Step 2 On the wall of device mounting, place the device on
the wall for reference or refer to the mounting
dimension to mark two screw positions.
Step 3 Nail M3 screws on the wall and keep 2mm
interspace reserved.
Step 4 Hang the device on two screws and slide
downward, then tighten the screw to enhance
stability, mounting ends.
Wall-mounted Device Disassembling
Step 1 Power off the device.
Step 2 Unscrew the screw on the wall about 2mm.
Step 3 Lift the device upward slightly; take out the device,
disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power OFF operation: First, remove the power plug,
then remove the wiring section of terminal block. Please
pay attention to the above operation sequence.
Power Supply Connection
The device provides 3-pin power supply input terminal blocks
and supports 1 DC power supply input which
supports anti-reverse connection and
overload protection. Voltage range: 24VDC
(12~36VDC)
Checking LED Indicator
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table
below:
PWR
ON
PWR is connected and
running normally
OFF PWR is disconnected or
RUN
Blinking
The system is running
normally
OFF The system is not running or
System is running abnormally
Link/Act
(X1, G1-G4)
ON Ethernet port has established
a valid network connection
Blinking Ethernet port is in an active
OFF
Ethernet port has not
established valid network
connection
Specification
10Gigabit copper port 100/1000/10000BASE-T
(10Gigabit port)
(10Gigabit/Gigabit/100M
self-adaption)
Gigabit copper port 10/100/1000Base-T(X)
self-adapting RJ45 port, half/full
duplex self-
adaption or forced
working mode, support MDI/
MDI-X self-adaption
Indicator
Power indicator, running
indicator, interface indicator
(
)
Access terminal block 3-
pin 5.08mm pitch terminal
block
℃
℃
~