Hot
Outlet
Cold
Step 2
70mm minimum wall cavity space is
required for this product.
Note: A vertical support may need to be
installed for correct positioning of the mixer.
Ensure front of vertical support is in line with
front of vertical framing.
Leave plastic covers in place during the installation.
IMPORTANT: Before you begin, turn off the water supply.
•
•
•
Step 3
Position mixer body against vertical support with
the front edge of mounting bracket flush with front
of the vertical support.
Secure mixer body to the vertical support with four
suitable screws, ensuring it is oriented square.
•
•
Step 1
It is recommended that the supplied non-return nipples are
installed in the hot and cold supply lines for cross flow
prevention. The arrows on the non-return nipples must
be installed in the directionof water flow.
Note: The nipples must be installed in an EASILY ACCESSIBLE LOCATION that allows for future
maintenance. They MUST NOT be connected directly to the mixer body.
If notalready present, isolation valves (not supplied) should be fitted prior to the non-return nipples
for ease of future maintenance.
The seal integrity of pipe joins are the responsibility of the installing plumber.
•
Step 4
Flush all pipe-work thoroughly prior to the next step.
Connect hot and cold supplies and outlet to mixer
body ensuring a good seal at each joint.
Leak test installation prior to closing wall cavity.
The seal integrity of pipe joins are the responsibility
of the installing plumber.
•
Step 5
Wall lining hole should be cut or finished as per the
dimension shown in the diagram on the right.
Optimum distance from front of vertical support to
finished wall surface = 23mm ± 10
•
•
•
•
Mixer Body Assembly
IMPORTANT: Please read all of the instructions before installation.
General:
•Methven recommends this product is installed by a licensed plumber in compliance with all
relevant regional regulations.
•Do not hydrostatic test the installation with this mixer installed. Damage to the ceramic cartridge
may occur.
•All pipe work must be thoroughly flushed prior to the installation of the mixer.
•In-line filters must be fitted on both hot and cold supplies to prevent foreign particles damaging
the ceramic cartridge.
•Do not remove the ceramic cartridge from the mixer when installing.
•After installation all connections must be checked for leaks.
•All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per
regional regulations.
•This mixer is not recommended for use in uncontrolled heating systems such as wet-backs or
solar heating units unless a suitable tempering valve is fitted.
•It is the responsibility of the installer to ensure a waterproof seal is achieved between the
product and mounting surface. If in doubt about the quality of the seal, remove the product and
reinstall using silicone to ensure a seal is achieved.
•Operating pressures above 500kPa/5 bar will require the installationof a pressure reducing valve.
Hex Key
Grub Screw
Non-return
Nipples
Handle
Faceplate
Covers
O-ring
Screws
Faceplate
Plastic Covers
Vertical framing
Vertical support
Flow Direction
70mm
min
Front edge of
mounting bracket
100mm ±2
23mm
±10