Falke clorofiLOG CFL2060 User manual

Manual
Digital Chlorophyll Content
Meter
clorofiLOG
CFL2060
Revision B
05/2023
MAN_CFL2060

CFL2060
Digital Meter of Chloro hyll Content
All rights reserved.
Falker Automação Agrícola Ltda.
Co ying by any means of this document or art of it without rior written
authorization is ex ressly rohibited.
Falker reserves the right to make changes to this document or the
equi ment without rior notice. The information contained in this document
is the most current at the time of ublication and is rovided to facilitate the
use of the equi ment.
Although every recaution has been taken in the re aration of this
document, Falker assumes no res onsibility for any errors or omissions, and
no liability is assumed for damages resulting from the use of the information
contained in this manual.
To make easy the com rehension and highlight im ortant as ects, some
information receive s ecial formating, as inidicated below.
Note:
Present some detail or better ex lanation of some oint of the text
ATTENTION:
Indicate oints that should be observed by user to a correct use and
maintenance of the device.
CAUTION:
Warn about situations that can ermanently damage the device or cause other serious damages.
www.falker.com.br
2 de 23

CFL2060
Digital Chloro hyll Content Meter
Índice
1 Introduction......................................................................................................4
2 The equi ment..................................................................................................5
2.1 Accessories.................................................................................................6
3 O eration..........................................................................................................6
3.1 First use......................................................................................................6
3.2 Basic o eration...........................................................................................7
3.3 Data acquisition..........................................................................................8
3.4 Data visualisation......................................................................................11
3.5 Manage.....................................................................................................12
3.6 Bluetooth..................................................................................................15
3.7 Settings....................................................................................................15
3.8 Internal GPS..............................................................................................16
3.9 Screens.....................................................................................................16
3.10 Falker Leaf – Visualisation and data analysis...........................................18
3.11 Data transfer...........................................................................................19
4 Basic maintenance...........................................................................................20
4.1 Battery charging........................................................................................20
4.2 Device cleaning.........................................................................................20
4.3 Software atualization................................................................................20
4.4 Another questions....................................................................................21
5 Technical s ecifications...................................................................................22
5.1 User Messages..........................................................................................22
5.2 Dimensional information...........................................................................23
5.3 Anatel homologation for equi ment CFL2060...........................................23
5.4 CE and FCC marking for equi ment CFL2060i...........................................23
3 de 23

CFL2060
Digital Meter of Chloro hyll Content
1 Introduction
The clorofiLOG – Digital Chloro hyll Content Meter – is an that allows the
user to identify the cro health condition in a sim le and direct form. The
chloro hyll content is ro ortional to fundamental nutrients, as nitrogen. By
using the clorofiLOG is ossible to identify and correct cro shortcomings
directly in field.
The measurement is done by o tical form, using scientific knowledge of
the light frequencies that chloro hyll rocesses best in hotosynthesis. With
exclusive technology, chlorofiLOG analyzes 3 light frequency bands in the
measurement, allowing a detailed analysis, taking into account the resence
of chloro hyll ty es A and B.
This manual covers all as ects related to the use of the equi ment and
guidelines for starting to use the Falker Leaf Web A lication and A , which
allows the visualization and analysis of collected data. However, this
document is not an agronomic manual, and does not include ost-
measurement actions related to the treatment of ICF.
Thank you for choosing Falker!
4 de 23

CFL2060
Digital Chloro hyll Content Meter
2 The equi ment
The equi ament is su lied in a rotection case, suitable for use in the
field. The folowing items are rovided:
•Eletronic device CFL2060
•Protection case
•Safety wrist stra
•Warranty term
•First use guide
•USB-A to USB-C cable
Figure 1: Device set
5 de 23

CFL2060
Digital Meter of Chloro hyll Content
ATENTION:
For being an accurate measurement device, the CFL2060 must be
trans orted carefuly. The case that is rovided was design to rotect the
equi ament when trans orted, allied with racticality of use. It is not a
ackage for cargo trans ort
2.1 Accessories
In addition to the items that come with the equi ment, the following
codes can be used to urchase accessories or re lacement items.
Table 1: Accessories Comercial Codes
FLK9020 USB-A to USB-C Cable
FLK9030 USB-A out ut charger
3 O eration
3.1 First use
To turn on the device, ress the on/off located on the left side of the
anel. To turn off, hold down the on/off button at least for five
seconds.
In the first use of the CFL2060, language and local time of o eration can
be set.
Figure 2: First use screens
To set time, GPS signal is required. If a message of no GPS signal is
dis layed, go to an outdoor lace. If it is not ossible to erform this
o eration, it will be ossible to set the time at another moment, in the
device settings menu. To start the use without setting time, turn off and
turn on the deviceso the the G s no signal message will be dis layed.
6 de 23

CFL2060
Digital Chloro hyll Content Meter
3.2 Basic o eration
Figure 3: User interface
The o eration of the device is done with the following buttons
and the screen, where the measurement values, warnings and user
information as the state of charge, memory occu ation and GPS signal are
dis layed.
When turning on the device, after an initialization screen, the main screen
a ears. The following information is dis layed on this screen: battery level
and GPS osition indication at the to . Also time indication (only when GPS is
receiving data) and memory usage are dis layed at the bottom.
The memory usage is shown by the icon (memory card) re resented by
the filling ste s, which indicate the memory usage.
The icon with 4 vertical bars indicates the device’s GPS signal strength. If
it has a signal, the main screen also indicates the time, based on data from
the GPS itself.
7 de 23

CFL2060
Digital Meter of Chloro hyll Content
Figure 4: Main screen
In the main screen, there are 5 o tions:
•Acquire: menu used to acquire new data.
•View: menu used to visualize acquired.
•Manage: menu that allows to set reference, add, edit or delete work.
•Bluetooth: menu that allows to enable or disable Bluetooth and
dis lay its status.
•Settings: menu of the device’s settings.
All the above menu offer their own o tions.
The navigation between the menu o tions is done by the following
buttons e . The button selects the choosen o tion. The button
returns to the revious screen.
3.3 Data acquisition
Use the “Acquire” menu to erform measurements.
After selecting the “Acquire” menu, the work selection screen will be
o ened, as shown in the figure 5 below.
Figure 5: Work selection
8 de 23

CFL2060
Digital Chloro hyll Content Meter
After selecting the desired work, the following screen will be dis layed:
Figure 6: “New day” or “Continue” screen
There is the o tion to continue one day work or start a new day. After
selection, the calibration screen will o en.
Figure 7: Calibration screen
To erform the calibration, the chamber must remain closed for u to 6
seconds, em ty without any leaf inside. Once the calibration is finished the
screen as shown in figure 8 below will o en.
Figure 8: Calibration confirm screen
9 de 23

CFL2060
Digital Meter of Chloro hyll Content
Note:
Device calibration will be requested whenever the user turns on the device
and starts the measurement rocess
After erforming the calibration rocedure, the equi ment will be ready
to erform measurements. A screen with the data of the last measurement
erformed will be resented to the user. If it is the first measurement, the
screen dis layed will be like the figure 9 below.
Figure 9: Measurement screen
Obtaining data with clorofiLOG is a quick and sim le rocedure.
With the measurement chamber o en, lace the leaf to be measured.
Kee the measurement chamber closed for 2 seconds, until the
equi ment emits two short bee s, indicating that the measurement has been
erformed. Release the chamber so that it returns to its starting osition.
The data obtained in the measurement, as well as its attributes, are
automatically stored in the device's memory. If the data has been obtained in
an erroneous way, the user can erase it and redo the measurement. In the
measurement screen, using the directional buttons, four resources can be
access.
Figure 10: Resources of the measurement screen
•See latest: feature used to check measurements taken at the current
oint.
•Close oint: ends measurements at the current oint.
10 de 23
This manual suits for next models
1
Table of contents