Enviroswim ES-3 Installation Guide
©Enviroswim 2022 ©Enviroswim 2022 V3.0AU
Adjust water balance
Lower by adding Hydrochloric Acid.
Raise by adding Sodium Bicarbonate.
Lower by diluting the pool water.
Raise by adding Calcium Chloride.
Lower by adding Hydrochloric Acid.
Raise by adding Sodium Bicarbonate.
Lower by diluting the pool water.
Raise by adding Pool Salt.
Do not use Cyanuric Acid (Stabliser) as this will interfere with the oxidising capability
of the Enviroswim system
Complete your warranty form at https://www.enviroswim.com/warranty-registration/
1. Balance the water as per above. Ensure all Enviroswim switches are set to OFF and variable controls (Ioniser
and ORP) at minimum (fully counter clockwise).
2. Set the left-hand switch (AUTO/OFF/MANUAL) on the Enviroswim
Control Box to MANUAL. Turn on the pool pump so that water is
flowing through the filtration system, including the Enviroswim
Oxidiser/Ioniser Wet Cell Housing and Ultrasonic Chamber. Make
sure that the Oxidiser/Ioniser Wet Cell Housing is filled with water.
3. Set the right-hand switch (ON/OFF) on the Enviroswim Control Box
to ON.
4. Turn the Oxidiser knob on the Enviroswim Control Box (under the
Oxidiser display) slowly clockwise until the Oxidiser display reads
between 14 - 16 Amps.
5. Turn the Ioniser knob to maximum. Run the unit for approximately
1 hour per 1,000 litres of water.
6. Perform chemical tests to determine the water balance readings for pH, ORP, alkalinity, copper and calcium
hardness then adjust accordingly (see the above balance water table).
Note: Copper Testing –the copper levels can only be checked when pH is in the correct range.
7. Once the copper levels are within the range of 0.2-0.4 ppm, set the timeclock for the appropriate run time
(1 hour per 10,000 litres) and adjust the Ioniser output to 20-40%.
8. Start-up is now complete. Remember every pool is different. Factors that will impact runtime are location,
bather load, season, type of cover and water temperature.
When can I use the pool?
When all the water levels are balanced correctly, as per the above table.
Plan layout of components
a. Check component dimensions.
b. Confirm sequence of components in water flow.
c. Check cable lengths for control box location.
d. Power Supply
2. Confirm additional materials required
a. Pipe fittings and Pipe adhesive
b. Cable ties
3. Tools
a. Pipe Saw
b. Drill and Bits
c. Screwdriver
What’s in the Box?
1 x Enviroswim Control Box
(power lead attached)
1 x Complete Wet cell housing
➢1 x Oxidiser Plate
➢1 x Copper/silver Electrodes
➢2 x O Rings and Locking Nuts
1 x Ultrasonic Chamber
4 x 40/50mm reducing bushes
1 x Installation Guide
1 x User Manual
1 x Copper test kit
Review
instructions next
page
IMPORTANT SAFETY INSTRUCTIONS
ATTENTION INSTALLER
This installation guide contains important information about the installation of this product. For complete instructions
on operation and safe use of this product refer to Enviroswim ES3 User Manual.
WARNING - READ AND FOLLOW ALL INSTRUCTIONS. IMPORTANT SAFETY INSTRUCTIONS
PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING –To reduce the risk of injury, do not permit children to use this product.
WARNING –When mixing acid with water, ALWAYS ADD ACID TO WATER, NEVER ADD WATER TO ACID.
WARNING –There are no serviceable parts in the control box. Return to Enviroswim for service.
WARNING –Do not operate electrolytic cell without proper flow or water circulation. A build-up of gases can
occur and cause hazardous conditions.
CAUTION –Use of chemicals other than those recommended may be hazardous. Follow the Chemical
Manufacturer’s Instructions.
CAUTION –This unit is for use with permanently installed pools. Do not use with storable pools. A permanently
installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for
storage. A storable pool is constructed so that it is capable of being readily disassembled for storage and
reassembled to its original integrity.
CAUTION –Some modern variable speed pumps have settings that produce inadequate water flow to either fill
the ES3 wet cell or create sufficient flow to affect the ES3 processes. Ensure the wet cell housing has adequate
flow of water and is full of water while the Enviroswim is operating.
READ ALL THESE INSTRUCTIONS
For advice phone 07 5655 6150 or email : info@enviroswim.com