Page(s)
Safety Instructions and Electrical Safety
3 - 5
Electrical Safety
6
Feature
Diagram 7
Control Panel
Diagram 8
Installing your Air Conditioner
9 -11
Using your Air Conditioner
12 -21
Draining your Air Conditioner
22 –24
Cleaning your Air Conditioner
25
Start/End of Season Operations
26
Troubleshooting
27
Guarantee and Customer Services
28
Spare Parts
29
Specification
30
Notes
31
CONTENTS
2

Safety Instructions
Important note: Please read this booklet before installing and switching
on this appliance. The manufacturer assumes no responsibility for
incorrect installation and usage as described in this booklet.
•This model uses natural refrigerant gas as part of its cooling
system. This gas is known as R290 (Propane) and is environmentally
friendly but can be combustible. Care should therefore be taken
when handling or transporting the product to ensure that none of
the refrigeration circuit components are damaged.
•Do not obstruct ventilation openings on the appliance and never
insert your finger or any other object into the air outlet.
•Do not cover the appliance or place any object on the control
panel.
•The appliance must not be placed or rested on its power cord.
•Do not use adaptors or extension leads when connecting the
appliance to the electrical power supply.
•Do not use the appliance if the plug is damaged.
•Do not pull, twist or damage the power cable.
•Do not plug-in or un-plug the appliance with wet hands to prevent
electrical shock.
•Always store the unit in an upright position in order to maintain the
compressor working in a proper condition.
•This appliance can be used by childrenaged from 8 years and above
and persons with reduced physical, sensoryor mental capabilitiesor
lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children should not play
with the appliance.
3

Safety Instructions
•This appliance is designed to be used by adults, do not allow children
to play with the appliance.
•The appliance is intended for residential use only.
•When defrosting and cleaning the appliance, do not use any tools
other than those recommended by the manufacturing company.
•The appliance must be installed, used and stored in an area that is
greater than 13 m2.
•The appliance must be placed in an area without any continuous
sources of ignition (for example: open flames, gas or electrical
appliances in operation).
•R290/R32 is a refrigerant gas that complies with the European
directives on the environment. Do not puncture or damage any
part of the refrigerant circuit.
•If the appliance is installed, operated or stored in a non-ventilated
area, the room must be designed to prevent the accumulation of
refrigerant leaks.
•Individuals who operate or work on the refrigerant circuit must
have the appropriate certification issued by an accredited
organisation that ensures competence in handling refrigerants
according to a specific evaluation recognized by associations in the
industry.
•Maintenance and repairs that require the assistance of other
qualified personnel must be performed under the supervision of
an individual specified in the use of flammable refrigerants.
•Be aware that the refrigerants may not contain an odour.
•Compliance with national gas regulations shall be observed.
•The appliance shall be stored so as to prevent mechanical damage
from occurring.
4

Safety Instructions
•WARNING: System contains refrigerant under very high pressure.
The system must be serviced and repaired as recommended by the
equipment manufacturer and by qualified persons only.
•Do not use in the following locations: -
Next to a source of fire.
An area where oil is likely to splash.
An area exposed to direct sunlight.
An area where water is likely to splash.
Near a bath, shower or a swimming pool.
In a greenhouse.
An area where flammable gasses or liquids are present.
5

Electrical Safety
THIS APPLIANCE MUST BE PLUGGED INTO AN EARTHED SOCKET
•Before switching on, make sure that the voltage of your electricity supply is the
same as that indicated on the rating plate. This product is designed to operate
on 220 –240V AC; 50Hz. Connection to any other power source may damage the
unit.
•This product may be fitted with a non rewireable plug. If it is necessary to
change the fuse in the plug, the fuse cover must be refitted. If the fuse cover
becomes lost or damaged, the plug must not be used until a suitable
replacement is obtained.
•If the plug has to be changed because it is not suitable for your socket, or
becomes damaged in any way, it should be cut off and an appropriate plug fitted.
This should be carried out by a qualified electrician. The plug removed must be
disposed of safely, as insertion into a 13 Amp socket is likely to cause an
electrical hazard.
6

FEATURE DIAGRAM
For Customer Services & Spare Parts please call 0330 1230 597
Or visit us at www.zanussiheatingandcooling.uk
Front
1. Control panel
2. Handle (both sides)
3. Castors
4. Deflector
Rear
5. Intake grill
6. Air outlet grill
7. Intake grill
8. Power cable
9. Plug fixer
10. Condensation drain
(Dehumidification)
11. Condensation drain
(Heating)
7

CONTROL PANEL DIAGRAM
8

Exhausting Hot Air
In the COOL mode the appliance must be placed close to a window
or opening so that the warm exhaust air can be ducted from outside.
First position the unit on a flat floor and make sure there is a
minimum of a 45cm (18inch) clearance around the unit and ensure
this is within the vicinity of a plug socket.
1. Extend either side of the hose (Fig. 1) and screw on the hose
inlet (Fig. 2).
2. Extend the other side of the hose and screw it into the hose
outlet (Fig. 3)
3. Install the hose inlet into the unit (Fig. 4)
4. Affix the hose outlet into the window seal kit (Fig. 5+6)
Your window seal kit has been designed to fit most standard vertical
and horizontal windows; however, it may be necessary for you to
modify some aspects of the installation procedures for certain types
of windows.
INSTALLING YOUR AIR
CONDITIONER
9

Location
•The unit should be placed on firm ground to help minimise noise and
vibration. For safe and secure positioning, place the unit on a smooth,
level floor which is strong enough to support the unit.
•This unit has castors to aid placement but it should only be rolled on
smooth, flat surfaces. Use caution when rolling on carpeted and wooden
surfaces. Do not attempt to roll the unit over other objects.
•The unit must be placed within reach of a properly rated grounded
socket.
•Never place any obstacles around the air inlet or outlet of the unit.
•Allow at least 45cm of space around, above and away from the wall to
ensure the appliance works efficiently.
•The hose can be extended but it is best to keep it to the minimum length
required. Also ensure that the hose does not have any sharp bends or
sags.
INSTALLING YOUR AIR
CONDITIONER
10
This manual suits for next models
1
Table of contents
Other Zanussi Air Conditioner manuals
Popular Air Conditioner manuals by other brands

Fujitsu
Fujitsu Inverter ASBA30JFC operating manual

Toshiba
Toshiba RAS-M10SMUV-E installation manual

Daikin
Daikin FXLQ20MAVE Operation manual

Hitachi
Hitachi RAS-E24CAK instruction manual

CIAT
CIAT Magister 2 Series Installation, Operation, Commissioning, Maintenance

Bestron
Bestron AAC6000 instruction manual