution
Description of B11
GUID-D9C6EAEB-A4EA-49BF-BE90-CC3CAF1CA476 v1
A breaker bay connecting a transmission line to a busbar,
with back-up protection functions enabling single or three
phase trip.
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1 Issued: June 2017
Revision: B
ABB 3

QB1QB2
QA1
QB9QC9
WA1
WA2
REQ650 B11 –Single breaker with single phase tripping
12AI (7I+5U)
CC RBRF
50BF 3I>BF EF4 PTOC
51N_67N4(IN>)
EF PIOC
50NIN>>
PH PIOC
50 3I>>
VN MMXU
MET UN
VN MMXU
MET UN
S SIMG
63
S SIML
71
Q CBAY
3 Control
WA2_VT
WA1_VT
LINE_CT
LINE_VT
SMP PTRC
94 1->0
SMB RREC
79 5(0→1)
SMP PTRC
94 1→0
SES RSYN
25 SC/VC
UV2 PTUV
27 2(3U<)
V MSQI
MET Usqi
VN MMXU
MET UN
V MMXU
MET U
FUF SPVC
U>/I<
DRP RDRE
DFR/SER DR
C MMXU
MET I
C MSQI
MET Isqi
ETP MMTR
MET W/Varh
CV MMXN
MET P/Q
Other Functions available from the function library
CCS SPVC
87 INd/I
CV GAPC
2(I>/U<)
BRC PTOC
46 lub
LC PTTR
26 q>
LOV PTUV
27
NS4 PTOC
46I2
ROV2 PTOV
59N 3U0
OV2 PTOV
59 3U>
OC4 PTOC
51_67 4(3I>)
IEC10000323-5-en.vsd
STB PTOC
50STB 3I>STB
LF PTTR
26 θ>
IEC10000323 V5 EN-US
Figure 1. Configuration diagram for configuration B11
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1
4 ABB

2. Available functions
Back-up protection functions
GUID-A8D0852F-807F-4442-8730-E44808E194F0 v11
IEC 61850 ANSI Function description Breaker
REQ650 (B11)
Current protection
PHPIOC 50 Instantaneous phase overcurrent protection 1
OC4PTOC 51_671) Four step phase overcurrent protection 1
EFPIOC 50N Instantaneous residual overcurrent protection 1
EF4PTOC 51N
67N2)
Four step residual overcurrent protection 1
NS4PTOC 46I2 Four step directional negative phase sequence overcurrent protection 1
LCPTTR 26 Thermal overload protection, one time constant, Celsius 1
LFPTTR 26 Thermal overload protection, one time constant, Fahrenheit 1
CCRBRF 50BF Breaker failure protection 1
STBPTOC 50STB Stub protection 1
BRCPTOC 46 Broken conductor check 1
Voltage protection
UV2PTUV 27 Two step undervoltage protection 1
OV2PTOV 59 Two step overvoltage protection 1
ROV2PTOV 59N Two step residual overvoltage protection 1
LOVPTUV 27 Loss of voltage check 1
Multipurpose protection
CVGAPC General current and voltage protection 1
1) 67 requires voltage
2) 67N requires voltage
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1
ABB 5

Control and monitoring functions
GUID-E3777F16-0B76-4157-A3BF-0B6B978863DE v13
IEC 61850 ANSI Function description Breaker
REQ650 (B11)
Control
SESRSYN Synchrocheck, energizing check and synchronizing 1
SMBRREC Autorecloser 1
QCBAY Apparatus control 1
LOCREM Handling of LRswitch positions 1
LOCREMCTRL LHMI control of PSTO 1
SLGAPC Logic Rotating Switch for function selection and LHMI presentation 15
VSGAPC Selector mini switch 20
DPGAPC Generic communication function for Double Point indication 16
SPC8GAPC Single Point Generic Control 8 signals 5
AUTOBITS AutomationBits, command function for DNP3.0 3
SINGLECMD Single command, 16 signals 4
I103CMD Function commands for IEC 60870-5-103 1
I103GENCMD Function commands generic for IEC 60870-5-103 50
I103POSCMD IED commands with position and select for IEC 60870-5-103 50
I103POSCMDV IED direct commands with position for IEC 60870-5-503 50
I103IEDCMD IED commands for IEC 60870-5-103 1
I103USRCMD Function commands user defined for IEC 60870-5-103 4
Secondary system supervision
CCSSPVC Current circuit supervison 1
FUFSPVC Fuse failure supervision 1
Logic
SMPPTRC Tripping logic 6
TMAGAPC Trip matrix logic 12
ALMCALH Logic for group alarm 5
WRNCALH Logic for group warning 5
INDCALH Logic for group indication 5
AND, GATE, INV,
LLD, OR,
PULSETIMER,
RSMEMORY,
SRMEMORY,
TIMERSET, XOR
Basic configurable logic blocks (see Table 1) 40–420
FXDSIGN Fixed signal function block 1
B16I Boolean 16 to Integer conversion 18
BTIGAPC Boolean 16 to Integer conversion with Logic Node representation 16
IB16 Integer to Boolean 16 conversion 18
ITBGAPC Integer to Boolean 16 conversion with Logic Node representation 16
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1
6 ABB

IEC 61850 ANSI Function description Breaker
REQ650 (B11)
TEIGAPC Elapsed time integrator with limit transgression and overflow supervision 12
INTCOMP Comparator for integer inputs 12
REALCOMP Comparator for real inputs 12
Monitoring
CVMMXN,
VMMXU, CMSQI,
VMSQI, VNMMXU
Measurements 6
CMMXU Measurements 10
AISVBAS Function block for service value presentation of secondary analog inputs 1
SSIMG Gas medium supervision 21
SSIML Liquid medium supervision 3
EVENT Event function 20
DRPRDRE,
A1RADR-
A4RADR,
B1RBDR-B8RBDR
Disturbance report 1
SPGAPC Generic communication function for Single Point indication 64
SP16GAPC Generic communication function for Single Point indication 16 inputs 16
MVGAPC Generic communication function for Measured Value 24
BINSTATREP Logical signal status report 3
RANGE_XP Measured value expander block 66
I103MEAS Measurands for IEC 60870-5-103 1
I103MEASUSR Measurands user defined signals for IEC 60870-5-103 3
I103AR Function status auto-recloser for IEC 60870-5-103 1
I103EF Function status earth-fault for IEC 60870-5-103 1
I103FLTPROT Function status fault protection for IEC 60870-5-103 1
I103IED IED status for IEC 60870-5-103 1
I103SUPERV Supervison status for IEC 60870-5-103 1
I103USRDEF Status for user defined signals for IEC 60870-5-103 20
L4UFCNT Event counter with limit supervision 30
TEILGAPC Running hour-meter 6
Metering
PCFCNT Pulse-counter logic 16
ETPMMTR Function for energy calculation and demand handling 6
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1
ABB 7

Table 1. Total number of instances for basic congurable logic blocks
Basic congurable logic block Total number of instances
AND 280
GATE 40
INV 420
LLD 40
OR 280
PULSETIMER 40
RSMEMORY 40
SRMEMORY 40
TIMERSET 60
XOR 40
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1
8 ABB

Communication
GUID-5F144B53-B9A7-4173-80CF-CD4C84579CB5 v13
IEC 61850 ANSI Function description Breaker
REQ650 (B11)
Station communication
LONSPA, SPA SPA communication protocol 1
ADE LON communciation protocol 1
HORZCOMM Network variables via LON 1
PROTOCOL Operation selection between SPA and IEC 60870-5-103 for SLM 1
RS485PROT Operation selection for RS485 1
RS485GEN RS485 1
DNPGEN DNP3.0 communication general protocol 1
DNPGENTCP DNP3.0 communication general TCP protocol 1
CHSERRS485 DNP3.0 for EIA-485 communication protocol 1
CH1TCP, CH2TCP,
CH3TCP, CH4TCP
DNP3.0 for TCP/IP communication protocol 1
CHSEROPT DNP3.0 for TCP/IP and EIA-485 communication protocol 1
MSTSER DNP3.0 for serial communication protocol 1
MST1TCP,
MST2TCP,
MST3TCP,
MST4TCP
DNP3.0 for TCP/IP communication protocol 1
DNPFREC DNP3.0 fault records for TCP/IP and EIA-485 communication protocol 1
IEC 61850-8-1 Parameter setting function for IEC 61850 1
GOOSEINTLKRCV Horizontal communication via GOOSE for interlocking 59
GOOSEBINRCV GOOSE binary receive 16
GOOSEDPRCV GOOSE function block to receive a double point value 64
GOOSEINTRCV GOOSE function block to receive an integer value 32
GOOSEMVRCV GOOSE function block to receive a measurand value 60
GOOSESPRCV GOOSE function block to receive a single point value 64
MULTICMDRCV/
MULTICMDSND
Multiple command and transmit 60/10
FRONT, LANABI,
LANAB, LANCDI,
LANCD, GATEWAY
Ethernet configuration 1
OPTICAL103 IEC 60870-5-103 Optical serial communication 1
RS485103 IEC 60870-5-103 serial communication for RS485 1
AGSAL Generic security application component 1
LD0LLN0 IEC 61850 LD0 LLN0 1
SYSLLN0 IEC 61850 SYS LLN0 1
LPHD Physical device information 1
PCMACCS IED configuration protocol 1
SECALARM Component for mapping security events on protocols such as DNP3 and IEC103 1
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1
ABB 9

IEC 61850 ANSI Function description Breaker
REQ650 (B11)
FSTACCS,
FSTACCSNA
Field service tool access via SPA protocol over ethernet communication 1
ACTIVLOG Activity logging parameters 1
ALTRK Service Tracking 1
SINGLELCCH Single ethernet port link status 1
PRPSTATUS Dual ethernet port link status 1
PRP IEC 62439-3 parallel redundancy protocol 1-P03
1MRK 505 358-BEN B
Breaker protection REQ650 2.1 IEC
Product version: 2.1
10 ABB