SaunaMed FIR-1 User manual

1
FIR
-
1/2/3/4/6
LUX-1/2/3/4/6
FS-2/3/6
Consumer manual

2
Dear Customer,
Thank you for purchasing a SaunaMed Sauna.
Before using your new sauna please read this consumer’s manual carefully.
Contents
Preview
3
Operations
4
Specifications
5
Safety
7
Assembly and installation
9
Instructions for use
2
5
Ti
ps for use
34
Troubleshooting guide
35
Circuit diagram
39
Warranty
40

3
WARNING
DISCONNECT THE SAUNA FROM THE MAINS POWER SUPPLY
BEFORE CHANGING ANY PARTS OR CARRYING OUT A SERVICE.
All growth depends on sunlight. But 40% of the ultraviolet and the high energy rays of
the sun are harmful to the human body; the remaining 60% of the sun’s energy is
beneficial, comprising infrared rays.
Our infrared sauna uses these invisible (5.6-15μm) infrared rays to increase cell tissue
resonance, accelerate blood circulation and improve organic functions.
Infrared sauna therapy is becoming increasingly popular and accepted across the
medical profession, with more studies now supporting the science behind this exciting
new technology.
An infrared sauna can help relieve pain and improve wound healing and recovery by
increasing blood circulation. The increased metabolic rate experienced in an infrared
sauna actually burns calories as the body works to sweat. This aids fat burning,
improves cardiac fitness, strengthens the heart, helps eliminate toxins and improves
cellulite and general skin tone. A 30-minute session in an infrared sauna burns the
same calories as a 10-kilometer run.
The quality stereo system fitted in our saunas aids relaxation with sound therapy and
helps relieve stress.
Preview

4
Operating temperature range 5 - 40°C (ambient)
Humidity < 85%
Pressure 700 - 1060 hpa
Power supply 220V - 240 V
Frequency 50 Hz
EU Standard
Indoor use only: SaunaMed Saunas are primarily aimed at the domestic market.
Although a SaunaMed may be suitable for light commercial use, we do not recommend a SaunaMed
for heavy commercial use, for example, public gyms, spas, and leisure centres.
Please contact us for information on site-specific suitability and commercial grade saunas.
Do not install closer than 12.7mm (0.5 inches) to a wall.
Operating conditions
Features
Wooden construction
Digital microprocessor controlled
Temperature adjustable from 20°C – 60°C (5°C increments)
Adjustable dwell time from 0 to 60 minutes
Digital temperature sensor
Soft touch keypad
Long-life DuraWaveTM EMR NeutralTM pure ceramic FAR infrared heaters
Maintenance
Clean the sauna room with a soft wet cloth or sauna cleanser. NEVER use alcohol, benzene
or any other corrosive chemical to clean the unit.
No maintenance or service of electronic components is required unless faulty. Please consult
with the retailer or a qualified electrician if in doubt.
Transportation and storage
Avoid exposure to rain, snow, or other harsh environments during transport.
When in transit, handle the sauna unit with care.
Do not store in damp or humid environments.
Ensure that the unit is installed on a level surface. Uneven surfaces may result in pooling and
water ingress if the unit is installed in a bathroom; this can cause warping of the wooden
floor module.
If the surface on which the unit is installed is uneven and/or likely to be frequently exposed
to moisture, place the unit on levelling supports to raise it above the floor.
Operation
s

5
Model Dimensions (mm) Plans and elevations (same plan for FIR and LUX)
FIR-001 / LUX-001
(1-person
Classic/Luxury)
900 x 900 x 1900
FIR-1 LUX -1
FIR-002 / LUX-002
(2-person
Classic/Luxury)
1200 x 1000 x 1900
FIR-2 LUX -2
FIR-003 / LUX-003
(3-person
Classic/Luxury)
1500 x 1200 x 1900
FIR-3 LUX -3
Specifications
Dimensions

6
Model Dimensions (mm) Plans and elevations (same plan for FIR and LUX)
FIR-004 / LUX-004
(4-person
Classic/Luxury)
1800 x 1200 x 1900
FIR-4 LUX -4
FIR-006 / LUX-006
(6-person
Classic/Luxury)
1500 x 1500 x 1900
FIR-6 LUX -6
Specifications
Dimensions

7
Model Dimensions (mm) Plans and elevations (same plan for FIR and LUX)
FS-002
(3-person Full
Spectrum)
1100 x 900 x 1900
(w x d x h)
FS-003
(3-person Full
Spectrum)
1400 x 1250 x 1900
(w x d x h)
FS-006
(6-person Full
Spectrum)
1800 x 1500 x 1900
(w x d x h)
Specifications
Dimensions

8
Safety
General Safety Rules
All wiring to the sauna heater and accessories must be routed away from any direct
radiation from the sauna heater.
DO NOT place receptacles, flammables, and combustibles inside the sauna unit.
DO NOT spray water or any other liquids onto the interior or exterior surfaces of the sauna
unit.
DO NOT install any plumbing fixtures (such as taps, showers, steam generators etc.) in the
sauna unit.
DO NOT install any locking and/or latching system on the door, as the malfunction of these
parts can cause entrapment inside the sauna.
If located in a bathroom, ensure that the bathroom is well ventilated.
SaunaMed sauna units are only suitable for zone 3 or above (see diagram below). Installing
a sauna in a wet location with insufficient ventilation can result in electrical faults and
w
arranty invalidation.
Zone 1 Zone 2
Zone 0
Zone 2
0.6m
Zone 3
(Outside zones)
2.25m
3m

9
Safety Precautions
DO NOT dry clothes or leave towels in the sauna.
DO NOT touch the heating elements with bare hands or metal tools.
DO NOT touch the light when it is on.
DO NOT enter the sauna when wet.
DO NOT use the sauna if you have or suffer from any of the following conditions:
o Open wounds or serious burns
o Eye conditions
o Heat sensitivity
o Obesity
o Heart disease
o High and/or blood pressure
o Circulatory system problem
o Diabetes
DO NOT use the sauna if you are, or think you may be, pregnant.
DO NOT place pets in the sauna.
DO NOT use the sauna after drinking excessive alcohol.
This appliance is not intended for use by persons (including children) with reduced physical,
sensory, or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
Children should be supervised to ensure that they do not play with the appliances.
Be careful when using the appliance in places where there are combustible materials.
DO NOT use in an explosive atmosphere.
Be aware that heat may be conducted to combustible materials that are out of sight.
DO NOT leave the appliance unattended when it is switched on.
Safety
IF THE POWER SUPPLY CABLE IS DAMAGED, IT MUST BE REPLACED BY A QUALIFIED ELECTRICIAN OR
AS A COMPLETE ASSEMBLY AVAILABLE FROM THE MANUFACTURER OR ITS SERVICE AGENT.

10
Assembly and ins
tallation
Pre-assembly checklist
Items required for installation
1 x screwdriver
(included)
1 x spacer for wall
alignment (included)
1 x base panel
1 x front panel
1 x back panel
1 x LHS panel
(2 x LHS panels for FIR/LUX 6)
1 x RHS panel
(2 x RHS panels for FIR/LUX 6)
1 x door handle
1 x set of screws for
installing the door handle
2 x bench units
(4 x bench units for FIR/LUX 4/6)
Roof panel
30 to 60mins assembly
time
This manual suits for next models
12
Table of contents
Other SaunaMed Plumbing Product manuals
Popular Plumbing Product manuals by other brands

Weka
Weka 506.2020.00E ASSEMBLY, USER AND MAINTENANCE INSTRUCTIONS

Kohler
Kohler K-6228 Installation and care guide

UBERHAUS DESIGN
UBERHAUS DESIGN 75175017 Operator's manual

American Standard
American Standard DetectLink 6072121 manual

Uponor
Uponor Contec TS Mounting instructions

Pfister
Pfister Selia 49-SL Quick installation guide

Kohler
Kohler Centerset K-15240 Homeowner's guide

Viega
Viega Prevista Dry 8522.33 Instructions for use

Sanela
Sanela Lema SLP 59RB Instructions for use

Elkay
Elkay EDF15AC Installation, care & use manual

Hans Grohe
Hans Grohe AXOR Citterio E 36702000 Instructions for use/assembly instructions

baliv